ABB DW 1

Manuale utente ABB Timer settimanale a 1 canale Bluetooth DW 1

Model: DW 1

Introduzione

This manual provides comprehensive instructions for the installation, operation, and maintenance of the ABB Weekly Timer 1-Channel Bluetooth DW 1. Please read this manual thoroughly before using the device to ensure proper functionality and safety.

ABB Weekly Timer 1-Channel Bluetooth DW 1

Figura 1: Davanti view of the ABB Weekly Timer 1-Channel Bluetooth DW 1, showing the display, control buttons, and connection terminals.

Informazioni sulla sicurezza

  • L'installazione deve essere eseguita da un elettricista qualificato.
  • Scollegare l'alimentazione prima dell'installazione o della manutenzione.
  • Assicurarsi che il dispositivo venga utilizzato entro il volume specificatotage e le valutazioni correnti.
  • Non esporre il dispositivo a umidità o temperature estreme.

Prodotto finitoview

The ABB Weekly Timer DW 1 is a 1-channel digital switch designed for precise time-based control of electrical circuits. It features Bluetooth connectivity for convenient programming via a mobile application. This device is suitable for both commercial and residential applications, functioning as a built-in, installation, universal, or distributor timer.

Caratteristiche principali:

  • 1-Channel Digital Switching
  • Bluetooth Connectivity for Programming
  • Weekly Programming Capability
  • 8 Impostazioni programmabili
  • Compact Design for Row Installation

Configurazione e installazione

Importante: Installation should only be carried out by a qualified professional. Ensure the main power supply is disconnected before proceeding.

  1. Montaggio: Mount the timer securely on a DIN rail in a suitable electrical enclosure. The device is designed for wall mount and row installation.
  2. Cablaggio:
    • Connect the incoming phase (L) and neutral (N) wires to the designated input terminals. Refer to the wiring diagram on the device for correct connections.
    • Connect the load to the output terminals (Out 1). Ensure the load's current and voltage requirements do not exceed the timer's specifications (e.g., 10/16A, 250V).
  3. Accensione: Once wiring is complete and secure, restore power to the circuit. The display on the timer should illuminate.
  4. Configurazione iniziale: Follow the on-screen prompts or refer to the mobile application for initial time and date settings.

Istruzioni per l'uso

Connessione Bluetooth:

  1. Download the official ABB timer application from your smartphone's app store.
  2. Abilita il Bluetooth sul tuo smartphone.
  3. Open the ABB timer app and follow the instructions to search for and connect to your DW 1 timer. The timer's Bluetooth indicator will confirm a successful connection.

Programmazione:

All programming, including setting weekly schedules and specific ON/OFF times, is primarily done through the connected mobile application. The app provides an intuitive interface for managing up to 8 programmable settings.

  • Impostazione di ora e data: The app will guide you through setting the current time and date, which is crucial for accurate scheduling.
  • Creazione di programmi: Within the app, select "New Program" or similar option. Define the desired ON/OFF times, days of the week, and the output channel (if applicable, though this model is 1-channel).
  • Saving Programs: Ensure all changes are saved and synchronized with the timer via the app.

Sostituzione manuale:

The timer may feature physical buttons (C1, C2, etc.) for manual override. Consult the device's display or the mobile app for specific instructions on how to temporarily switch the output ON or OFF, overriding the programmed schedule.

Manutenzione

  • Pulizia: Clean the exterior of the timer with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Aggiornamenti del firmware: Periodically check the ABB timer application for any available firmware updates for your device. Keeping the firmware updated ensures optimal performance and access to new features.
  • Batteria (se applicabile): This device does not require user-replaceable batteries for operation.

Risoluzione dei problemi

ProblemaPossibile causaSoluzione
Timer display is off.Nessuna alimentazione elettrica.Check circuit breaker and wiring connections. Ensure 220V supply.
Load does not switch ON/OFF as programmed.Incorrect program settings; Manual override active; Wiring issue.Verify program settings in the app. Check for active manual override. Inspect load wiring.
Impossibile connettersi tramite Bluetooth.Bluetooth disabled on phone; App not open; Timer out of range.Ensure phone Bluetooth is on. Open the ABB app. Move closer to the timer. Restart phone/app.
L'ora/data non è corretta.Not synchronized with app; Power interruption.Connect to the app and synchronize time/date.

Specifiche

MarcaFIGURA
ModelloDW 1
Numero di parte2CSM222531R1000
MaterialePlastica
ColoreBianco
Dimensioni del prodotto (P x L x A)3.54" x 7.48" x 3.54"
Peso dell'articolo5.6 once
Voltage220 Volt
Numero di impostazioni8
Tipo di interruttore1 vie
Tipo di montaggioMontaggio a parete
UtilizzoUso commerciale e residenziale
Batterie richiesteNO

Garanzia e supporto

For warranty information and technical support, please refer to the official ABB website or contact your local ABB distributor. Keep your purchase receipt as proof of purchase.

Produttore: FIGURA

Documenti correlati - DW 1

Preview Guida alle soluzioni per una casa più intelligente di ABB: la prossima generazioneview
Esplora la guida completa alle soluzioni per una casa più intelligente di ABB, che illustra nel dettaglio l'automazione di nuova generazione per illuminazione, HVAC, sicurezza, efficienza energetica e altro ancora. Scopri i sistemi integrati per la vita moderna.
Preview Guida all'installazione del gateway ABB Ability™ Smart Sensor con Huawei E8372
Istruzioni dettagliate per l'installazione e la configurazione dell'ABB Ability™ Smart Sensor Gateway utilizzando un modem WiFi USB Huawei E8372. Scopri come connetterti, impostare i parametri di rete e verificare lo stato del gateway.
Preview Note sulla versione di ABB CoreSense M10 - Aggiornamenti software e guida all'installazione
Note di rilascio complete per ABB CoreSense M10, che descrivono in dettaglio le versioni software da 1.4.0.14 a 1.2.1.0, comprese nuove funzionalità, miglioramenti, problemi risolti e procedure di installazione passo passo per web e aggiornamenti USB.
Preview Manuale utente dell'interruttore orario digitale ABB DW
Manuale utente completo per gli interruttori orari digitali ABB serie DW, che descrive in dettaglio caratteristiche, installazione, funzionamento e programmazione. Include specifiche tecniche e linee guida di sicurezza.
Preview Modulo display ABB Welcome IP: specifiche e informazioniview
Dettagli completi sul modulo display IP Welcome di ABB, che includono connessioni, dati tecnici e conformità alle normative UE e FCC. Include i numeri di modello 51381CR e 51382CR.
Preview ABB free@home Sensor/Dimming Actuator Technical Manual (SDA-F-1.1.PB.1, SDA-F-2.1.PB.1)
Detailed technical manual for ABB's free@home sensor/dimming actuators, covering installation, commissioning, operation, and technical specifications for models SDA-F-1.1.PB.1 and SDA-F-2.1.PB.1.