Invacare 5410LOW

Manuale di istruzioni del letto completamente elettrico Invacare Low Homecare

Model: 5410LOW

1. Introduzione

This instruction manual provides essential information for the safe and effective use of your Invacare Low Homecare Full-Electric Bed, Model 5410LOW. This bed is designed to offer comfort and convenience in a homecare setting, featuring motorized adjustments for various bed positions. Please read this manual thoroughly before assembly, operation, or maintenance to ensure proper usage and to prevent injury or damage.

Important Note: This product is intended solely for homecare use and is NOT a hospital bed.

2. Informazioni sulla sicurezza

Your safety is paramount. Adhere to all warnings and instructions provided in this manual. Failure to do so may result in serious injury or damage to the product.

Precauzioni generali di sicurezza:

  • Always ensure the bed is placed on a stable, level surface.
  • Keep the area around the bed clear of obstructions.
  • Do not allow children or unauthorized persons to operate the bed controls.
  • Ensure all electrical cords are properly routed to prevent tripping hazards or damage.
  • Regularly inspect the bed for any signs of wear, damage, or loose components.
  • Non superare la capacità di peso massima di 350 libbre.
  • Questo prodotto contiene sostanze chimiche note allo Stato della California come causa di cancro e malformazioni congenite o altri danni all'apparato riproduttivo.

3. Caratteristiche del prodotto

The Invacare Low Homecare Full-Electric Bed is engineered with several features to enhance user comfort and safety:

  • Full-Electric Adjustments: Motorized controls allow for independent adjustment of the upper body, knee sections, and overall bed height.
  • Low Bed Profile: Designed to minimize the risk of injury from falls, offering a lower minimum height.
  • Costruzione durevole: Features reinforced steel sections and high-impact bed ends for extended product lifespan.
  • Funzionamento silenzioso del motore: Electrical components are designed for quiet performance, with a waterproof enclosed motor.
  • Waterproof Hand Pendant: Ergonomic and easy to clean, ensuring reliable operation.
  • Split-Spring Design: Facilitates easier delivery and assembly by a single person.
  • Capacità di peso: Supports individuals up to 350 lbs.
Invacare Low Homecare Full-Electric Bed in a home setting with a user and caregiver.

Figure 3.1: The Invacare Low Homecare Full-Electric Bed in use, demonstrating its integration into a home environment.

Diagram of Invacare bed frame highlighting features like double insulation, casters, thermal overload protection, 350lb weight capacity, washable electronics, crank through motors, and durable rubber pendant.

Figure 3.2: Key features of the Invacare bed frame, including safety and operational components.

4. Installazione e assemblaggio

The Invacare Low Homecare Full-Electric Bed is designed for straightforward assembly. It is recommended that two people perform the assembly for ease and safety.

Fasi di assemblaggio:

  1. Disimballare i componenti: Rimuovere con cautela tutti i componenti dall'imballaggio. Verificare che tutti i componenti elencati nella lista di imballaggio siano presenti.
  2. Montare la struttura del letto: Connect the head and foot sections to the main bed frame. The split-spring design allows for easier handling. Ensure all connections are secure.
  3. Installare i motori: Attach the motors to their designated positions on the bed frame.
  4. Collegare i componenti elettrici: Plug in the motor cables to the control box. Ensure all connections are firm and correctly seated. The electrical components are double-insulated for safety.
  5. Attach Hand Pendant: Connect the hand pendant to the control box.
  6. Posizione Letto: Move the assembled bed to its desired location. Ensure the locking casters on the head section and steering lock casters on the foot section are engaged to prevent unintended movement.
  7. Test iniziale: Plug the bed into a grounded electrical outlet. Use the hand pendant to test all functions (head up/down, knee up/down, bed height up/down) before placing a mattress or user on the bed.
Invacare bed frame showing the adjustable head and foot sections.

Figure 4.1: The adjustable bed frame, illustrating the head and foot sections.

Close-up of the Invacare bed's electrical connection panel with color-coded ports.

Figure 4.2: Detail of the electrical connection panel, showing color-coded ports for easy setup.

5. Istruzioni per l'uso

The Invacare Low Homecare Full-Electric Bed is operated using the ergonomic hand pendant.

Hand Pendant Functions:

Invacare hand pendant with buttons for adjusting bed positions.

Figure 5.1: The Invacare hand pendant for bed adjustments.

  • Head Section Adjustment: Press and hold the designated buttons to raise or lower the head section of the bed.
  • Knee Section Adjustment: Press and hold the designated buttons to raise or lower the knee section of the bed.
  • Regolazione dell'altezza del letto: Press and hold the designated buttons to raise or lower the entire bed frame vertically.
  • Combined Adjustments: Some pendants may offer buttons for simultaneous adjustment of head and knee sections for a comfortable seated position.

Release the button once the desired position is reached. The quiet motor ensures minimal disturbance during adjustments.

6. Manutenzione

Regular maintenance ensures the longevity and safe operation of your Invacare bed.

Pulizia:

  • Disconnect the bed from the power outlet before cleaning.
  • Wipe down the bed frame and bed ends with a damp panno e detersivo delicato. Evitare detergenti abrasivi.
  • The hand pendant and enclosed motor are waterproof and can be cleaned with a damp panno. Non immergere.
  • Ensure all surfaces are dry before reconnecting to power.

Ispezione:

  • Periodically check all electrical cords for fraying or damage.
  • Inspect all nuts, bolts, and fasteners for tightness. Tighten if necessary.
  • Ensure casters roll freely and locks engage properly.
  • Check for any unusual noises during operation, which may indicate a need for professional service.

7. Risoluzione Dei Problemi

This section addresses common issues you might encounter with your Invacare bed.

ProblemaPossibile causaSoluzione
Il letto non funziona.Power cord unplugged; circuit breaker tripped; loose electrical connection.Check power cord connection; reset circuit breaker; ensure all motor and pendant connections are secure.
One section (head/knee/height) does not move.Motor cable for that section is loose or disconnected; motor malfunction.Check the specific motor cable connection to the control box. If issue persists, contact support.
Bed makes unusual noises during operation.Componenti allentati; problema al motore.Inspect for loose bolts or frame components. If noise continues, discontinue use and contact support.
Potenza fuoritage.Nessuna alimentazione elettrica.In case of power failure, the bed features crank-through motors allowing for manual adjustment. Consult the specific instructions for manual operation if needed.

If you encounter a problem not listed here or if the suggested solutions do not resolve the issue, please contact Invacare Customer Support.

8. Specifiche

CaratteristicaDettaglio
Numero di modello5410BASSO
Dimensioni del prodotto (totale)88 inches (L) x 36 inches (W) x 9.5-20 inches (H, adjustable)
Sleep Surface Dimensions80 pollici (L) x 36 pollici (L)
Capacità di peso350 libbre.
Peso del prodotto170 libbre
ProduttoreInvacare

9. Garanzia e supporto

Invacare stands behind the quality of its products. For specific warranty details, please refer to the warranty card included with your product or visit the official Invacare websito.

Assistenza clienti:

For technical assistance, troubleshooting, or warranty inquiries, please contact Invacare Customer Support:

Telefono: 1 (800) 333-6900

Please have your model number (5410LOW) and purchase information ready when contacting support.

Documenti correlati - 5410BASSO

Preview Testiere del letto - Elenco dei componenti manuali, completamente/semi-elettrici 5301IVC
Elenco dettagliato dei componenti e informazioni di montaggio per le estremità del letto 5301IVC, un letto manuale, completamente elettrico o semi-elettrico. Include codici articolo, descrizioni e quantità per gruppo per i componenti della testata e della pediera.
Preview Invacare Homecare Beds Parts Catalog: Manual, Semi-Electric, Full Electric & Bariatric Models
Comprehensive parts catalog for Invacare Homecare Beds, including Manual, Semi-Electric, Full Electric, and Bariatric models like CareGuard. Find part numbers and specifications for Invacare beds.
Preview Invacare Bed Rail Entrapment Risk Notification Guide | Safety Information and Warnings
Comprehensive guide from Invacare detailing the risks of bed rail entrapment, safety precautions, benefits, and user guidelines for medical beds. Includes warnings and recommendations from the FDA.
Preview Invacare Medley Ergo and Medley Ergo Low User Manual
This user manual provides comprehensive instructions for the Invacare Medley Ergo and Medley Ergo Low medical beds. It covers essential safety guidelines, installation procedures, operational details, maintenance schedules, troubleshooting steps, and technical specifications to ensure safe and effective use of the medical beds.
Preview Manuale d'uso del letto ospedaliero Invacare Medley Ergo e Medley Ergo Low
Questo manuale utente fornisce istruzioni complete per i letti ospedalieri elettrici Invacare Medley Ergo e Medley Ergo Low. Contiene informazioni essenziali su sicurezza, installazione, funzionamento, manutenzione, risoluzione dei problemi e specifiche tecniche per garantire un utilizzo corretto e sicuro del prodotto.
Preview Manuale d'uso del letto Invacare Medley Ergo - Sicurezza, installazione, funzionamento e manutenzione
Manuale d'uso completo per i letti ospedalieri elettrici Invacare Medley Ergo e Medley Ergo Low. Include istruzioni per l'installazione, il funzionamento, le linee guida di sicurezza, la manutenzione, la risoluzione dei problemi e le specifiche tecniche.