Elitech SVP-7

Elitech SVP-7 7 CFM 2-Stage Smart Vacuum Pump Instruction Manual

Model: SVP-7 | Brand: Elitech

1. Informazioni sulla sicurezza

Please read and understand all safety warnings and instructions before operating the Elitech SVP-7 vacuum pump. Failure to follow these instructions may result in electric shock, fire, and/or serious injury.

2. Contenuto della confezione

Verificare che tutti gli articoli siano presenti nel pacco:

Elitech SVP-7 Vacuum Pump and included accessories

Image: Elitech SVP-7 Vacuum Pump and its included accessories, such as vacuum oil and the user manual.

3. Caratteristiche del prodotto

The Elitech SVP-7 Smart Vacuum Pump is designed with advanced features for efficient and reliable HVAC/R system evacuation:

Elitech SVP-7 Smart Vacuum Pump features overview

Immagine: Un overview of the Elitech SVP-7's smart features, including touchscreen, app control, and leak detection.

4. Impostazione

4.1 Initial Inspection and Oil Filling

  1. Unpack the vacuum pump and inspect for any shipping damage.
  2. Assicurarsi che l'interruttore di alimentazione sia in posizione "OFF".
  3. Remove the oil fill cap and fill the pump with the provided vacuum oil until the oil level is between the 'MIN' and 'MAX' marks on the sight glass.
  4. Riposizionare saldamente il tappo di riempimento dell'olio.

4.2 Connecting the Vacuum Gauge

For precise vacuum measurement, connect a compatible micron gauge to the pump or system:

Video: This video demonstrates the process of connecting a vacuum pump with a micron gauge for accurate readings during HVAC/R system evacuation.

4.3 Accensione

Connect the power cord to a suitable electrical outlet. Press the power switch to turn on the pump. The 4-inch touchscreen will illuminate, displaying the main interface.

Elitech SVP-7 Large Touch Screen Display

Image: The large touchscreen display of the Elitech SVP-7, showing real-time vacuum changes and operational data.

5. Istruzioni per l'uso

5.1 Funzionamento di base

  1. From the main screen, tap 'Measure' to view real-time vacuum data.
  2. Tap 'Run' to start the vacuum pump. The pump will begin evacuating the system.
  3. Monitor the vacuum level and other parameters on the touchscreen.
  4. Tap 'Stop' to halt the pump operation.

5.2 Controllo delle app mobili

The Elitech SVP-7 can be controlled and monitored remotely via the Elitech Tools mobile app (iOS/Android):

  1. Download and install the 'Elitech Tools' app from your device's app store.
  2. Ensure Bluetooth is enabled on your mobile device and the vacuum pump.
  3. Open the app, search for the SVP-7, and connect.
  4. From the app, you can remotely start/stop the pump, monitor vacuum levels, and export PDF reports.
Elitech SVP-7 Real-time Monitoring Via APP

Image: A technician monitoring the Elitech SVP-7 via the mobile app on a rooftop HVAC unit.

Video: This video demonstrates the features and usage of the Elitech PGW Wireless Digital Pressure Gauge, including app connectivity and data management.

5.3 Smart Leak Detection System

The integrated leak detection system provides a risk scale (0-100) to identify potential leaks:

Elitech SVP-7 Detect System Leakage Level

Image: The Elitech SVP-7 touchscreen displaying the system leakage level and other operational statuses.

5.4 Real-Time Vacuum Graph

The touchscreen and app display a real-time vacuum graph, allowing visual monitoring of the evacuation process:

Elitech SVP-7 Intelligent and Simple Interface

Image: The Elitech SVP-7's intelligent and simple interface, highlighting the vacuum graph and other smart features.

5.5 Automated Operation

The pump features automated functions for convenience:

Elitech SVP-7 Automatic Switch on and off

Image: The Elitech SVP-7 operating automatically, allowing a technician to monitor progress remotely.

6. Manutenzione

6.1 Cambio dell'olio

Regular oil changes are crucial for optimal pump performance and longevity. Change the vacuum pump oil after every 10-20 hours of operation or if the oil appears cloudy or discolored.

  1. Assicurarsi che la pompa sia spenta e scollegata dall'alimentazione.
  2. Posizionare un contenitore adatto sotto il tappo di scarico dell'olio.
  3. Remove the oil drain plug and the oil fill cap to allow the old oil to drain completely.
  4. Sostituire il tappo di scarico dell'olio.
  5. Refill with new industrial-grade ISO 46 vacuum pump oil until the level is between the 'MIN' and 'MAX' marks on the sight glass.
  6. Sostituire il tappo di riempimento dell'olio.

6.2 Pulizia generale

Keep the pump clean and free from dust and debris. Wipe down the exterior with a damp stoffa. Non utilizzare prodotti chimici o solventi aggressivi.

6.3 Conservazione

When not in use, store the vacuum pump in a dry, clean environment, protected from extreme temperatures and direct sunlight.

7. Risoluzione Dei Problemi

ProblemaPossibile causaSoluzione
La pompa non si avviaNessuna alimentazione, interruttore difettoso, problema al motoreCheck power connection, ensure switch is ON. If problem persists, contact support.
Scarse prestazioni del vuotoLow oil level, contaminated oil, system leak, clogged intakeCheck/change oil, use leak detection system, inspect connections, clean intake.
La pompa si surriscaldaInsufficient ventilation, prolonged operation, low oil levelEnsure adequate airflow, allow pump to cool, check oil level. Auto-shutdown will activate at 122°F.
Oil backflowPotenza fuoritage during operation, faulty solenoid valveThe solenoid valve is designed to prevent this. If it occurs, check valve function and system integrity.

8. Specifiche

CaratteristicaDettaglio
MarcaTecnologia d'élite
ModelloSVP-7
Portata7 CFM (3 Liters Per Second)
Vuoto estremo15 micron
Stages2-Stage
Potenza del motore3 / 4 HP
Fonte di alimentazioneElettrico con cavo
Peso dell'articolo38.4 libbre
Dimensioni del prodotto20.47 x 16.93 x 14.96 pollici
DisplaySchermo tattile da 4"
ConnettivitàBluetooth (Mobile App Control)
Caratteristiche di sicurezzaSolenoid Valve, 122°F Auto-Shutdown
Elitech SVP-7 Vacuum Pump Specifications

Image: A detailed graphic outlining the technical specifications of the Elitech SVP-7 vacuum pump.

9. Garanzia e supporto

Elitech products are designed for reliability and performance. This product comes with a standard manufacturer's warranty against defects in materials and workmanship. For specific warranty terms and conditions, please refer to the warranty card included in your package or visit the official Elitech websito.

For technical support, troubleshooting assistance, or service inquiries, please contact Elitech customer service through the contact information provided in your user manual or on the Elitech website. Our dedicated support team is available to assist you.

You can also find additional resources, FAQs, and product updates on the Elitech websito: Negozio Elitech

Documenti correlati - SVP-7

Preview Manuale d'uso del rilevatore di corona Elitech WJL-6000S
Manuale utente per il rilevatore di corona Elitech WJL-6000S, che fornisce istruzioni dettagliate sul funzionamento, il rilevamento, la risoluzione dei problemi e la manutenzione per il rilevamento delle perdite di refrigerante in vari sistemi.
Preview Manuale utente del rilevatore di perdite alogeno Elitech HLD-200
This user manual provides comprehensive instructions for operating and maintaining the Elitech HLD-200 Halogen Leak Detector. It covers technical specifications, operation procedures, leak detection methods, troubleshooting, and maintenance tips for effective use in refrigeration and HVAC systems.
Preview Manuale dell'utente del rilevatore di perdite di refrigerante a infrarossi serie Elitech ILD
Manuale utente completo per i rilevatori di perdite di refrigerante a infrarossi della serie Elitech ILD (ILD-100, ILD-200, ILD-300), che illustra specifiche, funzionamento, manutenzione e caratteristiche. Scopri come rilevare efficacemente le perdite di refrigerante con questo dispositivo avanzato.
Preview Manuale utente del rilevatore di perdite a infrarossi Elitech ILD-100/ILD-200/ILD-300
Manuale utente per i rilevatori di perdite di refrigerante a infrarossi della serie Elitech ILD (ILD-100, ILD-200, ILD-300). Fornisce informazioni dettagliate su funzionamento, specifiche, caratteristiche e manutenzione per un rilevamento accurato delle perdite di refrigerante.
Preview Manuale utente del rilevatore di perdite a diodo riscaldato e a infrarossi Elitech IR-200
Manuale utente completo per Elitech IR-200, un rilevatore di perdite a doppio sensore con tecnologia a infrarossi e diodo riscaldato. Scopri le specifiche, il funzionamento, la manutenzione e le funzionalità per la rilevazione delle perdite di refrigerante.
Preview Collettore digitale Elitech MS-100: manuale utente e specifiche
Guida completa al collettore digitale Elitech MS-100, che ne illustra caratteristiche, specifiche tecniche, funzionamento, istruzioni di sicurezza e risoluzione dei problemi. Scopri come utilizzare il dispositivo per misurazioni di pressione e temperatura, test di tenuta, processi di vuoto e registrazione dei dati con l'app Elitech Tools.