1. Introduzione
Thank you for choosing the Elitech ETC-3000A Digital All-Purpose Temperature Controller. This device is designed for precise temperature management in various applications, offering reliable cooling, defrosting, and fan control functions. Please read this manual thoroughly before installation and operation to ensure correct usage and optimal performance.
Caratteristiche principali:
- Stable and reliable performance, approved for Electromagnetic Compatibility (EMC) testing.
- Easy and convenient parameter setting via a copy card.
- Limited input value to prevent misoperation.
- Multiple defrosting and fan management options.
- Versatile output functions: cooling, defrosting, and fan control.
2. Informazioni sulla sicurezza
Per garantire un funzionamento sicuro ed evitare danni al dispositivo o lesioni, osservare le seguenti precauzioni di sicurezza:
- Scollegare l'alimentazione prima dell'installazione, del cablaggio o della manutenzione.
- Garantire l'alimentazione voltage corrisponde ai requisiti del controller (110 V CA).
- Non esporre il controller all'acqua o a umidità eccessiva.
- Avoid installing the controller in areas with strong electromagnetic interference.
- Tutti i cablaggi devono essere eseguiti da un elettricista qualificato, nel rispetto delle normative elettriche locali.
- Do not attempt to repair or modify the controller yourself. Contact qualified service personnel.
3. Prodotto finitoview
3.1 Descrizione del pannello frontale
The front panel features a digital display for temperature readings and status indicators, along with control buttons for setting parameters.

Figura 3.1: Fronte view of the Elitech ETC-3000A Temperature Controller, displaying current temperature and control buttons.

Figure 3.2: Dimensions of the Elitech ETC-3000A Temperature Controller.

Figure 3.3: Operational icons for Cooling, Defrost, Fan, and Copy Card functions.
3.2 Pannello posteriore e terminali di cablaggio
The rear panel houses the wiring terminals for power input, sensor connections, and output relays for controlling external devices.

Figura 3.4: Posteriore view of the controller with wiring terminals and a port for the copy card.
4. Installazione
4.1 Montaggio
The ETC-3000A is designed for panel mounting. Ensure adequate space for ventilation and access to wiring terminals. Cut an opening of appropriate size in the panel and secure the controller using the provided clips or mounting hardware.
4.2 Schema elettrico
Refer to the following diagram for correct wiring connections. Incorrect wiring can damage the unit or connected equipment.

Figure 4.1: Detailed wiring diagram for the ETC-3000A controller.
- Terminali 1-4: Relè di uscita per compressore, sbrinamento e ventola.
- Terminali 5-6: Power input (110V AC).
- Terminali 7-8: Collegamento della sonda della temperatura ambiente.
- Terminale 9: Collegamento sonda di sbrinamento.
- Copia porta chiave: For parameter copying.
5. Configurazione e funzionamento
5.1 Accensione
After completing all wiring, apply power to the controller. The display will show the current temperature measured by the room temperature probe.
5.2 Impostazione della temperatura
- Premere il tasto IMPOSTATO button once. The display will flash the current set temperature.
- Utilizzare il Up (▲) O Giù (▼) per regolare la temperatura desiderata.
- Premere il tasto IMPOSTATO button again to confirm and save the new setting.
5.3 Configurazione dei parametri
Advanced parameters for cooling differential, defrost cycles, fan operation, and more can be accessed and adjusted through a dedicated menu. Refer to the detailed parameter list in the full technical manual for specific codes and ranges. Parameters can also be set and copied using a copy card for quick configuration across multiple units.
6. Modalità operative
6.1 Modalità di raffreddamento
When the measured temperature rises above the set temperature plus the cooling differential, the compressor relay activates to initiate cooling. It deactivates when the temperature drops to the set point.
6.2 Modalità di sbrinamento
The controller supports various defrosting modes (e.g., timed defrost, manual defrost). During defrost, the defrost relay activates, and the compressor typically turns off. The defrost cycle duration and frequency are configurable parameters.
6.3 Fan Management
The fan output can be configured to operate continuously, only during cooling, or to turn off during defrost cycles, depending on the application requirements.
7. Manutenzione
Regular maintenance ensures the longevity and accurate operation of your temperature controller.
- Pulizia: Pulire il pannello frontale con un panno morbido, damp panno. Non usare detergenti abrasivi o solventi.
- Ispezione: Controllare periodicamente i collegamenti elettrici per verificarne la tenuta e l'eventuale presenza di segni di usura o corrosione.
- Controllo del sensore: Ensure temperature probes are clean and securely placed.
8. Risoluzione Dei Problemi
This section addresses common issues you might encounter with the ETC-3000A controller.
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Il display mostra "HHH" o "LLL" | Temperature probe error (open circuit or short circuit) or out of range. | Check probe connection. Replace probe if damaged. Ensure temperature is within operating range. |
| Il controller non si accende | Nessuna alimentazione o cablaggio errato. | Verify power connection and voltage. Check wiring against diagram. |
| Compressor/Fan not activating | Incorrect temperature settings, parameter errors, or faulty wiring to the load. | Review set temperature and differential. Check relevant parameters. Inspect wiring to compressor/fan. |
| Lo sbrinamento non si avvia | Defrost parameters incorrectly set or defrost probe issue. | Check defrost cycle parameters (duration, interval). Verify defrost probe connection. |
9. Specifiche
| Modello: | ETC-3000A |
| Alimentazione elettrica: | 110 V CA |
| Tipo di visualizzazione: | Digitale |
| Temperatura di esercizio: | 20°C (Note: This is likely an example, actual range depends on probe) |
| Funzioni di output: | Cooling, Defrosting, Fan |
| Batterie richieste: | NO |
| Colore: | Bianco |
| Produttore: | Tecnologia d'élite |
| Codice UPC: | 781454242726 |
Note: The operating temperature of 20°C listed in the specifications is likely a default or example value. The actual measurable temperature range will depend on the specific temperature probe connected to the controller. Please refer to the probe's specifications for its operational range.
10. Garanzia e supporto
Elitech products are manufactured to high-quality standards and are warranted against defects in materials and workmanship. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Elitech websito.
Assistenza clienti:
For technical assistance, troubleshooting, or service inquiries, please contact Elitech customer support through their official websito o le informazioni di contatto fornite nella confezione del prodotto.