1. Introduzione
This manual provides essential information for the safe and effective installation, operation, and maintenance of your Okin JLDQ.10.435.250I recliner bed actuator motor. Please read these instructions thoroughly before proceeding with installation or use to ensure proper function and longevity of the product.
2. Prodotto finitoview
The Okin JLDQ.10.435.250I is a refined linear actuator motor designed for recliner beds and power lift chairs. It serves as a direct replacement for specific Okin JLDQ series motors. The actuator motor set includes one motor unit and two connectors: a 5-pin round plug for the switch hand control and a 2-pin square plug with a clip for the power supply.

Image 2.1: The Okin JLDQ.10.435.250I recliner bed actuator motor.

Image 2.2: Close-up of the 2-pin power supply plug and 5-pin recliner switch plug.
3. Specifiche
| Caratteristica | Dettaglio |
|---|---|
| Modello | JLDQ.10.435.250I |
| Aspetto | Nero (PA), Bianco argento (Alluminio) |
| Colpo | 250 millimetri |
| Dimensioni minime (restringimento) | 435 millimetri |
| Maximum Dimensions (Extended) | 685 millimetri |
| Carico (forza di spinta) | 1000 N |
| Carico (forza di trazione) | 1000 N |
| Frequenza di funzionamento | Acceso 1 min / Spento 8 min |
| Potenza in ingresso | 24V === 50W (as per label) |
| Numero di serie Esample | Q21053376 00006 |

Image 3.1: Product label showing model number JLDQ.10.435.250I e dati tecnici.
4. Compatibilità
This Okin JLDQ.10.435.250I motor is designed as a replacement for the original Okin JLDQ motor, model JLDQ.10.435.250I. It can also replace the following models, though minor differences may exist that do not affect general use:
- JLDQ.19B.435.250D02
- JLDQ.19B.435.250D03
- JLDQ.19B.435.250D04
- JLDQ.10.435.250
- JLDQ.3.435.250
- Serie 1.28.000.110.30
Importante: Always verify your existing motor's brand, model, minimum install dimension, stroke, and plug types to ensure compatibility with the replacement unit. Different actuators may not be compatible with all recliner frames.
5. Informazioni sulla sicurezza
Si prega di osservare le seguenti precauzioni di sicurezza:
- Ensure the power supply is disconnected before attempting any installation, maintenance, or troubleshooting.
- Questo motore è progettato esclusivamente per l'uso in ambienti interni.
- Do not operate the motor if any part is damaged or if the cables are frayed.
- Durante il funzionamento, tenere le mani e gli abiti larghi lontani dalle parti in movimento.
- Connection is only to class 2 DC circuit.
- In caso di dubbi su qualche passaggio, consultare un tecnico qualificato.
6. Installazione
The installation process is generally straightforward. Follow these steps:
- Scollegare l'alimentazione: Unplug the recliner or bed from the main power outlet.
- Motore di accesso: Carefully position the recliner to access the existing motor. This may involve tilting the chair or removing a fabric cover.
- Scollegare il vecchio motore:
- Disconnect the 5-pin round plug from the hand control.
- Disconnect the 2-pin square plug from the power supply.
- Unbolt or unclip the old motor from the recliner frame.
- Rimuovere il vecchio motore: Carefully remove the old actuator motor from the recliner mechanism.
- Installare il nuovo motore:
- Position the new Okin JLDQ.10.435.250I motor in the same location as the old one.
- Securely bolt or clip the new motor to the recliner frame.
- Collegare il nuovo motore:
- Collegare la spina rotonda a 5 pin al comando manuale.
- Connect the 2-pin square plug with the clip to the power supply. Ensure a secure connection.
- Funzionalità di prova: Reconnect the recliner to the power outlet and test the motor's operation using the hand control. Ensure smooth extension and retraction.

Immagine 6.1: Lato view of the motor, showing mounting points and overall structure.

Immagine 6.2: Angolata view of the motor, illustrating its compact design for installation.
7. Funzionamento
Once installed and connected, operate the recliner motor using the hand control unit. Press the appropriate buttons on the hand control to extend or retract the recliner mechanism. The motor is designed for intermittent use with an operation frequency of "On 1 min / Off 8 min" to prevent overheating and ensure longevity.

Image 7.1: Visual representation of the motor's features and its application in a recliner chair.
8. Manutenzione
The Okin JLDQ.10.435.250I motor requires minimal maintenance:
- Pulizia: Keep the motor free from dust and debris. Wipe with a dry cloth. Do not use liquid cleaners directly on the motor.
- Ispezione: Periodically inspect the motor and all connections for any signs of wear, damage, or loose fittings.
- Lubrificazione: Il motore è lubrificato in fabbrica e generalmente non necessita di ulteriore lubrificazione.
9. Risoluzione Dei Problemi
If your recliner motor is not functioning correctly, consider the following:
- Nessun potere:
- Ensure the recliner is securely plugged into a working power outlet.
- Controllare l'alimentatore per eventuali spie luminose o segni di danneggiamento.
- Verify the 2-pin square plug connection to the power supply is firm.
- Il motore non risponde:
- Check the 5-pin round plug connection to the hand control.
- Inspect the hand control for damage or stuck buttons.
- Ensure the motor is not jammed by any obstructions in the recliner mechanism.
- Surriscaldamento del motore:
- Adhere to the "On 1 min / Off 8 min" operation frequency. Excessive continuous use can cause overheating.
- Garantire un'adeguata ventilazione attorno al motore.
- Rumori insoliti:
- Disconnect power and inspect the motor and recliner mechanism for any loose parts or foreign objects.
Se le procedure di risoluzione dei problemi non risolvono il problema, contattare l'assistenza clienti.
10. Garanzia e supporto
For warranty information, technical support, or to inquire about replacement parts, please refer to the official Okin brand store or contact your retailer. Keep your purchase receipt for warranty claims.
Visit the official Okin Store: Negozio Okin su Amazon