TRU Components TC-9539292

Manuale utente della colonna di segnalazione a LED TRU COMPONENTS TC-9539292

Modello: TC-9539292

Introduzione

The TRU COMPONENTS TC-9539292 is a robust and durable LED signal column designed for industrial applications. It provides clear visual and audible indications for various operational states. This manual provides essential information for the safe and effective installation, operation, and maintenance of your signal column.

TRU COMPONENTS TC-9539292 LED Signal Column with red and green light segments and attached power cable.

Image: TRU COMPONENTS TC-9539292 LED Signal Column. This image displays the TRU COMPONENTS TC-9539292 LED Signal Column. The column features two distinct light segments: an upper red segment and a lower green segment. A black power cable with exposed wires at the end is shown coiled next to the column, indicating its electrical connection. The base of the signal column includes a threaded section for mounting.

Informazioni sulla sicurezza

Per evitare lesioni e danni al dispositivo, osservare sempre le seguenti precauzioni di sicurezza:

  • Prima di procedere all'installazione, alla manutenzione o alla risoluzione dei problemi, assicurarsi che l'alimentazione sia scollegata.
  • L'installazione deve essere eseguita solo da personale qualificato, nel rispetto delle normative e dei codici elettrici locali.
  • Non esporre il dispositivo a umidità eccessiva, polvere o temperature estreme al di fuori dell'intervallo operativo specificato.
  • Verificare il volume correttotage (24 Volts) before connecting the device.
  • Non tentare di modificare o riparare il dispositivo autonomamente. Rivolgersi a personale qualificato.

Configurazione e installazione

Follow these steps for proper installation of the signal column:

  1. Montaggio: The signal column features a threaded base (M2x15, Hexagonal head style) for secure mounting. Ensure the mounting surface is stable and capable of supporting the device's weight (119 grams).
  2. Cablaggio: Connect the signal column to a 24 Volt power supply. The cable includes multiple wires; refer to the specific wiring diagram provided with your equipment for correct connections to control the red and green LED segments and the audible alarm. Ensure all connections are secure and insulated.
  3. Considerazioni ambientali: Install the column in an environment that is free from excessive vibration and within the recommended operating temperature range. The material is plastic.

Istruzioni per l'uso

The TRU COMPONENTS signal column offers both visual and audible indications:

  • Indicazione visiva: The red and green LED segments can be configured for either continuous illumination or lampeggiante. The specific control signals for these modes will depend on your system's integration.
  • Indicazione acustica: The integrated sounder can produce either a tono continuo o un discontinuous tone (intermittent sound). Consult your system's control logic for activating these audible alerts.

The signal column is designed to integrate with industrial control systems to provide real-time status updates.

Manutenzione

The TRU COMPONENTS signal column is designed for durability and requires minimal maintenance. However, regular checks can extend its lifespan and ensure reliable operation:

  • Pulizia: Periodically clean the exterior of the column with a soft, damp panno. Non usare detergenti abrasivi o solventi.
  • Ispezione: Regularly inspect the wiring and connections for any signs of wear, damage, or loose connections. Ensure the mounting is secure.
  • Controllo LED: Verify that both red and green LED segments illuminate correctly when activated.
  • Sounder Check: Confirm the sounder functions as expected when activated.

Scollegare sempre l'alimentazione prima di effettuare qualsiasi intervento di manutenzione.

Risoluzione dei problemi

If you encounter issues with your signal column, refer to the following common problems and solutions:

ProblemaPossibile causaSoluzione
Nessuna luce o suonoNessuna alimentazione; Cablaggio errato; Unità difettosaCheck power connection (24V); Verify wiring against diagram; Contact support if power and wiring are correct.
Only one LED segment illuminatesIncorrect wiring for specific segment; Faulty LED segmentCheck wiring for the non-illuminating segment; If wiring is correct, the segment may be faulty.
Sounder not workingIncorrect wiring for sounder; Faulty sounderVerify sounder wiring; If wiring is correct, the sounder may be faulty.
Funzionamento intermittenteCollegamenti allentati; Alimentazione instabileCheck all wiring connections for tightness; Ensure power supply is stable.

For issues not listed above, or if solutions do not resolve the problem, please contact TRU Components customer support.

Specifiche

Numero di modelloTC-9539292
ProduttoreCOMPONENTI VERI
Dimensioni (L x P x A)Dimensioni: 10 x 10 x 15 cm
Peso119 grammi
ColoreRosso, Verde
MaterialePlastica
Voltage24 Volt
Numero di pezzi1
Tipo di testaEsagonale
Sistema di misurazioneMetrico
Dimensione del filo1/4"-20 UNC
CaratteristicheContinuous or flashing illumination, Continuous or discontinuous sounder

Garanzia e supporto

TRU Components provides a Disponibilità di 1 anno per i pezzi di ricambio for the TC-9539292 LED Signal Column from the date of purchase.

For technical support, warranty claims, or further assistance, please contact your point of purchase or visit the official TRU Components website. Ensure you have your model number (TC-9539292) and purchase details ready when contacting support.

Documenti correlati - TC-9539292

Preview Scheda tecnica della luce di segnalazione a LED USB TRU COMPONENTS
Dati tecnici e istruzioni per l'uso della luce di segnalazione a LED USB TRU COMPONENTS (codice articolo 2804760), dotata di 7 colori e funzionalità cicalino.
Preview Manuale utente e specifiche tecniche del trasformatore LED TRU Components
Manuale utente completo e specifiche tecniche per i trasformatori LED TRU Components, inclusi numeri di modello, dati elettrici, condizioni operative e linee guida di sicurezza per applicazioni di illuminazione LED per interni.
Preview Dati tecnici e di sicurezza dell'alimentatore per guida DIN TRU Components
Istruzioni di sicurezza complete, uso previsto, spiegazioni dei simboli e specifiche tecniche per gli alimentatori per guida DIN TRU Components, inclusi numeri di modello e parametri operativi.
Preview COMPONENTI TRU Guida DIN Voedingen Gebruiksaanwijzing en Specifiche
Gedetailleerde gebruiksaanwijzing en technische specifiche voor TRU COMPONENTS DIN-rail voedingen. Bevat istruzioni di installazione, informazioni dettagliate e modelli per diverse uitvoeringen.
Preview Alimentatore per guida DIN TRU COMPONENTS - Manuale utente e specifiche
Istruzioni operative complete e specifiche tecniche per gli alimentatori per guida DIN TRU COMPONENTS, che coprono sicurezza, installazione e dati di prodotto dettagliati. Include numeri di modello, caratteristiche elettriche, dimensioni e linee guida di sicurezza.
Preview Manuale utente e specifiche dell'alimentatore per guida DIN TRU COMPONENTS
Manuale utente completo e specifiche tecniche per gli alimentatori per guida DIN TRU COMPONENTS, inclusi i modelli delle serie DPN, DPS e DPH. ...