1. Introduzione
The Elitech STC-1000HX is a versatile digital temperature controller designed for precise temperature management in various applications. It features a large display, switchable Fahrenheit and Celsius units, and two relay outputs for controlling both heating and cooling devices. This manual provides detailed instructions for installation, setup, operation, and maintenance to ensure optimal performance and longevity of your device.
Caratteristiche principali:
- Wide temperature measurement and control range.
- Fahrenheit (℉) and Celsius (℃) switchable display.
- Two relay outputs for independent control of heating and cooling.
- Large, clear digital display for easy readability.
- Waterproof NTC sensor for reliable temperature detection.
- Sensor failure alarm function.

Immagine 1.1: anteriore view of the Elitech STC-1000HX Digital Temperature Controller, showing the digital display and control buttons.
2. Informazioni importanti sulla sicurezza
Please read and understand all safety instructions before installing or operating the STC-1000HX. Failure to follow these instructions may result in electric shock, fire, or damage to the device.
- Garantire l'alimentazione voltage matches the controller's requirements (220V).
- All wiring should be performed by a qualified electrician or knowledgeable individual.
- Scollegare l'alimentazione prima di effettuare qualsiasi cablaggio o manutenzione.
- Do not operate the controller in environments with excessive moisture or corrosive gases.
- Garantire una messa a terra adeguata per evitare rischi elettrici.
- Tenere il dispositivo lontano dalla portata dei bambini.
3. Prodotto finitoview e componenti
3.1 Product Dimensions and Display
The STC-1000HX features a compact design with a large, easy-to-read LED display. The front panel includes buttons for power, settings, and navigation.

Image 3.1: Elitech STC-1000HX showing key dimensions (71mm width, 66mm depth, 29mm height) and icons for cooling, heating, temperature unit selection, and sensor failure alarm.
3.2 Componenti inclusi
Il pacchetto standard include:
- 1 x Elitech STC-1000HX Digital Temperature Controller
- 1 x NTC Waterproof Temperature Sensor (6.6 feet / IP67 rated)
- 1 x Manuale utente

Image 3.2: The waterproof NTC temperature sensor, rated IP67, with a 6.6-foot cable, designed for accurate and reliable temperature measurement in various environments.
4. Guida all'installazione
4.1 Schema elettrico
Carefully follow the wiring diagram below. Ensure all connections are secure and correctly matched to avoid damage to the controller or connected devices. Disconnect power before wiring.

Image 4.1: Wiring diagram for the STC-1000HX. Terminals 1 & 2 are for Cooling (10A/110VAC), 3 & 4 for Heating (10A/110VAC), 5 & 6 for the Temperature Sensor, and 7 & 8 for Power Supply (110VAC).
Istruzioni di cablaggio:
- Connect the main power supply (110V AC) to terminals 7 (Neutral) and 8 (Live).
- Connect the cooling device to terminals 1 (Neutral) and 2 (Live).
- Connect the heating device to terminals 3 (Neutral) and 4 (Live).
- Connect the NTC temperature sensor to terminals 5 and 6. The sensor is non-polar, so connection order does not matter.
4.2 Montaggio
The STC-1000HX is designed for panel mounting. Ensure the cutout dimensions match the controller's size for a secure fit. Allow adequate ventilation around the unit.
5. Impostazione e configurazione
5.1 Accensione/spegnimento
Premere e tenere premuto il tasto Energia pulsante () for 3 seconds to turn the controller ON or OFF.
5.2 Impostazione dei parametri di temperatura
Per accedere alla modalità di impostazione dei parametri, tenere premuto il tasto Impostato pulsante () for 3 seconds. Use the Up (
) E Giù (
) buttons to navigate through parameters and adjust values. Press the Impostato di nuovo per confermare ed uscire.
Parametri comuni:
- SP (Setpoint): La temperatura desiderata.
- HD (Differenziale di riscaldamento): The temperature difference above the setpoint before heating activates.
- CD (raffreddamento differenziale): The temperature difference below the setpoint before cooling activates.
- PT (ritardo del compressore): Delay time for compressor protection.
- CF (Temperature Unit): Passa da Celsius (℃) a Fahrenheit (℉).
6. Istruzioni per l'uso
6.1 Cooling Mode Operation
When the measured temperature exceeds the setpoint plus the cooling differential, the cooling relay will activate, turning on the connected cooling device. The cooling relay will deactivate when the temperature drops to the setpoint.
6.2 Heating Mode Operation
When the measured temperature falls below the setpoint minus the heating differential, the heating relay will activate, turning on the connected heating device. The heating relay will deactivate when the temperature rises to the setpoint.

Image 6.1: The STC-1000HX supports both cooling and heating functions, each with a 10A relay capacity, indicated by snowflake and sun icons respectively.
6.3 funzioni di allarme
The controller includes a sensor failure alarm. If the sensor circuit is open or short-circuited, the display will show an error code (e.g., 'EE') and an audible alarm may sound. Replace the sensor if this occurs.
7. Menu Parameter Settings
To access and modify the advanced parameters, press and hold the Impostato button for 3 seconds. Use the Up/Down buttons to navigate and adjust values.
| Funzione | Imposta intervallo | Predefinito | Descrizione |
|---|---|---|---|
| SP | -50℃ ~ 120℃ (-58℉ ~ 248℉) | 10 ℃ (50 ℉) | Setpoint della temperatura |
| HD | 0.1℃ ~ 10.0℃ (0.2℉ ~ 18.0℉) | 2.0 ℃ (3.6 ℉) | Differenziale di riscaldamento |
| CD | 0.1℃ ~ 10.0℃ (0.2℉ ~ 18.0℉) | 2.0 ℃ (3.6 ℉) | Differenziale di raffreddamento |
| PT | 0 ~ 10 minuti | 3 minuti | Tempo di ritardo del compressore |
| CF | C / F | C | Unità di temperatura (Celsius/Fahrenheit) |
8. Guida alla risoluzione dei problemi
Per i problemi più comuni e le possibili soluzioni, fare riferimento alla tabella sottostante.
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Il display mostra 'EE' | Sensor error (open circuit or short circuit) | Check sensor wiring. Replace sensor if damaged. |
| Il controller non si accende | Nessuna alimentazione o cablaggio errato | Verify power connections to terminals 7 and 8. Check fuse if applicable. |
| Riscaldamento/raffreddamento non attivati | Incorrect setpoint/differential, compressor delay active, faulty relay, or device | Check SP, HD, CD, and PT settings. Wait for compressor delay. Test connected heating/cooling device. Check wiring to terminals 1-4. |
| Lettura della temperatura imprecisa | Sensor placement, damaged sensor, or calibration issue | Ensure sensor is correctly placed and not exposed to direct heat/cold. Replace sensor if damaged. |
9. Specifiche tecniche
- Modello: STC-1000HX
- Alimentazione elettrica: 110V AC, 50 / 60Hz
- Gamma di misurazione della temperatura: Da -50 ℃ a 120 ℃ (da -58 ℉ a 248 ℉)
- Gamma di controllo della temperatura: Da -50 ℃ a 120 ℃ (da -58 ℉ a 248 ℉)
- Risoluzione: 0.1 ℃ / 0.1 ℉
- Precisione: ±1℃ (±2℉)
- Sensore: Sensore NTC (1 pz)
- Uscita relè: 2 Relays (Cooling 10A/110VAC, Heating 10A/110VAC)
- Consumo energetico: <3Settembre
- Temperatura di esercizio: Da -10 ℃ a 60 ℃ (da 14 ℉ a 140 ℉)
- Temperatura di conservazione: Da -20 ℃ a 75 ℃ (da -4 ℉ a 167 ℉)
- Umidità relativa: Dal 20% all'85% (senza condensa)
- Dimensioni del pannello frontale: 71 mm x 29 mm
- Dimensioni del prodotto (LxLxA): Dimensioni: 7.1 x 6.6 x 2.9 cm
- Peso dell'articolo: 200 grammi
10. Manutenzione
To ensure the longevity and accurate operation of your STC-1000HX controller, follow these maintenance guidelines:
- Pulizia: Gently wipe the controller's display and casing con un panno morbido e asciutto. Non utilizzare detergenti abrasivi o solventi.
- Cura del sensore: Periodically inspect the NTC sensor for any signs of damage or corrosion. Ensure it is clean and free from debris that could affect temperature readings.
- Condizioni ambientali: Operate the controller within the specified temperature and humidity ranges to prevent damage.
11. Garanzia e supporto
11.1 Informazioni sulla garanzia
Elitech products are covered by a limited warranty against defects in materials and workmanship. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Elitech websito.
11.2 Assistenza clienti
If you encounter any issues or have questions regarding your Elitech STC-1000HX temperature controller, please contact Elitech customer support through their official websito o le informazioni di contatto fornite nella confezione del prodotto.