1. Introduzione
This manual provides detailed instructions for the safe and efficient operation of your BTECH RPS-30M 30 Amp Regulated Bench Power Supply. The RPS-30M is designed to convert standard AC household current to a stable 13.8V DC output, suitable for powering various DC devices such as CB, Ham, GMRS, and LMR radios.

Figura 1: Fronte view of the BTECH RPS-30M Power Supply.
2. Informazioni sulla sicurezza
To ensure safe operation and prevent damage to the unit or connected devices, please observe the following safety precautions:
- Ventilazione: Ensure adequate ventilation around the power supply. Do not block ventilation openings.
- Fonte di energia: Connect the unit only to a 110V AC, 60Hz power outlet.
- Caratteristiche di protezione: The RPS-30M includes built-in overheat, short circuit, and amperage surge protection. However, avoid intentionally short-circuiting the output terminals.
- Umidità: Non esporre l'unità a pioggia, umidità o umidità eccessiva.
- Sovraccarico: Do not exceed the maximum cumulative current of 30 Amps.
- Manutenzione: Affidare qualsiasi intervento di manutenzione a personale qualificato. Non tentare di aprire o riparare l'unità da soli.
3. Prodotto finitoview
Familiarize yourself with the components and controls of your BTECH RPS-30M power supply.

Figure 2: Labeled front and rear panels of the BTECH RPS-30M Power Supply.
Componenti del pannello frontale:
- Cigarette Plug Terminal (DC Power Outlet 10A): Fornisce fino a 10 Amps of DC power via a standard cigarette lighter socket.
- DC Output On Indicator: A green LED that illuminates when the power supply is active and providing DC output.
- Interruttore di alimentazione: Toggles the power supply ON or OFF.
Componenti del pannello posteriore:
- Input Power Cable Socket: Connects the power supply to an AC wall outlet using the provided power cable.
- Portafusibili: Contains the replaceable 8A fuse for overcurrent protection.
- Ventola di raffreddamento: Automatically activates to dissipate heat during operation, ensuring optimal performance and longevity.
- Output Terminals (DC Output 13.8V): Red (+) and Black (-) screw-type terminals for direct connection of DC devices requiring up to 30 Amps cumulative current.
4. Specifiche
The following table details the technical specifications of the BTECH RPS-30M power supply:

Figure 3: BTECH RPS-30M Power Supply technical specifications.
| Caratteristica | Specificazione |
|---|---|
| Ingresso volumetage | 110 V CA / 60 Hz |
| Volume di uscitatage | Fixed 13.8V DC ±0.5V |
| Dual Power Output | Cigarette Port / Pole Terminals |
| Volume di uscitatage Regolamento | Meno del 2% |
| Corrente di uscita | 30A (Maximum), 25A (Continuous) |
| Increspatura e rumore | Less than 100mVp-p |
| Fusibile | 110V 8A |
| Dimensioni del prodotto (L x P x A) | 7.5 x 5.7 x 1.85 pollici |
| Peso dell'articolo | 2.25 libbre |
5. Impostazione
Follow these steps to set up your BTECH RPS-30M power supply:
- Posizionamento: Place the power supply on a stable, flat surface. Ensure there is sufficient space around the unit for proper ventilation, especially around the cooling fan on the rear panel.
- Connessione alimentazione CA: Connect the provided AC power cable to the input power cable socket on the rear panel of the power supply. Plug the other end into a standard 110V AC, 60Hz wall outlet.
- Collegamento del dispositivo CC:
- For Screw Terminals: Connect your DC device's positive (+) wire to the red terminal and the negative (-) wire to the black terminal on the rear panel. Ensure connections are secure to prevent arcing or poor contact.
- For Cigarette Plug: Insert your DC device's cigarette lighter plug into the cigarette plug terminal on the front panel. This output supports up to 10 Amps.

Figura 4: Esample setup with the BTECH RPS-30M powering a mobile radio.
6. Istruzioni per l'uso
Operating the BTECH RPS-30M is straightforward:
- Accensione: After connecting your DC devices, flip the Power Switch on the front panel to the 'ON' position. The DC Output On indicator LED will illuminate, indicating that the unit is providing power.
- Spegni: To turn off the power supply, flip the Power Switch to the 'OFF' position. The DC Output On indicator LED will turn off.
- Dispositivi multipli: The RPS-30M can power multiple devices simultaneously, provided their combined current draw does not exceed the maximum cumulative current of 30 Amps. Remember that the front cigarette plug output is limited to 10 Amps.

Figure 5: The RPS-30M powering an RF amplifier and a handheld radio.
7. Manutenzione
Regular maintenance helps ensure the longevity and reliable performance of your power supply:
- Pulizia: Periodically wipe the exterior of the unit with a soft, dry cloth. Do not use liquid cleaners or solvents.
- Ventilazione: Ensure the cooling fan and ventilation openings on the rear panel remain clear of dust and obstructions. Use compressed air to gently clear any accumulated dust if necessary.
- Sostituzione fusibile: If the unit fails to power on, check the fuse located in the fuse holder on the rear panel. To replace, disconnect the AC power cable, unscrew the fuse holder cap, remove the old fuse, and insert a new 8A, 250V fuse. Replace the cap securely.
8. Risoluzione Dei Problemi
If you encounter issues with your BTECH RPS-30M, refer to the following troubleshooting guide:
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Power supply does not turn on (no LED indicator) | No AC power; Blown fuse; Faulty power switch | Check AC power cable connection and wall outlet. Replace fuse (see Maintenance section). If issue persists, contact support. |
| Connected device does not power on | Incorrect DC connection; Device fault; Overload protection activated | Verify positive and negative connections. Test device with another power source. Reduce total current draw if multiple devices are connected. |
| L'unità si surriscalda e si spegne | Ventilazione bloccata; Carico eccessivo | Ensure cooling fan and vents are clear. Reduce the load on the power supply. Allow unit to cool down before restarting. |
9. Garanzia e supporto
BTECH products are designed in the USA and come with local warranty and support. For warranty claims, technical assistance, or further inquiries, please refer to the contact information provided with your purchase or visit the official BTECH websito. Conservare la prova d'acquisto per la convalida della garanzia.