Tenmars TM-901N

Manuale utente del tester per cavi LAN Tenmars TM-901N

Model: TM-901N

1. Introduzione

The Tenmars TM-901N is a professional LAN cable tester designed for efficient and accurate diagnosis of network cable issues. It is capable of identifying various wiring faults such as discontinuity, short-circuits, incorrect connections, and split pairs in both Shielded Twisted Pair (STP) and Unshielded Twisted Pair (UTP) cables. This device can measure cable lengths up to 265 meters, making it an essential tool for network installers and technicians.

2. Informazioni sulla sicurezza

Si prega di leggere attentamente tutte le istruzioni di sicurezza prima di utilizzare il dispositivo. Il mancato rispetto di queste istruzioni può causare lesioni o danni al dispositivo.

  • Do not attempt to test live circuits or cables connected to active network equipment.
  • Ensure the battery is correctly installed before use.
  • Non esporre il dispositivo a umidità o temperature estreme.
  • Non aprire il dispositivo casing, poiché ciò potrebbe invalidare la garanzia ed esporvi a rischi elettrici.
  • Smaltire le batterie secondo le normative locali.

3. Contenuto della confezione

Verifica che tutti gli articoli siano presenti nel tuo pacco:

  • Tenmars TM-901N Main Unit
  • Remote ID Locator (ID 1)
  • Manuale dell'utente (questo documento)
  • Note: A 9V battery is typically required and may not be included.
Tenmars TM-901N LAN Cable Tester main unit and remote ID locator

Image 3.1: Tenmars TM-901N Main Unit and Remote ID Locator.

4. Prodotto finitoview

4.1 Unità principale

Davanti view of Tenmars TM-901N LAN Cable Tester main unit with LCD display and control buttons

Immagine 4.1: anteriore view of the TM-901N Main Unit.

The main unit features an LCD display for showing test results and cable status. It includes several control buttons:

  • Pulsante PROVA: Initiates a cable test.
  • L/W Button: Toggles between Length measurement and Wiremap display modes.
  • SET/UNIT Button: Used to enter settings mode and change measurement units (e.g., meters, feet).
  • Pulsanti freccia (sinistra/destra): Used for navigation in settings or for reviewi risultati dei test.

4.2 Remote ID Locator

Remote ID locator unit for Tenmars TM-901N LAN Cable Tester

Image 4.2: Remote ID Locator.

The remote ID locator is a passive unit used in conjunction with the main unit to test installed cables. It connects to one end of the cable while the main unit connects to the other. The remote unit is labeled "ID 1" for identification.

4.3 Rear Panel and Wiring Diagram

Posteriore view of Tenmars TM-901N main unit showing battery compartment and wiring diagram

Immagine 4.3: posteriore view of the TM-901N Main Unit with wiring diagram.

The rear panel of the main unit includes the battery compartment and a printed wiring diagram for reference, showing standard T568A/B pin assignments for RJ45 connectors.

5. Impostazione

5.1 Installazione della batteria

  1. Locate the battery compartment cover on the rear of the main unit.
  2. Slide the cover open or remove it as indicated.
  3. Inserire una nuova batteria da 9 V, assicurandosi della corretta polarità (+/-).
  4. Riposizionare saldamente il coperchio del vano batteria.
Open battery compartment of Tenmars TM-901N LAN Cable Tester

Image 5.1: Battery compartment with cover removed.

5.2 Collegamento dei cavi per i test

Before connecting any cables, ensure they are disconnected from all active network devices.

  • For patch cables (uninstalled cables): Connect one end of the cable to the RJ45 port on the main unit and the other end to the RJ45 port on the remote ID locator.
  • For installed cables: Connect the main unit to one end of the installed cable (e.g., a wall jack) and the remote ID locator to the other end of the cable (e.g., in a patch panel).

6. Istruzioni per l'uso

6.1 Accensione/Spegnimento

The device typically powers on automatically when a cable is connected and the TEST button is pressed, or by pressing the TEST button. It usually powers off automatically after a period of inactivity to conserve battery.

6.2 Esecuzione di un test del cavo

  1. Ensure the cable is properly connected to the main unit and the remote ID locator.
  2. Premere il tasto TEST pulsante.
  3. The tester will automatically scan the cable and display the results on the LCD.

6.3 Interpreting Test Results (Wiremap)

The LCD will display the wiremap, indicating the connection status of each wire pair. Common indications include:

  • Passaggio: All wires are correctly connected (1-1, 2-2, etc. for straight-through, or appropriate cross-over mapping).
  • Open/Discontinuity: A break in one or more wires. The display will show which wire(s) are open.
  • Cortocircuito: Two or more wires are touching. The display will indicate the shorted wires.
  • Incorrect Connection/Miswire: Wires are connected to the wrong pins at one or both ends. The display will show the incorrect mapping (e.g., 1-3, 2-6).
  • Coppie divise: A more complex fault where two pairs are swapped, but the wiremap appears correct. The tester is designed to detect this.

6.4 Measuring Cable Length

  1. After performing a test, press the L / W button to switch to Length measurement mode.
  2. The display will show the estimated length of the cable.
  3. To change the unit of measurement (meters, feet), press the SET/UNIT button while in Length mode and use the arrow buttons to select the desired unit. Press SET/UNIT di nuovo per confermare.

7. Manutenzione

7.1 Pulizia

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no moisture enters the device.

7.2 Sostituzione della batteria

When the battery low indicator appears on the display, replace the 9V battery as described in Section 5.1. Remove the battery if the device will not be used for an extended period to prevent leakage.

7.3 Conservazione

Conservare il dispositivo in un luogo fresco e asciutto, lontano dalla luce solare diretta e da temperature estreme. Conservarlo nella confezione originale o in una custodia protettiva quando non in uso.

8. Risoluzione Dei Problemi

ProblemaPossibile causaSoluzione
Il dispositivo non si accende.Batteria scarica o scarica; batteria installata in modo errato.Sostituire la batteria da 9 V; controllare la polarità della batteria.
Misurazione della lunghezza imprecisa.Cable not fully extended; incorrect cable type setting (if applicable); cable damage.Ensure cable is straight; verify cable integrity; check if unit calibration is needed (refer to advanced settings if available).
"Open" or "Short" displayed for a new cable.Faulty cable; improper connection to tester.Re-seat the cable connectors firmly; try testing a known good cable; inspect cable for visible damage.
No display or erratic display.Batteria scarica; guasto interno.Sostituire la batteria. Se il problema persiste, contattare l'assistenza clienti.

9. Specifiche

CaratteristicaSpecificazione
ModelloTM-901N
Type of TesterLAN wiring
Measured Cable LengthMax. 265m
Risoluzione di misurazione1m
Cable/Adapter StructurePresa RJ45
Caratteristiche di misurazioneConnection map test: discontinuity, short circuit, incorrect connection, split pairs
Cavi supportatiSTP / UTP cables
Precisione della misurazione±10% ±1m
Alimentazione elettricaBatteria da 9 Vx1
Peso160g
DimensioniDimensioni: 130x58x35mm
ProduttoreTENMAR
Paese di origineTaiwan

10. Garanzia e supporto

For warranty information and technical support, please refer to the documentation provided with your purchase or contact your local distributor. Keep your proof of purchase for warranty claims.