Introduzione

Thank you for choosing the KAIWEETS VT500 Non-Contact Voltage Tester. This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your device. Please read this manual thoroughly before use and retain it for future reference.

KAIWEETS VT500 Vol senza contattotageTester

The KAIWEETS VT500 Non-Contact Voltage Tester, a versatile tool for electrical measurements.

Informazioni sulla sicurezza

Always adhere to basic safety precautions when using electrical testing equipment to reduce the risk of fire, electric shock, and personal injury. This device is designed for professional and DIY use, but proper handling is crucial.

KAIWEETS VT500 tester showing correct usage without gloves for accurate readings.

Per un volume accuratotage readings and to avoid electric shock risks, always use the tester without gloves when performing contact measurements. The image shows the tester correctly detecting voltage when held by a bare hand, and incorrectly when held with a glove, emphasizing the importance of direct contact for certain functions.

Contenuto della confezione

Verificare che tutti gli articoli siano presenti e integri al momento dell'apertura del pacco:

KAIWEETS VT500 Voltage Tester and its packaging.

The KAIWEETS VT500 Voltage Tester as it appears in its retail packaging.

Prodotto finitoview

The KAIWEETS VT500 is a versatile electrical testing tool designed for safety and convenience. Key features include:

KAIWEETS VT500 clipped to a pocket using its portable pen hook.

The KAIWEETS VT500 features a portable pen hook for easy carrying and accessibility.

KAIWEETS VT500 probe tip functioning as a screwdriver.

The robust probe tip of the KAIWEETS VT500 can also be used as a screwdriver, adding to its utility.

Impostare

Installazione della batteria

  1. Individuare il coperchio del vano batteria sul retro del dispositivo.
  2. Per aprire, far scorrere o sganciare il coperchio.
  3. Inserire una batteria AAA, assicurandosi che la polarità sia corretta (+/-) come indicato all'interno del vano.
  4. Chiudere saldamente il coperchio del vano batterie.

Istruzioni per l'uso

1. Accensione/spegnimento

KAIWEETS VT500 demonstrating its 15-minute auto-off feature.

The KAIWEETS VT500 automatically powers off after 15 minutes of inactivity to conserve battery life.

2. Vol. senza contattotage (NCV) Rilevamento

3. Rilevamento filo in tensione

KAIWEETS VT500 displaying 'HI' for live wire detection.

The KAIWEETS VT500 indicating a live wire with 'HI' on its display and an audible alarm.

4. Volumetage Misurazione (Contatto)

KAIWEETS VT500 displaying '228V' during contact voltage misurazione.

The KAIWEETS VT500 showing a contact voltage measurement of 228V on its LCD screen.

KAIWEETS VT500 demonstrating live wire detection and contact voltage misurazione.

The KAIWEETS VT500 performing two functions: Live Wire detection (buzzer alarms, LED shows HI) and Contact Voltage Test (accurate readings, safety warning, buzzer alarms quickly).

5. Test di continuità

KAIWEETS VT500 displaying continuity.

The KAIWEETS VT500 indicating continuity with a specific symbol on its display and an audible buzzer.

KAIWEETS VT500 detecting a breakpoint in a cable.

The KAIWEETS VT500 identifying a breakpoint within an electrical cable, indicated by a change in detection.

6. Battery Polarity Test

KAIWEETS VT500 performing battery polarity detection.

The KAIWEETS VT500 testing battery polarity. Touch the test probe to the positive terminal and hold the negative terminal with your other hand. If polarity is correct, the screen displays '---P' and a buzzer sounds.

7. Funzione torcia

KAIWEETS VT500 flashlight illuminating a dark electrical panel.

The integrated flashlight of the KAIWEETS VT500 provides convenient illumination when working in dark environments.

Manutenzione

Sostituzione della batteria

When the low battery indicator appears on the display, replace the AAA battery as described in the 'Battery Installation' section. Always use a fresh, high-quality AAA battery.

Pulizia e conservazione

Risoluzione dei problemi

ProblemaPossibile causaSoluzione
Il dispositivo non si accende.Batteria scarica o installata in modo errato.Replace battery with a new AAA battery, ensuring correct polarity.
Vol. imprecisotage letture.Poor contact; testing with gloves; low battery.Ensure firm contact with the conductor. Remove gloves for contact tests. Replace battery.
NCV detection is inconsistent.Weak signal; interference; distance from source.Move closer to the voltage source. Ensure no strong electromagnetic interference.
Buzzer does not sound.Batteria scarica; malfunzionamento del dispositivo.Sostituire la batteria. Se il problema persiste, contattare l'assistenza.

Specifiche

CaratteristicaSpecificazione
Numero di modelloVT500
MarcaKAIWEET - dolciumi
Volume ACtage Range (Contatto)12V - 300V
Conformità alla sicurezzaCAT.II 300V, CE, RoHS
Fonte di alimentazione1 batteria AAA (inclusa)
Dimensioni (confezione)Dimensioni: 16 x 3.7 x 2.4 cm
Peso (confezione)70 grammi
ColoreNero
CaratteristicheNCV, Voltmeter, Continuity, Battery Polarity, Flashlight, Screwdriver Tip

Garanzia e supporto

KAIWEETS products are designed and manufactured to high-quality standards. For warranty information, technical support, or service inquiries, please refer to the contact details provided on the KAIWEETS official website or your purchase documentation. Please have your model number (VT500) and purchase date available when contacting support.

Documenti correlati - VT500

Preview KAIWEETS VT200 Vol senza contattotagManuale operativo del tester
Manuale operativo ufficiale per il vol senza contatto KAIWEETS VT200tage tester, che fornisce istruzioni dettagliate sull'uso, sulle caratteristiche di sicurezza, sul prodottoview, specifiche tecniche e manutenzione.
Preview Manuale utente del multimetro digitale KAIWEETS KM100
Guida completa al multimetro digitale KAIWEETS KM100, che copre le operazioni di sicurezza, lo schema del misuratore, le funzioni, le procedure di misurazione per la tensione CC/CAtage, corrente continua, resistenza, continuità e test dei diodi, insieme a specifiche tecniche e manutenzione.
Preview Manuale utente del multimetro digitale KAIWEETS HT118A
Manuale utente completo per il multimetro digitale KAIWEETS HT118A, che comprende istruzioni di sicurezza, descrizione del prodotto, caratteristiche del multimetro, funzioni di misurazione e specifiche.
Preview Istruzioni e guida alla sicurezza del tester di presa Kaiweets KM117B
Guida completa per il tester di prese Kaiweets KM117B, che descrive in dettaglio le sue caratteristiche per il rilevamento di problemi di cablaggio, test GFCI e voltage misurazioni. Include avvertenze di sicurezza e specifiche tecniche.
Preview Manuale utente del multimetro digitale KAIWEETS HT113B
Manuale utente completo per il multimetro digitale KAIWEETS HT113B, che descrive in dettaglio le sue caratteristiche, specifiche e istruzioni operative per test elettrici accurati.
Preview VT200 Vol senza contattotagManuale d'uso del rilevatore e
Manuale utente per il Kaiweets VT200 senza contatto voltage rilevatore, che copre le precauzioni di sicurezza, prodotto finitoview, funzionamento, sostituzione della batteria e specifiche generali.