1. Introduzione
The AUTENS AD-100L Dehumidifying Dry Cabinet is designed to provide a stable, low-humidity environment for the long-term storage and preservation of sensitive items. Utilizing advanced microprocessor and TE Cooling technology, this cabinet effectively protects valuable equipment such as DSLR/SLR cameras, lenses, electronic components, and other moisture-sensitive materials from humidity, dust, rust, oxidation, and degradation. Its energy-saving, noiseless operation ensures a safe and convenient storage solution.

Figura 1: Fronte view of the AUTENS 100L Dehumidifying Dry Cabinet, showcasing its capacity to store various camera equipment.
2. Informazioni sulla sicurezza
- Assicurarsi che il mobile sia posizionato su una superficie stabile e piana per evitare che si ribalti.
- Do not expose the cabinet to direct sunlight, high temperatures, or heat sources, as this can affect performance and internal temperature.
- Keep the cabinet away from water or excessive moisture to prevent electrical hazards.
- Do not block the ventilation openings on the cabinet.
- This dry cabinet operates with a noiseless and heatless system, ensuring no radiation or significant heat emission, making it safe for placement in various indoor environments.
- The cabinet is equipped with a lock and keys to secure contents and prevent unauthorized access.
3. Prodotto finitoview
3.1 Componenti
- Cabinet Body: Constructed from high-quality steel plate with an aluminum alloy frame.
- Porta: Durable toughened glass with a magnetic seal and locking mechanism.
- Pannello di controllo: Digital display showing real-time temperature and humidity, with control buttons for settings.
- Scaffali: Adjustable crystal shelves (clear plastic) for flexible storage configurations.
- Wave Sponge: Foam inserts designed to cradle lenses and other delicate items.
- Luci LED: Internal LED lighting for visibility, with ON/OFF control.
- Piedini regolabili: For leveling the cabinet on uneven surfaces.
- Chiavi: For locking the cabinet door.

Figure 2: Key components of the AUTENS Dehumidifying Dry Cabinet.
4. Impostazione
4.1 Disimballaggio
Carefully remove the dry cabinet from its packaging. Inspect the cabinet for any signs of damage during transit. Retain packaging materials for future transport or storage if needed.
4.2 Posizionamento
Place the dry cabinet in a location that is stable, dry, and away from direct sunlight, high temperatures, or any heat-emitting appliances. Ensure adequate air circulation around the unit.

Figure 3: Product dimensions for placement consideration. Height: 770mm (approx. 30.3 inches), Width: 380mm (approx. 15 inches), Depth: 390mm (approx. 15.35 inches).
4.3 Livellamento
The AD-100L model is equipped with adjustable feet. Rotate the feet at the bottom of the cabinet to ensure it is perfectly level, especially if the floor surface is uneven. This helps maintain proper door sealing and optimal operation.
4.4 Installazione dello scaffale
Insert the crystal shelves into the desired slots within the cabinet. The shelves are adjustable to accommodate items of various sizes. Place the wave sponge inserts on the shelves as needed to protect delicate items like lenses.

Figure 4: Interior of the dry cabinet with adjustable shelves and wave sponge inserts.
4.5 Operazione iniziale
Before storing any items, it is recommended to run the dry cabinet empty for more than 8 hours. This allows the internal humidity to stabilize and reach a lower level, preparing the cabinet for optimal performance.
5. Istruzioni per l'uso
5.1 Accensione e visualizzazione
Plug the power adapter into a suitable electrical outlet and connect it to the dry cabinet. The digital LED dual screen will illuminate, displaying the current internal temperature and relative humidity (RH%).

Figure 5: Digital control panel displaying temperature and humidity.
5.2 Impostazione dei livelli di umidità
Use the control buttons on the panel to set your desired relative humidity (RH%) level. The cabinet allows control within the range of 25% to 60% RH.
- Premere il pulsante "SET" per accedere alla modalità di impostazione.
- Use the "Up" or "Down" arrow buttons to adjust the target humidity.
- Press "SET" again to confirm your selection.
5.3 Controllo della luce a LED
The internal LED lights can be turned ON or OFF using the dedicated button on the control panel. Turning off the lights can help save energy, especially at night.
5.4 Suggerimenti operativi importanti
- It may take at least 3 hours for the cabinet to reach the set humidity point when storing a large quantity of items or items with high moisture content for the first time.
- The internal temperature of the dry cabinet is monitored but cannot be actively controlled by the unit.
- Always ensure the cabinet door is sealed tightly after opening to maintain optimal dehumidification. The magnetic door seal provides a secure closure.
- It is normal for the internal humidity level to increase after the door is opened, as ambient air enters. The longer the door remains open, the higher the humidity increase will be. The cabinet will resume dehumidifying to the set level once the door is closed.
6. Recommended Humidity Levels for Storage
The ideal humidity level for storage varies depending on the type of item. Refer to the table below for recommended relative humidity (RH%) levels:

Figure 6: Guide for optimal humidity settings based on item type.
| Relative Humidity (RH%) Level | Articoli consigliati |
|---|---|
| 50% - 60% | Books, antique documents, paper, copy, print |
| 40% - 50% | Videocamere, macchine fotografiche, obiettivi, telescopi, microscopi, endoscopi, compact disc, pellicole negative, diapositive/lucidi per pellicole, microfilm, unità disco, nastri audio e video |
| 30% - 40% | Mental and metal powder products, electrical equipment, semiconductors, capacitors, printed circuit boards, IC, batteries, other electronic equipment, precision measuring tools, spectrometers, optics, lenses |
| 25% - 30% | Materie prime farmaceutiche, spezie, verniciatura a polvere, adesivi, semi, polline, farina secca |
7. Manutenzione
7.1 Pulizia
To clean the exterior of the cabinet, wipe with a soft, damp cloth. For the interior, ensure the cabinet is unplugged and use a dry, soft cloth to wipe down surfaces. Avoid using abrasive cleaners or solvents that could damage the finish or internal components.
7.2 Ispezione della guarnizione della porta
Periodically inspect the magnetic door seal for any signs of wear or damage. A proper seal is crucial for maintaining the desired humidity level inside the cabinet. If the seal is compromised, contact customer support.
8. Risoluzione Dei Problemi
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Humidity not dropping to set level. |
|
|
| Il display non funziona. |
|
|
| Rumore insolito. |
|
|
If you encounter issues not listed here or if troubleshooting steps do not resolve the problem, please contact AUTENS customer support for assistance.
9. Specifiche
| Caratteristica | Specificazione |
|---|---|
| Nome del modello | AD-100L |
| Capacità | 100 litri |
| Dimensioni del prodotto (A x L x P) | 770 mm x 380 mm x 390 mm (circa 30.3 x 15 x 15.35 pollici) |
| Consumo energetico | 8 Watt |
| Gamma di controllo dell'umidità | 25% - 60% UR |
| Precisione dell'umidità | ±1% RH (Laboratory Data) |
| Display | Digital LED Dual Screen (Temperature & Humidity) |
| Scaffali | Adjustable Crystal Shelves (5 layers for 100L model) |
| Tipo di blocco | Blocco chiave |
| Materiale | Steel Plate, Aluminum Alloy Frame, Toughened Glass Door |
10. Garanzia e supporto
AUTENS provides a warranty for this product against defects in materials and workmanship under normal use. For specific warranty terms, duration, and to obtain technical support or service, please refer to the warranty card included with your product or visit the official AUTENS website. You may also contact AUTENS customer service directly for assistance with any product-related inquiries or issues.
Produttore: AUTENTIC




