ANCEL S200

ANCEL S200 Automotive Smoke Machine

Manuale d'uso

Introduzione

The ANCEL S200 Automotive Smoke Machine is a diagnostic tool designed for detecting leaks in various automotive systems. It features a built-in air pump and advanced overheat protection, making it suitable for EVAP, vacuum, exhaust, and other system leak tests in cars, motorcycles, and trucks. This manual provides detailed instructions for the proper setup, operation, maintenance, and troubleshooting of the device.

Caratteristiche principali

Comparison of ANCEL S200 with traditional smoke machines, highlighting built-in air pump, fast smoke output, non-hazard smoke, and self-protection system.

Figure 1: ANCEL S200 advantages over traditional leak detectors.

Contenuto della confezione

The ANCEL S200 package includes the following items:

Image showing the ANCEL S200 main unit and all included accessories: power cord, delivery hose, funnel, intake bladder, service replacement, adapter cone set, EVAP adapter, and EVAP removal tool.

Figure 2: Complete package contents of the ANCEL S200.

Guida all'installazione

Follow these steps to prepare your ANCEL S200 for leak detection:

  1. Aggiungere l'olio di prova: Open the oil filler port on the top of the unit. Use the provided funnel to carefully pour approximately 20ml of test oil (e.g., baby oil) into the unit. Observe the oil level gauge to ensure it does not exceed the maximum fill line. Overfilling can lead to oil spills.
  2. Installa Hook: Screw the hanging hook into the designated port on the top of the unit. This allows you to hang the device securely during testing.
  3. Collegare il cavo di alimentazione: Insert the power cord into the power socket on the unit. Connect the red clamp al terminale positivo (+) della batteria da 12 V del veicolo e al polo neroamp al terminale negativo (-).
  4. Install Smoke Hose: Connect the delivery hose to the air/smoke output port on the unit.
Four-step visual guide for setting up the ANCEL S200: Pouring oil, connecting the detector with pipe fitting, connecting power supply, and smoke generation.

Figure 3: Quick setup steps for the ANCEL S200.

Video 1: ANCEL S200 Setup and Operation Overview.

Istruzioni per l'uso

The ANCEL S200 offers two primary operating modes for effective leak detection:

1. Modalità aria

In Air Mode, the unit generates air pressure without smoke. This mode is useful for a quick preliminary check to determine if a leak exists before introducing smoke. It helps in identifying larger leaks or confirming system integrity.

2. Modalità fumo

In Smoke Mode, the unit generates thick, visible smoke to accurately pinpoint the exact location of leaks. This is the primary mode for detailed leak detection.

Leak Detection Process:

  1. Seleziona modalità: Use the mode selector switch on the unit to choose between Air Mode (fan icon) or Smoke Mode (smoke icon).
  2. Connetti al sistema: Attach the appropriate adapter cone or intake bladder to the system you wish to test (e.g., intake manifold, exhaust pipe, EVAP port). Ensure a tight seal.
  3. Attiva unità: Turn on the unit. In Smoke Mode, smoke will generate quickly, typically within 10 seconds.
  4. Osservare il manometro: Monitor the built-in pressure gauge. A significant drop in pressure indicates a leak.
  5. Individuare la perdita: In Smoke Mode, observe for smoke escaping from any part of the system. The smoke will clearly indicate the leak's location.
Image showing the dual working modes of the ANCEL S200: Air Mode for checking if there is a leak, and Smoke Mode for accurately pinpointing the leak location.

Figure 4: Dual operating modes for leak detection.

Visual display of the pressure gauge indicating no leak, minor leak, and massive leak based on pressure value changes.

Figure 5: Interpreting the pressure gauge for leak status.

Video 2: Demonstrating adapter usage for different system openings.

Leak Detection Applications

The ANCEL S200 is capable of detecting leaks in a wide range of automotive systems:

Diagram illustrating various automotive systems where the ANCEL S200 can detect leaks, including EVAP, fuel tank, intake, engine, exhaust, and crankcase systems.

Figure 6: Comprehensive system leak detection capabilities.

Image demonstrating exhaust system leak detection with smoke exiting the exhaust pipe.

Figure 7: Exhaust system leak detection.

Image showing EVAP system leak detection under the hood of a car.

Figure 8: EVAP system leak detection.

Image illustrating cabin air leak detection by running smoke around car seams.

Figure 9: Cabin air leak detection.

Manutenzione

To ensure optimal performance and longevity of your ANCEL S200, regular maintenance is recommended:

Risoluzione dei problemi

Per i problemi più comuni e le relative soluzioni, fare riferimento alla tabella sottostante:

IndiceErrorePossibile motivoSoluzione
#1LED not OnMistaken Positive to Navigate / Poor Contact of Power LineConnect to power source correctly / Check with meter if the power line is broken, confirm and replace it
#2Pump is on, but no air outputFlow Dial Not Open / Pump FailureOpen the flow dial anti-clockwise / Replace a new pump
#3No Smoke OutputSmoke Oil Out or Overfilled / Voltage Low / Heater DamagedCheck oil level; turn unit upside down while the oil filler port is open, and refill to the correct level / Check battery voltage if it's over 12V / If current consumption less than 5Amp, sostituire il riscaldatore
#4Weak Smoke, Obvious Oil Drops from the OutputSmoke Oil Not Compatible / Voltage BassoChange proper smoke oil / Check battery voltage se è superiore a 12V
#5Slow Oil Drops from the OutputNormal Smoke CondensationPeriodically take off the smoke hose and blow it with an air gun
#6Sudden Stop of Smoke OutputProtezione surriscaldamento attivataCool down the unit before use again
Troubleshooting table for ANCEL S200, listing common errors, possible reasons, and solutions.

Figure 10: Troubleshooting guide.

Specifiche

CaratteristicaSpecificazione
ModelloS200
Attuale12V Fully Charged vehicle battery
Portata6A
Fonte di alimentazione< 6 L/min
Uscita pressione0.5-1.0 bar / 0.8-14.5 psi
Peso unità principale2.06 kg
Peso del pacco2.2 kg
Dimensioni del prodottoDimensioni: 25 x 24 x 17 cm
Paese di origineCina
Detailed specifications of the ANCEL S200, including current, flow rate, power source, pressure output, weight, and dimensions.

Figure 11: ANCEL S200 technical specifications.

Informazioni sulla sicurezza

The ANCEL S200 is designed with user safety in mind:

Image highlighting safety features of the ANCEL S200, including no need to start the car, non-hazard smoke, anti-frost protection, and overheat protection.

Figure 12: ANCEL S200 safety features.

Garanzia e supporto

The ANCEL S200 comes with a 3-year warranty. For technical support or any inquiries, please contact ANCEL customer service. Contact information can typically be found in the included user manual or on the official ANCEL websito.

Documenti correlati - S200

Preview Manuale utente del rilevatore di perdite di fumo diagnostico per autoveicoli ANCEL
Manuale utente completo per il rilevatore di perdite di fumo diagnostico per autoveicoli Ancel, che copre funzionamento, specifiche, risoluzione dei problemi e informazioni sulla garanzia. Scopri come testare efficacemente vari sistemi di tubazioni dei veicoli per individuare eventuali perdite.
Preview Manuale utente del rilevatore di perdite di fumo diagnostico per autoveicoli - Ancel S200/S300
Manuale utente completo per il rilevatore di perdite di fumo diagnostico Ancel Automotive (modelli S200 e S300). Scopri le sue caratteristiche, specifiche, componenti, funzionamento, risoluzione dei problemi e garanzia per un'efficace rilevazione delle perdite nei veicoli.
Preview Manuale d'uso del rilevatore di perdite di fumo diagnostico per autoveicoli ANCEL
Manuale utente completo per il rilevatore di perdite di fumo diagnostico per autoveicoli ANCEL, che ne descrive le caratteristiche, il funzionamento, gli accessori, le specifiche, la risoluzione dei problemi e le conoscenze sul sistema EVAP.
Preview Manuale utente del rilevatore di perdite di fumo diagnostico per autoveicoli ANCEL
Manuale utente per il rilevatore di perdite di fumo diagnostico per autoveicoli ANCEL, che fornisce informazioni dettagliate sulle sue caratteristiche, funzionamento, accessori, specifiche, risoluzione dei problemi e test del sistema EVAP per la diagnostica automobilistica.
Preview Manuale utente del rilevatore di perdite diagnostico per autoveicoli ANCEL
Manuale d'uso per il rilevatore di perdite diagnostico per autoveicoli ANCEL, che descrive in dettaglio le specifiche, l'elenco dei componenti, il funzionamento e la garanzia.
Preview Manuale utente dello strumento di scansione OBD II ANCEL AD310
Manuale utente completo per lo strumento di scansione OBD II ANCEL AD310, che descrive in dettaglio le sue caratteristiche, il funzionamento, le precauzioni di sicurezza, le funzioni diagnostiche e le informazioni sulla garanzia.