1. Introduzione
This manual provides comprehensive instructions for the installation, operation, and maintenance of the Axis Communications D8208-R Industrial 8-Port Managed PoE++ Switch. This device is designed for robust industrial environments, offering reliable network connectivity and Power over Ethernet (PoE++) capabilities for connected devices. Please read this manual thoroughly before using the product to ensure proper and safe operation.
2. Informazioni sulla sicurezza
Per evitare danni al prodotto e garantire la sicurezza dell'utente, osservare le seguenti precauzioni di sicurezza:
- Fonte di energia: Use only the specified power supply for this device. Ensure the power source meets the voltage e le attuali esigenze.
- Ambiente: Install the switch in an environment that complies with its operating temperature and humidity specifications. Avoid exposure to direct sunlight, excessive heat, moisture, or corrosive substances.
- Ventilazione: Assicurare un'adeguata ventilazione attorno al dispositivo per evitare il surriscaldamento. Non ostruire le aperture di ventilazione.
- Installazione: L'installazione deve essere eseguita da personale qualificato, nel rispetto delle normative e dei codici elettrici locali.
- Manutenzione: Do not attempt to open or service the device yourself. Refer all servicing to qualified service personnel.
- cavi: Use appropriate and certified cables for all connections.
3. Contenuto della confezione
Verify that all items are present in the package. If any item is missing or damaged, contact your supplier.
- AXIS D8208-R Industrial 8-Port Managed PoE++ Switch
- Guida di installazione rapida
- Mounting Kit (e.g., DIN rail clip, screws)
- Terminal Block Connectors (for power input)
4. Prodotto finitoview
The AXIS D8208-R is a robust industrial switch designed for demanding applications. It features multiple Ethernet ports with Power over Ethernet capabilities and advanced management features.
4.1 Disposizione del pannello frontale

Figura 1: Davanti view of the AXIS D8208-R Industrial Switch. This image displays the front panel of the switch, highlighting the various Ethernet ports, power input terminals, LED indicators, and the console port. Ports 1-4 are 1G PoE++ ports, ports 5-8 include 1G and 2.5G PoE++ capabilities, and ports 9-10 are 10G SFP+ ports.

Figura 2: Fronte dettagliato view of the AXIS D8208-R Industrial Switch. This image provides a closer look at the port configuration and LED indicators. It shows the two 10G SFP+ uplink ports (9 and 10) at the bottom, the console port, and the reset button. The power input terminals are visible on the right side.
4.2 Components Description
- Porte Ethernet (1-4): 1 Gigabit Ethernet ports with PoE++ (802.3bt) support.
- Porte Ethernet (5-8): 1 Gigabit and 2.5 Gigabit Ethernet ports with PoE++ (802.3bt) support.
- 10G Ports (9-10): 10 Gigabit SFP+ uplink ports for high-speed connections.
- Power Input (P1, P2): Redundant power input terminals for enhanced reliability.
- Porta della console: RJ45 port for local management and configuration via a serial connection.
- Pulsante di reset: Utilizzato per ripristinare le impostazioni di fabbrica del dispositivo o per riavviarlo.
- Indicatori LED:
- SYS: Indicatore di stato del sistema.
- P1, P2: Power input status indicators.
- ALMA: Indicatore di allarme.
- RM, RC: Redundancy Management / Redundancy Control indicators.
5. Impostazione
5.1 Montaggio
The AXIS D8208-R is designed for DIN rail mounting.
- Attach the DIN rail clip (if not pre-installed) to the rear of the switch using the provided screws.
- Hook the top edge of the DIN rail clip onto the DIN rail.
- Spingere con decisione la parte inferiore dell'interruttore verso la guida DIN finché non scatta in posizione.
- Assicurarsi che l'interruttore sia fissato saldamente alla guida DIN.
5.2 Collegamento di alimentazione
The switch supports redundant power inputs (P1 and P2) for increased reliability.
- Ensure the power source is turned off before making any connections.
- Connect the positive (+) and negative (-) wires from your DC power supply to the corresponding terminals on the provided terminal block connector for P1.
- Insert the terminal block connector into the P1 power input port on the switch.
- (Optional) For redundant power, repeat steps 2 and 3 for the P2 power input.
- Once all connections are secure, turn on the power supply. The P1 and/or P2 LEDs should illuminate.
5.3 Connessione di rete
Connect network devices and uplink connections.
- Standard Devices: Connect your network devices (e.g., IP cameras, access points) to ports 1-8 using standard Ethernet cables. These ports will provide PoE++ power if the connected device supports it.
- Collegamento in salita: For high-speed uplink to your core network, insert compatible SFP+ transceivers into ports 9 and 10, then connect fiber optic cables.
5.4 Configurazione iniziale
L'interruttore può essere configurato tramite un web-based interface or a command-line interface (CLI) through the console port.
- Web Interfaccia: Connect a computer to any Ethernet port on the switch. The switch will typically obtain an IP address via DHCP or use a default static IP. Refer to the Quick Installation Guide for the default IP address and login credentials.
- Porta della console: Connect a serial cable from your computer to the console port on the switch. Use a terminal emulation program (e.g., PuTTY) with the specified serial settings (e.g., 115200 baud, 8 data bits, no parity, 1 stop bit, no flow control) to access the CLI.
6. Operativo
6.1 Indicatori LED
Monitor the LED indicators for the operational status of the switch.
| GUIDATO | Stato | Descrizione |
|---|---|---|
| SISTEMA | Verde (Fisso) | Il sistema funziona normalmente. |
| SISTEMA | Verde (lampeggiante) | System is booting or performing an operation. |
| P1 / P2 | Verde (Fisso) | Corresponding power input is active. |
| ALM | Red (Solid/Flashing) | An alarm condition exists (e.g., power failure, port error). Check system logs. |
| LED delle porte | Verde (Fisso) | Collegamento stabilito. |
| LED delle porte | Verde (lampeggiante) | Attività sui dati. |
6.2 Gestione e configurazione
The AXIS D8208-R is a managed switch, offering a range of configuration options for network optimization and security.
- WebGUI basata su: Accedi allo switch web interfaccia tramite uno standard web browser to configure VLANs, QoS, port settings, PoE management, security features, and more.
- CLI: For advanced users, the Command Line Interface provides granular control over all switch functions.
- SNMP: The switch supports SNMP for integration with network management systems.
7. Manutenzione
7.1 Pulizia
To maintain optimal performance, periodically clean the exterior of the switch.
- Assicurarsi che l'alimentazione sia scollegata prima della pulizia.
- Utilizzare un panno morbido e asciutto per pulire le superfici esterne.
- Non utilizzare detergenti liquidi o spray, poiché potrebbero danneggiare il dispositivo.
- Mantenere le aperture di ventilazione libere da polvere e detriti.
7.2 Aggiornamenti firmware
Regularly check the Axis Communications website for the latest firmware updates. Firmware updates can provide new features, performance improvements, and security enhancements.
- Scarica il firmware appropriato file from the official Axis Communications support page for your model.
- Follow the instructions provided with the firmware update package for the correct update procedure, typically performed via the web interfaccia.
8. Risoluzione Dei Problemi
If you encounter issues with your AXIS D8208-R switch, refer to the following common troubleshooting steps.
- Nessun potere:
- Check power cable connections to the switch and the power source.
- Verificare che l'alimentatore funzioni correttamente e fornisca la tensione correttatage.
- Ensure the P1/P2 LEDs are illuminated.
- Nessuna connettività di rete:
- Check Ethernet cable connections for both the switch and the connected device.
- Verify the link/activity LEDs on the respective port are active.
- Assicurarsi che il dispositivo connesso sia acceso e configurato correttamente.
- Check switch configuration (VLANs, port status) via the web interfaccia o CLI.
- Dispositivo PoE non acceso:
- Ensure the connected device is PoE compatible and within the switch's PoE budget.
- Check the PoE status for the port in the switch's management interface.
- Verify the Ethernet cable is a standard Cat5e/6 or higher.
- Accesso Web Interface Fails:
- Confirm your computer's IP address is in the same subnet as the switch, or that DHCP is functioning.
- Try accessing the switch via the console port to verify its IP configuration.
- Svuota la cache del browser o prova un altro browser.
- Ripristino di fabbrica: If issues persist and you need to restore default settings, press and hold the reset button for approximately 10-15 seconds until the SYS LED changes behavior, then release. Attenzione: questa operazione cancellerà tutte le configurazioni personalizzate.
9. Specifiche
| Caratteristica | Dettaglio |
|---|---|
| Marca | Comunicazioni dell'asse |
| Numero di modello | 02621-001 |
| Nome del prodotto | AXIS D8208-R Industrial 8-Port Managed PoE++ Switch |
| Porti | 8 x PoE++ Ethernet (1G/2.5G), 2 x 10G SFP+ |
| Potenza in ingresso | Redundant DC power input (terminal blocks) |
| Peso dell'articolo | 3.37 libbre (circa 1.53 kg) |
| Dimensioni del pacco | 1.97 x 0.79 x 0.79 pollici (circa 5 x 2 x 2 cm) |
| Produttore | AXIS - ACCESS CONTROL |
| Data prima disponibilità | 29 maggio 2024 |
10. Garanzia e supporto
For detailed warranty information, technical support, and additional resources, please visit the official Axis Communications websito.
Websito: www.axis.com
Contact Axis Communications support for assistance with product installation, configuration, or troubleshooting beyond the scope of this manual.