1. Introduzione

This manual provides comprehensive instructions for the safe and effective operation of the KAIWEETS KC602 Smart Clamp Misuratore. Leggere attentamente il presente manuale prima dell'uso e conservarlo per riferimento futuro.

Informazioni sulla sicurezza

Always adhere to local and national safety codes. Use appropriate personal protective equipment (PPE) when working with electrical circuits. Do not exceed the maximum input values specified for the meter. Disconnect power to the circuit before making connections or disconnections.

2. Prodotto finitoview e componenti

The KAIWEETS KC602 is an intelligent clamp meter designed for precise measurement of AC/DC current, AC/DC voltage, frequency, duty cycle, resistance, capacitance, diode, continuity, and temperature. It features a smart measurement mode, True-RMS, and a high-definition color screen.

KAIWEETS KC602 Smart Clamp Misuratore con accessori

Figure 2.1: KAIWEETS KC602 Smart Clamp Meter and included accessories, including test leads, K-type thermocouple, and carrying case.

KAIWEETS KC602 Clamp Meter in use, showing automatic shutdown, CAT.IV 600V rating, and automatic range selection

Figure 2.2: Key features of the KC602, including automatic shutdown, CAT.IV 600V safety rating, and automatic range selection for ease of use.

Contenuto della confezione:

3. Impostazione

3.1 Installazione della batteria

  1. Individuare il coperchio del vano batterie sul retro del misuratore.
  2. Utilizzare un cacciavite per aprire il vano batteria.
  3. Inserire 2 batterie AAA, assicurandosi della corretta polarità (+ e -).
  4. Riposizionare il coperchio del vano batteria e fissarlo con la vite.

3.2 Accensione iniziale e calibrazione

Upon first power-on or after battery replacement, the KC602 performs an automatic calibration. This process ensures measurement accuracy.

KAIWEETS KC602 showing automatic calibration and smart mode detection

Figure 3.1: The meter displays "CAL" during automatic calibration upon power-on, followed by entering Smart Mode.

The meter will automatically enter Smart Mode, which intelligently recognizes measurement signals.

4. Istruzioni per l'uso

4.1 Smart Measurement Mode

In Smart Mode, the KC602 automatically identifies and measures AC/DC Voltage, Resistance, and Continuity. Simply connect the test leads to the circuit, and the meter will display the relevant measurement.

KAIWEETS KC602 in Smart Mode with HD color screen

Figure 4.1: The KC602 operating in Smart Mode, automatically detecting measurement signals and displaying results on its HD color screen.

4.2 Funzioni di misura specifiche

To access specific measurement functions beyond Smart Mode, press the FUNC pulsante per scorrere le modalità disponibili.

KAIWEETS KC602 showing various measurement functions including AC/DC current, voltage, resistance, frequency, NCV, inrush, diode, and temperature

Figure 4.2: The KC602 offers a wide range of functions to meet diverse measurement needs.

Misurazione della corrente AC/DC

To measure AC/DC current, select the current mode. Open the clamp jaws and enclose a single conductor. The display will show the current reading.

KAIWEETS KC602 measuring AC/DC Voltage and AC/DC Current

Figure 4.3: Top image shows AC/DC Voltage measurement using test leads. Bottom image shows AC/DC Current measurement using the clamp jaws around a single conductor.

Volume AC/DCtage Misurazione

Connect the red test lead to the VΩHz input jack and the black test lead to the COM input jack. Select the voltage mode and connect the test leads in parallel to the circuit or component to be measured.

Misurazione della corrente di spunto

The inrush current function measures the initial surge of current when a device is powered on. This is useful for diagnosing motor or circuit startup issues. The measurement time is approximately 100ms.

KAIWEETS KC602 performing an inrush current test

Figure 4.4: The KC602 measuring inrush current, with a measurement range of 5 to 600 A.

Volume senza contattotage (NCV) Test

The NCV function allows for voltage detection without direct contact. Hold the NCV sensor near the conductor. The meter will indicate the presence of AC voltage con un segnale acustico e un indicatore visivo.

KAIWEETS KC602 performing non-contact voltage test for low and high voltage

Figure 4.5: The KC602's NCV function indicating low voltage (left) and high voltage (right) without physical contact.

Continuity, Diode, and Capacitance Tests

These functions are essential for checking circuit integrity, diode functionality, and capacitor values.

KAIWEETS KC602 performing continuity, diode, and capacitance tests

Figure 4.6: Demonstrations of Continuity Test (left), Diode Test (center), and Capacitance Test (right) using the KC602.

Misurazione della temperatura

Use the included K-type thermocouple to measure temperature. Insert the thermocouple into the appropriate input jacks and place the probe on the surface or in the environment to be measured.

KAIWEETS KC602 measuring AC/DC Current, AC/DC Voltage, NCV, and Temperature

Figura 4.7: Esamples of various measurements: AC/DC Current (top left), AC/DC Voltage (top right), NCV (bottom left), and Temperature (bottom right).

5. Manutenzione

5.1 Pulizia

Per pulire il misuratore, pulire la custodia con un pannoamp cloth and mild detergent. Do not use abrasives or solvents. Ensure the meter is powered off and disconnected from any circuits before cleaning.

5.2 Sostituzione della batteria

When the battery power indicator appears on the display, replace the batteries promptly to ensure accurate measurements. Refer to Section 3.1 for battery installation instructions.

5.3 Conservazione

Se il misuratore non viene utilizzato per un periodo prolungato, rimuovere le batterie per evitare perdite. Conservare il misuratore in un luogo fresco e asciutto, lontano dalla luce solare diretta e da temperature estreme.

5.4 Spegnimento automatico

The KC602 features an automatic shutdown function to conserve battery life. If no operation is performed within 15 minutes, the meter will automatically power off.

KAIWEETS KC602 showing automatic shutdown timer and HD color screen display

Figure 5.1: The meter's automatic shutdown feature activates after 15 minutes of inactivity, indicated by a countdown.

6. Risoluzione Dei Problemi

ProblemaPossibile causaSoluzione
Il misuratore non si accende.Batterie scariche o installate in modo errato.Sostituire le batterie assicurandosi che la polarità sia corretta.
Letture imprecise.Batteria scarica, funzione selezionata in modo errato o interferenza ambientale.Replace batteries, select correct function, move away from strong electromagnetic fields.
No display or partial display.Problema con la batteria o guasto interno.Controllare/sostituire le batterie. Se il problema persiste, contattare l'assistenza clienti.

7. Specifiche

ParametroValore
ModelloIl KC602
Gamma di corrente CA/CC0-600A
Visualizza i conteggi6000 Conteggi
Vero RMS
Gamma automatica
Misurazione della corrente di spuntoYes (5-600A, approx. 100ms)
Volume senza contattotage (PCV)
Fonte di alimentazione2 batterie AAA
Peso dell'articolo240 grammi
DimensioniDimensioni: 22.6 x 11.8 x 5.2 cm
Valutazione di sicurezzaCAT.IV 600V, CE Certified

8. Garanzia e supporto

KAIWEETS provides 3 years of customer service and lifetime technical support for the KC602 Smart Clamp Meter. If you have any concerns or require assistance, please contact KAIWEETS customer support.

For support, please visit the official KAIWEETS websito o contattare direttamente il venditore tramite la piattaforma in cui è stato acquistato il prodotto.

Documenti correlati - Il KC602

Preview Manuale utente del multimetro digitale KAIWEETS HT118A
Manuale utente completo per il multimetro digitale KAIWEETS HT118A, che comprende istruzioni di sicurezza, descrizione del prodotto, caratteristiche del multimetro, funzioni di misurazione e specifiche.
Preview KAIWEETS HT206D Digitale Clamp Manuale utente e specifiche del misuratore
Manuale utente completo per il cl digitale KAIWEETS HT206Damp misuratore. Include istruzioni dettagliate sul funzionamento, precauzioni di sicurezza, caratteristiche, specifiche e manutenzione per questo contatore AC/DC a gamma automatica T-RMS.amp metro.
Preview KAIWEETS HT206D True-RMS Digital Clamp Manuale utente del misuratore
Manuale utente completo per il KAIWEETS HT206D True-RMS Digital Clamp Misuratore. Scopri le sue caratteristiche, le informazioni sulla sicurezza, le istruzioni per l'uso e le specifiche per misurazioni elettriche accurate.
Preview Manuale utente del multimetro digitale intelligente Kaiweets KM601
Manuale utente completo per il multimetro digitale intelligente Kaiweets KM601, che comprende informazioni sulla sicurezza, caratteristiche del prodotto, modalità di misurazione (SMART e MANUALE), descrizioni dei terminali, manutenzione, specifiche e garanzia.
Preview KAIWEETS KC602 True-RMS Smart Clamp Manuale utente del misuratore
Manuale utente per KAIWEETS KC602 True-RMS Smart Clamp Misuratore. Questa guida descrive in dettaglio le caratteristiche, la sicurezza, il funzionamento e le funzioni di misurazione per corrente CA/CC, voltage, resistenza e altro ancora, garantendo un utilizzo ottimale del dispositivo.
Preview KAIWEETS KC602 True-RMS Smart Clamp Manuale utente del misuratore
Manuale utente per KAIWEETS KC602 True-RMS Smart Clamp Misuratore, che ne descrive le caratteristiche, il funzionamento sicuro e le capacità di misurazione elettrica, inclusa la cattura della corrente di spunto.