phrozen CUREMEGAS00US

Phrozen Cure Mega S User Manual

Model: CUREMEGAS00US

Introduzione

The Phrozen Cure Mega S is an advanced resin curing station designed for post-processing 3D printed models. It features both drying and UV curing functions, a 360-degree transparent turntable, and dual high-speed fans to ensure efficient and uniform curing of large and small models. This manual provides essential information for the safe and effective operation, setup, and maintenance of your Phrozen Cure Mega S.

Informazioni sulla sicurezza

Per evitare lesioni o danni, leggere attentamente tutte le istruzioni di sicurezza prima di utilizzare il dispositivo.

Prodotto finitoview

The Phrozen Cure Mega S is a robust curing station designed for large-scale and high-volume post-processing. Its intuitive design allows for easy access and efficient operation.

Phrozen Cure Mega S 3D Printer Resin Curing Station

Immagine: Frontale view of the Phrozen Cure Mega S curing station, showcasing its compact, black enclosure with a transparent orange-tinted door.

Componenti chiave

Phrozen Cure Mega S Smart Design Features

Image: Visual representation of the Phrozen Cure Mega S's smart design, highlighting the side-swing door, interior lighting, and the touch panel interface.

Impostare

Follow these steps for the initial setup of your Phrozen Cure Mega S.

  1. Disimballare il dispositivo: Carefully remove the Phrozen Cure Mega S from its packaging. Retain all packaging materials for future transport or storage.
  2. Scegli una posizione: Place the curing station on a flat, stable, and heat-resistant surface in a well-ventilated area. Ensure there is sufficient space around the unit for air circulation.
  3. Connetti alimentazione: Plug the power cord into the power input port on the back of the unit, then plug the other end into a grounded electrical outlet.
  4. Install Turntable: Place the transparent turntable securely onto the rotating mechanism inside the curing chamber.
  5. Optional Rack Installation: If curing smaller or multiple models, install the removable rack at the desired height within the chamber.
  6. Accensione: Press the power button on the touch panel to turn on the device.

Operazione

The Phrozen Cure Mega S offers versatile drying and curing options for your 3D printed models.

Drying and Curing Functions

The device allows you to select between drying, curing, or a combined dry and cure cycle.

Phrozen Cure Mega S Dual-Action Drying and Curing

Image: Depicts the Phrozen Cure Mega S in operation, highlighting its dual-action drying (1700 RPM) and 360-degree curing capabilities.

Utilizzo del pannello a sfioramento

The touch panel provides intuitive control over the device's functions.

  1. Seleziona modalità: On the main screen, tap the desired mode: Fan + Cure (Dry & Cure), UV Cure, O Fan (Drying).
  2. Imposta ora: Use the '+' and '-' buttons to adjust the duration for the selected mode. Recommended curing times vary based on resin type and model size.
  3. Inizio ciclo: Press the 'Start' button to begin the process. The interior light will activate, and the turntable will begin to rotate.
  4. Monitorare i progressi: Use the built-in interior light to observe the drying or curing state of your models through the transparent door.
  5. Fine ciclo: The device will automatically stop once the set time has elapsed. You can also manually stop the cycle by pressing the 'Stop' button.
Phrozen Cure Mega S Detachable Rack and Curing Capacity

Image: Illustrates the detachable rack feature, showing how it accommodates both large single models and multiple smaller models for flexible curing.

Manutenzione

Regular maintenance ensures optimal performance and longevity of your Phrozen Cure Mega S.

Risoluzione dei problemi

This section addresses common issues you might encounter with your Phrozen Cure Mega S.

ProblemaPossibile causaSoluzione
Il dispositivo non si accende.Cavo di alimentazione non collegato correttamente; nessuna corrente dalla presa.Controllare il collegamento del cavo di alimentazione. Testare la presa con un altro dispositivo.
La luce UV non si attiva.Curing mode not selected; door not fully closed.Ensure 'UV Cure' or 'Fan + Cure' mode is selected. Close the door securely.
Il giradischi non gira.Turntable not properly seated; obstruction.Re-seat the turntable. Check for any debris obstructing rotation.
Models not curing evenly.Insufficient curing time; models too close together.Increase curing time. Ensure models are spaced adequately on the turntable.
Models not drying effectively.Drying mode not selected; fans obstructed.Ensure 'Fan' or 'Fan + Cure' mode is selected. Check for obstructions near fan vents.

Specifiche

Technical specifications for the Phrozen Cure Mega S.

CaratteristicaDettaglio
Numero di modelloCUREMEGAS00US
Dimensioni del prodotto15.6"D x 18.7"W x 19.1"H (39.5cm W x 47.5cm D x 48.6cm H)
Peso dell'articolo15 chilogrammi (33.07 libbre)
MaterialeMetallo
Lunghezza d'onda di polimerizzazione405nm UV Light
Velocità della ventola1700 RPM (Dual Fans)
Turntable Rotation360 gradi
ProduttorePHROZEN TECH CO., LTD.
Prima data disponibile9 agosto 2023
Phrozen Cure Mega S Dimensions

Image: Diagram showing the physical dimensions of the Phrozen Cure Mega S: 47.5cm depth, 39.5cm width, and 48.6cm height.

Garanzia e supporto

For warranty information, technical support, or service inquiries, please contact Phrozen customer support through their official websito o rivenditore presso cui è stato acquistato il prodotto.

Risorse online: Visit the official Phrozen website for FAQs, updated drivers, and additional support materials.

Informazioni sui contatti: Refer to your purchase documentation or the Phrozen websito per dettagli di contatto specifici.

Documenti correlati - CUREMEGAS00US

Preview Manuale utente Phrozen CURE+: configurazione, funzionamento e specifiche
Questo manuale utente fornisce istruzioni complete per la stazione di polimerizzazione della resina Phrozen CURE+, che riguardano l'installazione, l'ambiente operativo, le precauzioni di sicurezza, i dettagli del prodotto, gli accessori, le specifiche tecniche, le modalità di polimerizzazione, i profile gestione, impostazioni e assistenza post-vendita.
Preview Phrozen Cure UV Curing Lamp Guida per l'utente
Manuale d'uso per Phrozen Cure UV Curing Lamp, che descrive in dettaglio l'alimentazione, il funzionamento, l'impostazione dei tempi di polimerizzazione e le procedure di manutenzione.
Preview Manuale utente Phrozen CURE+: Guida alla post-polimerizzazione delle stampe 3D
Manuale utente completo per il dispositivo di post-polimerizzazione Phrozen CURE+. Scopri di più su configurazione, modalità operative, specifiche, sicurezza e manutenzione per una polimerizzazione ottimale della stampa 3D.
Preview Manuale utente Phrozen CURE+: configurazione, funzionamento e specifiche
Manuale utente completo per l'unità di polimerizzazione Phrozen CURE+. Informazioni su configurazione, procedure operative, precauzioni di sicurezza, specifiche del prodotto e risoluzione dei problemi.
Preview Phrozen LUNA CURE UV Curing Lamp Guida per l'utente
Manuale utente completo per Phrozen LUNA CURE UV Curing Lamp, che copre il funzionamento elettrico, le impostazioni del tempo di polimerizzazione, gli avvisi di sicurezza e le procedure di manutenzione.
Preview Manuale utente Phrozen CURE+: configurazione, funzionamento e impostazioni
Manuale utente per l'unità di polimerizzazione Phrozen CURE+. Fornisce istruzioni su configurazione, requisiti ambientali, componenti della macchina, accessori, specifiche del prodotto, istruzioni per l'uso, impostazioni di polimerizzazione (resina di marca, elenco personalizzato, manuale) e impostazioni di sistema. Scopri come utilizzare e manutenere la tua Phrozen CURE+ per una polimerizzazione ottimale della stampa 3D.