Introduzione
This manual provides detailed instructions for the safe and effective use of the KAIWEETS KM201 Smart Digital Multimeter. The KM201 is a compact, auto-ranging multimeter designed for measuring voltage, resistance, and continuity, featuring True RMS for accurate readings and Non-Contact Voltage (NCV) detection for enhanced safety. Please read this manual thoroughly before operation and retain it for future reference.
Informazioni sulla sicurezza
Always adhere to local and national safety codes. Use appropriate personal protective equipment (PPE) when working with electrical circuits. Do not use the device if it appears damaged or if the test leads are compromised. Ensure the battery compartment is securely closed before operation.
Contenuto della confezione
Verificare che tutti gli articoli siano presenti nel pacco:
- 1 x KAIWEETS KM201 Smart Digital Multimeter
- 2 batterie AAA
- 1 x Manuale utente (questo documento)
Prodotto finitoview
The KAIWEETS KM201 is designed for ease of use and portability. Below is an illustration of the device and its main components.

Figura 1: Davanti e dietro view of the KAIWEETS KM201 Multimeter, showing the display, function buttons, and integrated test leads with storage clips.
Caratteristiche principali:
- Modalità automatica intelligente: Identifica automaticamente il tipo di misurazione (voltage, resistenza, continuità).
- Vero valore efficace: Fornisce letture accurate per forme d'onda non sinusoidali.
- Volume senza contattotage (NCV) Rilevamento: Rileva AC voltage senza contatto fisico.
- Test della sequenza di fase: Identifies live and phase wires.
- Retroilluminazione e torcia: Migliora la visibilità in condizioni di scarsa illuminazione.
- Data Hold: Blocca la lettura corrente sul display.
- Spegnimento automatico: Conserva la durata della batteria.
- Indicatore di batteria scarica: Avvisa quando è necessario sostituire la batteria.
Impostare
Installazione della batteria
- Individuare il coperchio del vano batteria sul retro del multimetro.
- Utilizzare un cacciavite per aprire il vano batteria.
- Inserire due batterie AAA, assicurandosi della corretta polarità (+/-).
- Riposizionare il coperchio del vano batteria e fissarlo con la vite.
Note: The device will display a low battery indicator when batteries need replacement.
Istruzioni per l'uso
Accensione/spegnimento
Premere il tasto Pulsante di accensione (
) to turn the multimeter on or off. The device will automatically power off after a period of inactivity to conserve battery.
Smart Automatic Mode
The KM201 features a smart automatic mode that simplifies measurements. When powered on, the multimeter defaults to this mode, indicated by "Auto" on the display. In this mode, the device automatically detects and measures AC/DC voltage, resistenza e continuità.

Figura 2: The multimeter display indicating "Auto" mode, ready for automatic measurement.
Voltage Test (AC/DC)
In Smart Automatic Mode, connect the test leads to the circuit or component you wish to measure. The multimeter will automatically detect and display the AC or DC voltage.
- Ensure the test leads are securely plugged into the COM and INPUT jacks.
- Touch the red probe to the positive terminal or live wire and the black probe to the negative terminal or neutral/ground wire.
- Leggi il vol.tage valore sul display.

Figura 3: Misurazione del voltage on a car battery using the KM201 multimeter.
Test di resistenza e continuità
In Smart Automatic Mode, the multimeter will automatically switch to resistance or continuity measurement when connected to a non-powered circuit.
- Prima di collegare i puntali di prova, assicurarsi che il circuito sia disattivato.
- Collegare i puntali di prova lungo il percorso del componente o del circuito.
- For continuity, if the resistance is less than approximately 50 ohms, the screen will turn green and a beeping sound will indicate continuity.
- For resistance, the display will show the resistance value in ohms (Ω), kilohms (kΩ), or megohms (MΩ).

Figura 4: Performing a resistance and continuity test on electrical components within a fuse box.
Volume senza contattotage (NCV) Rilevamento
La funzione NCV consente il rilevamento sicuro della tensione CAtage senza contatto diretto con i conduttori.
- Premere il tasto Pulsante NCV (labeled V=K))) NCV) to activate NCV mode.
- Move the top tip of the multimeter close to the wire or outlet.
- Se AC voltage is detected, the screen will display red, show "-H", and emit a rapid beeping sound, indicating the presence of live voltage.

Figura 5: Using the NCV function to detect live voltage in an electrical outlet, indicated by a red screen and audible alarm.
Test di fase
The phase test helps identify live and phase wires.
- Premere il tasto Pulsante di fase (labeled Phase ← Live) to activate the phase test mode.
- Mettere a contatto la sonda rossa con il filo che si desidera testare.
- The display will indicate "Phase" or "Live" to identify the wire type.

Figura 6: Performing a phase test on electrical wiring to identify live conductors.
Retroilluminazione e torcia
The KM201 includes a backlight for the display and a built-in flashlight for improved visibility in dark environments.
- Premere il tasto Pulsante retroilluminazione/torcia elettrica (
) per attivare/disattivare la retroilluminazione del display. - Premere e tenere premuto il tasto Pulsante retroilluminazione/torcia elettrica per accendere o spegnere la torcia.

Figura 7: The KM201 multimeter with its display backlight and integrated flashlight active, illuminating wires in a dark space.
Manutenzione
Pulizia
Pulisci il multimetro casing con annuncioamp panno e detergente delicato. Non utilizzare detergenti abrasivi o solventi. Assicurarsi che il dispositivo sia asciutto prima di riporlo o utilizzarlo.
Sostituzione della batteria
When the low battery indicator appears on the display, replace the batteries as described in the "Battery Installation" section. Always use two new AAA batteries of the same type.
Magazzinaggio
Se il multimetro non viene utilizzato per un periodo prolungato, rimuovere le batterie per evitare perdite. Conservare il dispositivo in un luogo fresco e asciutto, lontano dalla luce solare diretta e da temperature estreme.
Risoluzione dei problemi
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Il multimetro non si accende. | Batterie scariche o installate in modo errato. | Controllare la polarità delle batterie o sostituirle. |
| Letture imprecise. | Damaged test leads; incorrect measurement technique; external interference. | Inspect test leads for damage; ensure proper connection; move away from strong electromagnetic fields. |
| "Auto" mode not selecting desired measurement (e.g., continuity instead of voltagE). | The smart auto mode prioritizes voltage detection. If a small voltage is present, it may default to voltage misurazione. | Ensure the circuit is completely de-energized for resistance/continuity tests. The KM201 is primarily designed for automatic detection, which may not suit all specific manual mode requirements. |
| Il display è scuro o tremolante. | Batteria scarica. | Sostituire le batterie. |
Specifiche
| Caratteristica | Dettaglio |
|---|---|
| Numero di modello | Prezzo KM201 |
| Marca | KAIWEET - dolciumi |
| Visualizza i conteggi | 2000 Conteggi |
| Tipo di misurazione | Smart Digital Multimeter (True RMS) |
| Fonte di alimentazione | 2 batterie AAA (incluse) |
| Dimensioni (L x P x A) | 13.97 x 4.57 x 3.56 cm (5.5 x 1.8 x 1.4 pollici) |
| Peso | 200 grammi (circa 7.05 once) |
| Valutazione di sicurezza | 600V CAT II, 300V CAT III, CE compliant |
| Caratteristiche | Smart Auto Mode, NCV, Phase Test, Backlight, Flashlight, Data Hold, Auto Power Off, Low Battery Indicator |
Garanzia e supporto
KAIWEETS fornisce un Garanzia di servizio di 36 mesi E supporto tecnico a vita for the KM201 Smart Digital Multimeter. For any inquiries, technical assistance, or warranty claims, please contact KAIWEETS customer service through their official channels.