1. Introduzione
The KAIWEETS Digital Multimeter KM100S is a versatile and reliable tool designed for various electrical testing needs. It provides accurate readings for AC and DC voltage, direct current, resistance, continuity, and diode, making it suitable for household, automotive, and industrial electrical issues.
Cosa c'è nella scatola:
- KAIWEETS Digital Multimeter KM100S
- Cavi di prova (rosso e nero)
- Manuale d'uso
- 2 batterie AAA (incluse)

2. Informazioni sulla sicurezza
Always adhere to safety precautions when using electrical testing equipment. This multimeter meets CAT III 600V safety standards and is equipped with double fuses (F400mA/250V and F10A/250V) for overload protection across all ranges.
- Non tentare di misurare il voltagcorrenti o correnti che superano i limiti massimi specificati.
- Prima di ogni utilizzo, assicurarsi che i puntali di prova siano correttamente collegati e in buone condizioni.
- Always select the correct measurement function and range before connecting the multimeter to a circuit.
- Prestare la massima attenzione quando si lavora su circuiti elettrici sotto tensione.
- Non utilizzare il multimetro se appare danneggiato o non funziona correttamente.

3. Prodotto finitoview
Familiarize yourself with the components of your KAIWEETS Digital Multimeter KM100S.

Caratteristiche principali:
- Display: Large, backlit LCD for clear readings, even in low-light conditions.
- Funzione Quadrante: Interruttore rotante per selezionare la modalità di misurazione desiderata.
- Jack di ingresso: Dedicated ports for test leads based on measurement type (VΩmA, COM, 10A).
- kickstand: Foldable stand for hands-free operation and improved readability.
- Data Hold: Button to freeze the displayed reading.
- Indicatore di batteria scarica: Icon on display to alert when batteries need replacement.
4. Impostazione
4.1 Installazione della batteria
The KM100S requires 2 AAA batteries (included). To install or replace batteries:
- Assicurarsi che il multimetro sia spento.
- Individuare il vano batterie sul retro dell'unità.
- Utilizzare un piccolo cacciavite per aprire il coperchio della batteria.
- Inserire le 2 batterie AAA, rispettando la polarità corretta (+/-).
- Riposizionare il coperchio della batteria e fissarlo con la vite.

4.2 Collegamento del puntale di prova
Connect the test leads to the appropriate input jacks based on the desired measurement:
- Collegare sempre il puntale di prova nero al COM Jack (comune).
- Per volumetage, resistance, continuity, diode, and capacitance measurements, connect the red test lead to the VΩmA cricco.
- For direct current measurements up to 10A, connect the red test lead to the 10A cricco.
Video 1: Official KAIWEETS KM100S Digital Multimeter overview, demonstrating setup and basic functions.
5. Modalità operative
Turn the function dial to select the desired measurement mode.
5.1 CA/CC voltage Misurazione
Use this mode to measure alternating current (AC) or direct current (DC) voltage. Connect the red lead to VΩmA and the black lead to COM.


5.2 Misurazione della corrente continua
Measure direct current (DC) flowing through a circuit. Note: This multimeter cannot be used to measure AC current. Connect the red lead to the 10A jack (for up to 10A) or VΩmA (for milliamps/microamps) and the black lead to COM.

5.3 Resistance, Continuity, Diode, and Capacitance
The KM100S offers various modes for comprehensive electrical testing:
- Resistenza (Ω): Measures the opposition to current flow in a circuit.
- continuità (
): Checks for a complete circuit path with an audible beep. - Diodo (
): Verifica la funzionalità dei diodi. - Capacità: Measures the ability of a component to store an electrical charge.
5.4 Senza contatto voltage (PCV)
La funzione NCV consente di rilevare la tensione CAtage without direct contact, providing an audible alert and visible display when voltage is present. This is useful for quickly identifying live wires.

6. Manutenzione
6.1 Pulizia
Pulisci il multimetro casing con annuncioamp panno. Non usare detergenti abrasivi o solventi.
6.2 Sostituzione del fusibile
The multimeter is protected by double fuses (F400mA/250V and F10A/250V). If the multimeter fails to function correctly, especially in current measurement modes, the fuses may need replacement. Refer to the battery installation section for instructions on opening the casing to access the fuses.
7. Risoluzione Dei Problemi
- Nessun display/Display debole: Controllare l'installazione delle batterie e sostituirle se sono scariche.
- Letture errate: Ensure the correct function is selected, test leads are properly connected, and leads are not damaged.
- Nessun segnale acustico di continuità: Verify the continuity mode is selected and the circuit is complete. Check fuses if current measurement is also affected.
8. Specifiche
| Caratteristica | Valore |
|---|---|
| Dimensioni del prodotto | 6.1 x 3.82 x 1.65 pollici |
| Peso dell'articolo | 9.6 once |
| Numero modello articolo | KM100 |
| Batterie | Sono necessarie 2 batterie AAA (incluse) |
| Produttore | KAIWEET - dolciumi |
| Paese di origine | Cina |
| Fonte di alimentazione | Alimentato a batteria |
| Colore | Nero |
9. Garanzia e supporto
KAIWEETS provides a 36-month high-quality service and lifetime technical support for the KM100S Digital Multimeter. If you have any questions or require assistance while using the tool, please do not hesitate to contact KAIWEETS customer support.
For more information or support, visit the official KAIWEETS websito o fare riferimento ai recapiti forniti sulla confezione del prodotto.