The ALLmeter Non-Contact 2-in-1 Multimeter Tester Pen is a versatile electrical testing instrument designed for measuring AC/DC voltage, resistance, continuity, and diodes. It features a non-contact voltage (NCV) function for enhanced safety and an automatic range selection for ease of use. This compact device is suitable for various applications, including home electrical work, automotive diagnostics, and educational purposes.

ALLmeter Multimeter Tester Pen with various measurement icons

Image 1.1: The ALLmeter Multimeter Tester Pen highlighting its diverse measurement capabilities including NCV, voltage, resistance, continuity, diode, and frequency.

2. Informazioni sulla sicurezza

Always adhere to safety precautions when using electrical testing equipment. Failure to do so may result in electric shock, injury, or damage to the device or property.

  • Non superare i valori massimi di input specificati per ciascuna funzione di misurazione.
  • Assicurarsi che i cavi di prova siano in buone condizioni, privi di crepe o danni.
  • Non utilizzare il dispositivo se appare danneggiato o non funziona correttamente.
  • Scollegare sempre l'alimentazione dal circuito prima di effettuare misurazioni di resistenza o continuità.
  • Prestare attenzione quando si lavora con voltagsuperiori a 30 V CA RMS, 42 V di picco o 60 V CC, poiché rappresentano un rischio di scossa elettrica.
  • When using the Non-Contact Voltage (NCV) function, remember it is an indicator and not a substitute for direct voltage misurazione.

3. Impostazione

3.1. Disimballaggio e ispezione

Carefully remove the multimeter from its packaging. Inspect the device and accessories for any signs of damage. If any damage is found, do not use the device and contact customer support.

3.2. Installazione della batteria

The device requires two AAA batteries (included). To install or replace batteries:

  1. Individuare il coperchio del vano batteria sul retro del dispositivo.
  2. Utilizzare un piccolo cacciavite per aprire il vano batteria.
  3. Inserire due batterie AAA, assicurandosi della corretta polarità (+/-).
  4. Chiudere saldamente il coperchio del vano batterie.

3.3. Collegamento dei puntali di prova

The multimeter comes with a detachable test lead. The pen tip serves as the positive probe, while the black lead serves as the negative.

  1. Insert the black test lead into the 'Input COM' jack on the top of the multimeter.
  2. Prima dell'uso, assicurarsi che il collegamento sia saldo.
ALLmeter Multimeter Tester Pen with labeled components

Image 3.1: Diagram showing the components of the ALLmeter Multimeter Tester Pen, including the Input COM port for the test lead, Select key, LCD display, NCV/LIVE key, HOLD key, LED light, and Test pen tip.

ALLmeter Multimeter Tester Pen with test lead

Image 3.2: The ALLmeter Multimeter Tester Pen shown with its detachable black test lead, ready for use.

4. Istruzioni per l'uso

4.1. Accensione/spegnimento

Press the red 'Select' button to power on the device. The device will automatically enter 'Auto' mode. To power off, press and hold the 'Select' button until the display turns off. The device also features an automatic shutdown after 15 minutes of inactivity to conserve battery life.

4.2. Automatic Function (Auto Mode)

In 'Auto' mode, the multimeter intelligently identifies and measures AC/DC voltage, resistance, and continuity without manual range selection. This mode simplifies common electrical tasks.

Examples of automatic function display for DC voltage, AC voltage, e resistenza

Immagine 4.1: Es.amples of the LCD display in automatic function mode, showing measurements for DC voltage, AC voltage, and resistance (Ohm).

4.3. Selezione manuale delle funzioni

Press the 'Select' button repeatedly to cycle through manual measurement modes such as NCV, LIVE, Diode, and Frequency (Hz).

Examples of manual function display for NCV, LIVE, Diode, and Frequency

Immagine 4.2: Es.amples of the LCD display in manual function mode, showing indicators for NCV, LIVE wire detection, Diode testing, and Frequency measurement.

4.4. Vol. senza contattotage (NCV) Test

La funzione NCV consente il rilevamento sicuro della tensione CAtage without direct contact. This is ideal for identifying live wires in outlets, cables, or electrical panels.

  1. Press the 'NCV/LIVE' button to enter NCV mode. The display will show 'EF'.
  2. Bring the pen tip close to the object to be tested.
  3. An audible alarm and flashing LED light indicate the presence of AC voltage. The frequency of the alarm and light increases with stronger voltage segnali.
Multimeter pen detecting live and null wires in an electrical outlet and cable

Image 4.3: The multimeter pen demonstrating NCV detection on an electrical outlet and a cable, distinguishing between live and null wires with visual and audible alerts.

4.5. Rilevamento di cavi sotto tensione

The LIVE function helps distinguish between live and neutral wires in a circuit.

  1. Press the 'NCV/LIVE' button until 'LIVE' is displayed.
  2. Insert the pen tip into the terminal or touch the wire.
  3. A strong alarm and red light indicate a live wire. No alarm or a weaker signal indicates a neutral wire.
Multimeter pen detecting live wire in an electrical panel

Image 4.4: The multimeter pen being used to detect a live wire within an electrical panel, with the display showing 'LIVE' and an illuminated tip.

4.6. Funzione di conservazione dei dati

Premere il pulsante 'HOLD' per bloccare la lettura corrente sul display. Premerlo nuovamente per disattivare la funzione di blocco.

4.7. Torcia a LED

Press the 'LED Light' button to turn on the integrated flashlight for illumination in dimly lit areas. Press again to turn it off.

4.8. Dimostrazione video del prodotto

Watch this video for a visual guide on the functions and operation of the ALLmeter Multimeter Tester Pen.

Video 4.1: A demonstration of the ALLmeter 2-in-1 Pen Type Multimeter, showcasing its automatic function for measuring DC voltage, resistance, and diode, as well as its NCV and LIVE wire detection capabilities.

5. Manutenzione

Una corretta manutenzione garantisce la longevità e la precisione del multimetro.

  • Pulizia: Pulire il dispositivo con un panno asciutto e morbido. Non utilizzare detergenti abrasivi o solventi.
  • Magazzinaggio: Conservare il multimetro in un luogo fresco e asciutto, lontano dalla luce solare diretta e da temperature estreme. Se lo si conserva per un periodo prolungato, rimuovere le batterie per evitare perdite.
  • Sostituzione della batteria: Per garantire letture accurate, sostituire tempestivamente le batterie quando sul display compare l'indicatore di batteria scarica.

6. Risoluzione Dei Problemi

If you encounter issues with your ALLmeter Multimeter Tester Pen, refer to the following common troubleshooting steps:

  • Il dispositivo non si accende: Controllare che le batterie siano installate correttamente e abbiano una carica sufficiente. Sostituirle se necessario.
  • Letture imprecise: Ensure the test leads are securely connected. Verify that the correct measurement mode is selected for manual functions. Check battery level.
  • NCV/LIVE function not responding: Ensure the device is in the correct NCV or LIVE mode. The NCV function may be affected by external factors such as shielded wires or thick insulation.
  • Problemi di visualizzazione: If the display is dim or incomplete, replace the batteries.

For persistent issues, contact ALLmeter customer support.

7. Specifiche

CaratteristicaValore
Dimensioni del prodotto2.44 x 1.22 x 7.36 pollici
Numero modello articoloALLWT484-DEFBA
BatterieSono necessarie 2 batterie AAA (incluse)
ProduttoreTUTTImetro
Fonte di alimentazioneAlimentato a batteria
StileVoltage Tester Pen Type Multimeter
ColoreNero
Peso dell'articolo60 grammi (2.12 once)

7.1. Intervalli di misurazione

MisurazioneAllinearePrecisioneRisoluzione
Volume CC/CAtage (VCC/VCC)6V, 60V, 600V± (0.5% + 3)0.001V, 0.01V, 0.1V
Resistenza (Ω)600Ω, 6KΩ, 60KΩ, 600KΩ, 6MΩ, 60MΩ± (0.8%+5) (for 600Ω, 6KΩ, 60KΩ, 600KΩ)
± (1.2%+3) (for 6MΩ)
± (2.5%+3) (for 60MΩ)
0.1Ω, 1Ω, 10Ω, 100Ω, 1KΩ, 10KΩ
Frequenza (Hz)10-10M HZ± (2.0% + 3)0.1 Hz

8. Cosa c'è nella scatola

Il pacchetto del prodotto include:

  • 1 x ALLmeter Multimeter Tester Pen
  • 2 batterie AAA da 1.5 V
  • 1 x puntale

9. Garanzia e supporto

For warranty information or technical support, please refer to the official ALLmeter webo contattare il servizio clienti. Conservare la ricevuta d'acquisto per eventuali reclami in garanzia.

Documenti correlati - ALLWT484-DEFBA

Preview Manuale utente del multimetro intelligente a penna ALLmeter 6000 conteggi
Manuale utente per il multimetro intelligente a penna ALLmeter 6000 Counts. Copre oltreview, precauzioni di sicurezza, caratteristiche generali e tecniche, descrizione del pannello operativo, indicatori tecnici per DCV/ACV, resistenza e misurazioni dei diodi, risoluzione dei problemi e informazioni sulla garanzia.
Preview Manuale utente del misuratore di umidità induttivo senza pin
Istruzioni e specifiche per il misuratore di umidità induttivo senza puntali ALLmeter, uno strumento non invasivo per la misurazione dell'umidità in pareti, muratura, legno tenero e legno duro. Include caratteristiche, specifiche tecniche, precisione, funzionamento e tabelle di densità del legno.