1. Introduzione
This manual provides essential information for the proper installation, operation, maintenance, and troubleshooting of the Trane 12207310201376, 150-2050, 50M56-495-04, D345780P01 Ignition Control Board. This integrated furnace control board is designed to manage the ignition sequence and overall operation of compatible furnace systems. Please read this manual thoroughly before attempting any procedures.
2. Informazioni sulla sicurezza
ATTENZIONE: Rischio di scossa elettrica e pericolo di incendio.
- Installation and servicing must be performed by a qualified HVAC technician.
- Always disconnect power to the furnace before installing, servicing, or removing the control board.
- Assicurarsi che tutti i collegamenti elettrici siano sicuri e conformi alle normative elettriche locali.
- Non bypassare alcun dispositivo di sicurezza.
- Indossare adeguati dispositivi di protezione individuale (DPI) durante l'installazione e la manutenzione.
3. Prodotto finitoview
The Trane Ignition Control Board is a critical component responsible for controlling the ignition, flame sensing, and blower operations in a furnace. It integrates multiple functions into a single unit, ensuring efficient and safe furnace operation.

Image showing the Trane 12207310201376 Ignition Control Board, a green circuit board with various electronic components, relays, capacitors, and terminal blocks. Key markings like "150-2050" and "5172C" are visible on the board.
4. Configurazione e installazione
Installation of the control board should only be performed by a qualified HVAC technician. Incorrect installation can lead to equipment damage, personal injury, or fire.
4.1 Passaggi di pre-installazione
- Verify that the replacement board matches the original board's specifications and model numbers.
- Turn off all electrical power to the furnace at the main service panel.
- Label all wires connected to the existing control board for easy re-connection.
4.2 Procedura di installazione
- Scollegare con attenzione tutti i cavi dalla vecchia scheda di controllo.
- Remove the old control board from its mounting.
- Mount the new Trane control board securely in the same location.
- Connect all wires to the corresponding terminals on the new board, referring to your labels and the furnace wiring diagram. Ensure all connections are tight and secure.
- Verify all connections before restoring power.
5. Istruzioni per l'uso
The Trane Ignition Control Board operates automatically once installed correctly and power is restored to the furnace. It manages the sequence of operations for heating and cooling cycles based on thermostat demands.
5.1 Normal Operation Sequence (Heating)
- Il termostato richiede calore.
- Control board initiates the inducer motor.
- Pressure switch closes, signaling safe venting.
- Igniter is energized (if applicable, depending on ignition type).
- Gas valve opens, and burners ignite.
- Flame sensor confirms ignition.
- After a delay, the circulating blower motor starts.
- Furnace heats until thermostat setpoint is reached.
The board continuously monitors safety limits during operation.
6. Manutenzione
The Trane Ignition Control Board generally requires minimal maintenance. However, periodic inspection of the furnace system is recommended by a qualified technician.
- Ensure the furnace area is clean and free of dust and debris.
- During routine furnace maintenance, have a technician inspect the control board for any signs of wear, corrosion, or loose connections.
- Do not attempt to clean the board with liquids or abrasive materials.
7. Risoluzione Dei Problemi
Many furnace issues can be complex and require professional diagnosis. The following are general troubleshooting tips. Always disconnect power before inspecting components.
| Sintomo | Possibile causa | Azione |
|---|---|---|
| Furnace not starting | No power, thermostat issue, safety limit open, faulty board. | Check power supply, thermostat settings. Consult a technician for limit switch or board diagnosis. |
| Burners not igniting | No gas, faulty igniter, dirty flame sensor, faulty board. | Ensure gas supply is on. Clean flame sensor. If issues persist, contact a technician. |
| Il ventilatore non funziona | Faulty blower motor, capacitor, or control board. | Contattare un tecnico qualificato per la diagnosi e la riparazione. |
Many control boards have diagnostic LED lights that flash codes to indicate specific faults. Refer to your furnace's specific manual for interpreting these codes.
8. Specifiche
- Produttore: Trane
- Numeri di modello: 150-2050, 50M56-495-04, D345780P01
- Numero parte: 12207310201376, 5172C
- Tipo: Scheda di controllo del forno integrata
- Compatibilità: Designed for specific Trane furnace models. Verify compatibility with your furnace before purchase and installation.
9. Garanzia e supporto
For warranty information regarding your Trane Ignition Control Board, please refer to the documentation provided at the time of purchase or contact the seller/manufacturer directly. Warranty terms and conditions may vary.
For technical support, installation assistance, or complex troubleshooting, it is highly recommended to contact a certified HVAC professional or the official Trane customer support.