AOPUTTRIVER AP-9000B

Manuale utente del rilevatore di gas ammoniaca AOPUTTRIVER AP-9000B

Model: AP-9000B | Brand: AOPUTTRIVER

1. Introduzione

The AOPUTTRIVER AP-9000B is a high-precision ammonia gas detector designed for continuous quantitative analysis of ammonia (NH3) concentration. It features an imported electrochemical principle ammonia gas sensor, offering fast response speed, high accuracy, good stability, and excellent repeatability. This device is equipped with a large LCD display, sound and light dual alarms, and is USB rechargeable, making it suitable for various industrial and agricultural applications.

2. Caratteristiche del prodotto

AOPUTTRIVER AP-9000B Ammonia Gas Detector with its display showing various functions like data hold, color LCD, temperature/humidity display, dual sound/light alarm, Celsius/Fahrenheit switching, and USB rechargeable feature.

Figura 2.1: Oltreview of the AP-9000B Ammonia Gas Detector's key features.

3. Cosa c'è nella scatola

Dopo aver aperto la confezione, verificare che siano presenti tutti i seguenti elementi:

An image showing the contents of the AOPUTTRIVER AP-9000B Ammonia Gas Detector package: packing box, instruction manual, charging cable, 9000B Ammonia Tester, and storage bag.

Figure 3.1: Contents of the AP-9000B package.

4. Impostazione

4.1 Installazione della batteria

Before initial use, ensure the battery is correctly installed. If the battery is not pre-installed or needs replacement, follow these steps:

  1. Use a small screwdriver to unscrew the battery cover on the back of the device.
  2. Connect the battery to the interface inside the compartment.
  3. Tighten the battery cover securely.
A three-step guide showing how to install or replace the battery in the AOPUTTRIVER AP-9000B Ammonia Gas Detector: 1. Unscrew the battery cover, 2. Connect the battery, 3. Tighten the battery cover.

Figura 4.1: Fasi di installazione della batteria.

4.2 Ricarica del dispositivo

The AP-9000B is equipped with a rechargeable lithium battery. To charge the device:

  1. Individuare la porta di ricarica USB sul dispositivo.
  2. Connect the provided USB charging cable to the device and a suitable USB power source (e.g., computer, USB wall adapter).
  3. The battery indicator on the display will show the charging status. Charge until the battery icon indicates a full charge.
The AOPUTTRIVER AP-9000B Ammonia Gas Detector connected to a laptop via a USB cable for charging, with the display showing a charging indicator.

Figure 4.2: Charging the AP-9000B via USB.

5. Istruzioni per l'uso

5.1 Accensione/spegnimento

Il mio profilo

Il display LCD a colori fornisce informazioni in tempo reale:

Close-up of the AOPUTTRIVER AP-9000B Ammonia Gas Detector's color LCD display, showing ammonia concentration (NH3), current status, maximum value, temperature, and humidity readings. The device is held in a hand.

Figure 5.1: Main display interface of the AP-9000B.

5.3 Navigazione nel menu e impostazioni

The device features a menu for various settings and data review:

The settings interface includes options for:

Video 5.2: Demonstration of the AP-9000B's button functions and menu navigation for settings and data review.

6. Applicazioni

The AOPUTTRIVER AP-9000B Ammonia Gas Detector is versatile and can be used in a wide range of environments where ammonia monitoring is critical. Its applications include:

The AOPUTTRIVER AP-9000B Ammonia Gas Detector shown in various application environments: power station, mines, metallurgical industry, laboratory, farms, and fish ponds, illustrating its wide applicability.

Figure 6.1: Diverse applications of the AP-9000B Ammonia Gas Detector.

7. Safety Information: Hazards of Ammonia

Ammonia (NH3) is a hazardous gas. Understanding its concentration levels and associated risks is crucial for safety. The AP-9000B helps monitor these levels to prevent exposure to dangerous concentrations.

Ammonia Concentration Hazards
Concentration (PPM)Potenziale pericolo
5 ppmSensory odor threshold; some individuals may detect it.
20 ppmSignificant irritation in most people, generally not harmful with short exposure.
20-30 ppmTime-weighted safety thresholds for occupational exposure.
100 ppmDiscomfort for most people, not harmful with limited exposure.
250 ppmIrritation of nose, throat, eyes, and other senses.
400 ppmEye pain, tearing for 30 minutes.
700 ppmLimit of human tolerance; prolonged exposure should be avoided.
2500 ppmIntense coughing, irritation of nose, throat, etc.; may lead to death in 15 minutes.
5000 ppmCauses spasmodic dyspnea, asphyxiation, and rapid death.
A chart illustrating the hazards of ammonia at different PPM levels, from sensory odor threshold (5ppm) to levels causing severe health effects and rapid death (5000ppm), emphasizing safety protection.

Figure 7.1: Ammonia concentration hazard levels.

8. Manutenzione

To ensure the longevity and accuracy of your AOPUTTRIVER AP-9000B Ammonia Gas Detector, follow these maintenance guidelines:

9. Risoluzione Dei Problemi

If you encounter issues with your AP-9000B, refer to the following common troubleshooting steps:

For persistent issues not covered here, please contact AOPUTTRIVER customer support.

10. Specifiche

CaratteristicaSpecificazione
MarcaAOPUTTRIVER
Numero di modelloAP-9000B
Ammonia Measuring Range0 ~ 100 ppm
Risoluzione0.1 ppm
Precisione+/- 2%
Measurement Ambient Temperature RangeTemperatura -10 ~ 50 °C
Umidità di esercizio0-95% UR
Tipo di allarmeSound & Light Dual Alarm
Fonte di alimentazioneBatteria al litio ricaricabile tramite USB
Archiviazione dei datiUp to 180 sets of data (1-minute interval)
Peso dell'articolo3.2 once (circa 90.7 grammi)
Dimensioni del pacco8 x 6 x 3 pollici

11. Garanzia e supporto

Specific warranty information and detailed customer support contacts are not available in the provided product data. Please refer to the warranty card included with your product or visit the official AOPUTTRIVER websito per i termini di garanzia più aggiornati e le informazioni di contatto del servizio clienti.

Documenti correlati - AP-9000B

Preview Manuale utente e specifiche tecniche del rilevatore di gas ammoniaca AOPUTTRIVER AR8500
Manuale di istruzioni completo per il rilevatore di gas ammoniaca AOPUTTRIVER AR8500. Contiene la descrizione del prodotto, i parametri tecnici, il funzionamento, la manutenzione e le precauzioni di sicurezza per questo apparecchio di misurazione di precisione.
Preview Guida alla connessione Bluetooth AOPUTTRIVER AP-570C-APP
Istruzioni passo passo per la connessione dell'AOPUTTRIVER AP-570C-APP clamp misuratore al tuo smartphone tramite Bluetooth. Include suggerimenti per la risoluzione dei problemi per una configurazione senza problemi.
Preview Guida rapida - Termometro a infrarossi AOPUTTRIVER AP-2732
Inizia subito a usare il tuo termometro a infrarossi AOPUTTRIVER (AP-2732). Questa guida illustra l'installazione della batteria, il funzionamento di base e la comprensione delle letture del display per modelli come l'AP-2732.
Preview 6000 conteggi True-RMS Auto Range Intelligent Digital AC/DC Clamp Manuale operativo del multimetro
Questo documento fornisce il manuale operativo per il misuratore di corrente alternata/continua digitale intelligente AOPUTTRIVER 6000 conteggi True-RMS Auto Rangeamp Multimeter (Model AP-570S-APP), detailing its features, specifications, operating instructions, and companion AiLink mobile application.
Preview 7200APP DC/AC True-RMS Digital Clamp Manuale dell'utente del multimetro
Manuale utente per il convertitore di frequenza digitale AOPUTTRIVER 7200APP DC/AC True-RMSamp Multimetro. Questo misuratore a 6000 conteggi con regolazione automatica della portata misura amprabbia, voltage, capacità, continuità e resistenza, con connettività Bluetooth tramite l'app AILink. Include dettagli su sicurezza, funzionamento e manutenzione.