1. Introduzione

Thank you for choosing the KAIWEETS KC604 Digital Clamp Meter Multimeter. This device is designed for accurate and safe measurement of various electrical parameters, including AC/DC current, AC/DC voltage, temperature, capacitance, frequency, resistance, continuity, and diode testing. It features a unique D-shaped jaw for convenient clamping and non-contact voltagRilevamento e (NCV) per una maggiore sicurezza.

Safety Warning: Always read and understand all safety information and operating instructions before using this meter. This device is rated CAT III 600V. The screen will turn orange to warn when voltage supera 80 V o la corrente supera 1 A.

2. Cosa c'è nella scatola

  • KAIWEETS KC604 Clamp metro
  • Cavi di prova (rosso e nero)
  • Termocoppia
  • AAA Batteries (Pre-installed or included)
  • Custodia per il trasporto
  • Manuale d'uso
KAIWEETS KC604 Clamp Meter and included accessories: test leads, thermocouple, batteries, and carry case.

Figura 2.1: KAIWEETS KC604 Clamp Meter with all included accessories.

3. Caratteristiche del prodotto

3.1. TRUE-RMS AC/DC Clamp metro

This multimeter provides accurate True-RMS measurements for both AC and DC currents and voltages. It is equipped to measure a wide range of electrical parameters, making it suitable for various applications from household electrical systems to automotive and industrial troubleshooting.

Hand holding the KAIWEETS KC604 Clamp Meter measuring AC/DC current on a cable.

Figure 3.1: Measuring AC/DC Current with the D-shaped jaw.

Hand holding the KAIWEETS KC604 Clamp Misuratore di tensione AC/DCtage con puntali.

Figura 3.2: Misurazione del volume CA/CCtage utilizzando i cavi di prova.

Hand holding the KAIWEETS KC604 Clamp Meter measuring temperature with the thermocouple.

Figura 3.3: Misurazione della temperatura mediante la termocoppia inclusa.

3.2. D-Shaped Jaw Design

Unlike traditional clamp meters, the KC604 features a distinctive D-shaped jaw that can open up to 1.1 inches (2.87 cm). This design provides a convenient and secure way to clamp onto various cables, including larger diameter wires, for current measurements.

Close-up of the KAIWEETS KC604's D-shaped jaw, showing its opening capability and test lead storage.

Figure 3.4: The unique D-shaped jaw and integrated test lead storage.

3.3. NCV (Volume senza contattotage) Rilevamento

Il volume senza contattotage testing function allows you to detect AC voltage without direct circuit contact, enhancing safety. Simply press the NCV button and bring the meter close to the conductor. The device provides audible and visual alarms, with the buzzer frequency increasing come il volumetage signal strengthens.

KAIWEETS KC604 Clamp Meter performing NCV test, showing both low and high voltage indicazioni.

Figure 3.5: NCV detection indicating low and high voltage segnali.

3.4. Design intuitivo

The KC604 is designed with user convenience in mind. It features integrated test lead storage, an LCD backlight screen for clear readings in various lighting conditions, and a built-in flashlight for dimly lit areas. A low battery indicator prompts timely battery replacement, and the ammeter automatically shuts off after 15 minutes of inactivity to conserve power.

KAIWEETS KC604 Clamp Meter with its backlight and flashlight active in a dark environment.

Figure 3.6: LCD backlight and flashlight for improved visibility.

4. Impostazione

4.1. Installazione della batteria

  1. Assicurarsi che il misuratore sia spento.
  2. Individuare il coperchio del vano batterie sul retro del misuratore.
  3. Utilizzare un cacciavite per rimuovere la vite che fissa il coperchio della batteria.
  4. Insert the required AAA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
  5. Riposizionare il coperchio della batteria e fissarlo con la vite.

4.2. Collegamento dei puntali di prova

  1. Ensure the meter is turned OFF before connecting or disconnecting test leads.
  2. Inserire il puntale di prova nero nel jack di ingresso 'COM' (comune).
  3. Inserire il puntale di prova rosso nel jack di ingresso appropriato per la misurazione:
    • Per voltage, Resistance, Capacitance, Frequency, Diode, and Continuity measurements, insert into the 'VΩHz' jack.
    • For Current measurements using test leads (not clamp), refer to the specific current input jack if available (KC604 primarily uses clamp for current).
  4. Assicurarsi che i collegamenti siano saldi e sicuri.

5. Modalità operative

The KAIWEETS KC604 features a rotary dial to select different measurement functions. Turn the dial to the desired function before taking a measurement.

5.1. Misurazione della corrente CA/CC (Clamp)

  1. Turn the rotary dial to the '400A' or '40A' AC/DC current range.
  2. For DC current measurement, press the 'Z/F' button to zero the data before clamping.
  3. Aprire il clamp jaw and enclose only one conductor (not a bundle of wires) within the jaw.
  4. Leggere il valore corrente sul display LCD.
Diagramma che mostra i modi corretti e scorretti di usare il clamp metro per la misurazione della corrente.

Figure 5.1: Proper technique for current measurement using the clamp mascella.

5.2. Vol. AC/DCtage Misurazione

  1. Ruotare la manopola su 'V~' (Volume ACtage) o 'V=' (Volume DCtage) posizione.
  2. Connect the red test lead to the positive (+) point and the black test lead to the negative (-) or common point of the circuit.
  3. Leggi il vol.tage valore sul display LCD.

5.3. Resistance, Continuity, Diode, Capacitance, Frequency

These functions are typically grouped on the rotary dial. Select the appropriate symbol for your desired measurement:

  • Resistenza (Ω): Measures the electrical resistance of a component or circuit.
  • continuità (Simbolo di continuità): Checks for a complete circuit path with an audible beep for low resistance.
  • Diodo (Simbolo del diodo): Testa il volume in avantitagla caduta di un diodo.
  • Capacità (Capacitance symbol): Measures the capacitance of a capacitor.
  • Frequenza (Hz): Misura la frequenza di un segnale CA.

Connect the test leads across the component or circuit as appropriate for each measurement type.

6. Manutenzione

6.1. Pulizia

Per pulire il misuratore, pulire la custodia con un pannoamp panno e detergente delicato. Non utilizzare abrasivi o solventi. Assicurarsi che il misuratore sia completamente asciutto prima dell'uso.

6.2. Sostituzione della batteria

Quando sul display compare l'indicatore di batteria scarica, sostituire tempestivamente le batterie per garantire letture accurate. Seguire la procedura di installazione delle batterie nella Sezione 4.1.

6.3. Conservazione

When not in use for extended periods, remove the batteries to prevent leakage. Store the meter and its accessories in the provided carry case in a cool, dry place, away from direct sunlight and extreme temperatures.

7. Risoluzione Dei Problemi

  • Meter does not turn on or display is blank: Check battery installation and ensure batteries are not depleted. Replace if necessary. The auto-off feature may have activated; simply turn the dial or press a button to reactivate.
  • Letture imprecise: Ensure the correct measurement function is selected. Check test lead connections for firmness. Verify that the D-shaped jaw is properly closed around a single conductor for current measurements.
  • Continuity function does not beep: Ensure the test leads are making good contact with the circuit. The resistance may be too high for the continuity function to register.
  • NCV detection not working: Ensure the NCV function is selected and the top of the D-shaped jaw (where the sensor is located) is pointed towards the AC voltage fonte.

For more detailed troubleshooting or issues not listed here, please refer to the comprehensive manual included with your product or contact KAIWEETS customer support.

8. Specifiche

SpecificazioneValore
Dimensioni del prodotto7.62 x 3.11 x 1.36 pollici
Numero modello articoloIl KC604
ProduttoreKAIWEET - dolciumi
Fonte di alimentazioneAlimentato a batteria
StileCorrente AC / DC
ColoreRosso
Peso dell'articolo0.41 chilogrammi (14.46 once)

9. Garanzia e supporto

KAIWEETS provides 36 months of high-quality service and lifetime technical support for the KC604 Digital Clamp Meter. For any inquiries, technical assistance, or warranty claims, please contact KAIWEETS customer service through their official websito o rivenditore presso cui è stato acquistato il prodotto.

Si prega di conservare la prova d'acquisto ai fini della garanzia.

Documenti correlati - Il KC604

Preview KAIWEETS HT206D Digitale Clamp Manuale utente e specifiche del misuratore
Manuale utente completo per il cl digitale KAIWEETS HT206Damp misuratore. Include istruzioni dettagliate sul funzionamento, precauzioni di sicurezza, caratteristiche, specifiche e manutenzione per questo contatore AC/DC a gamma automatica T-RMS.amp metro.
Preview KAIWEETS HT206D True-RMS Digital Clamp Manuale utente del misuratore
Manuale utente completo per il KAIWEETS HT206D True-RMS Digital Clamp Misuratore. Scopri le sue caratteristiche, le informazioni sulla sicurezza, le istruzioni per l'uso e le specifiche per misurazioni elettriche accurate.
Preview Manuale utente del multimetro digitale KAIWEETS HT118A
Manuale utente completo per il multimetro digitale KAIWEETS HT118A, che comprende istruzioni di sicurezza, descrizione del prodotto, caratteristiche del multimetro, funzioni di misurazione e specifiche.
Preview Manuale utente del multimetro digitale intelligente Kaiweets KM601
Manuale utente completo per il multimetro digitale intelligente Kaiweets KM601, che comprende informazioni sulla sicurezza, caratteristiche del prodotto, modalità di misurazione (SMART e MANUALE), descrizioni dei terminali, manutenzione, specifiche e garanzia.
Preview KAIWEETS HT206B True-RMS Digital Clamp Manuale utente del misuratore
Manuale utente completo per il KAIWEETS HT206B True-RMS Digital Clamp Misuratore, che descrive in dettaglio le sue caratteristiche, le informazioni sulla sicurezza, le istruzioni per l'uso e le specifiche per varie misurazioni elettriche.
Preview KAIWEETS KC604 TRUE-RMS Digital Clamp Manuale utente del misuratore
Manuale utente per il convertitore digitale CA/CC KAIWEETS KC604 TRUE-RMS 400Aamp Misuratore. Questa guida descrive in dettaglio le caratteristiche, le precauzioni di sicurezza e le istruzioni operative per le misurazioni elettriche, comprese le funzioni True RMS, LPF, LowZ e NCV, in conformità con gli standard IEC 61010.