1. Introduzione
The DAYTECH Wireless Nurse Call System is designed to provide reliable and convenient communication between caregivers and individuals requiring assistance, such as the elderly, pregnant women, disabled individuals, or patients. This system enhances peace of mind by allowing quick and easy notification when help is needed, granting more freedom to both the caregiver and the person being cared for.

Figura 1.1: The DAYTECH Wireless Nurse Call System, including the main receiver unit and six compact call buttons.
2. Contenuto della confezione
Si prega di verificare che tutti gli articoli elencati di seguito siano inclusi nel pacchetto:
- 1 x unità di ricezione
- 6 x Call Buttons (each with a 12V 23A battery pre-installed)
- 1 x Manuale di istruzioni
- 6 nastri biadesivi

Figura 2.1: Dettagliato view of the receiver and call button components, highlighting their features and dimensions.
3. Impostazione
3.1 Configurazione del ricevitore
- Plug the receiver unit into a standard AC power outlet in a central location within your home or care facility.
- The receiver will power on and display a digital number, indicating it is ready for use.
3.2 Posizionamento del pulsante di chiamata
Each call button comes with a pre-installed 12V 23A battery. Use the provided double-sided adhesive tape to mount the call buttons in easily accessible locations for the user, such as beside a bed, in a bathroom, or near a chair.

Figura 3.1: The digital display on the receiver allows for easy identification of which call button has been activated, aiding in quick response.

Figura 3.2: Sopraview of the system's capabilities, including digital display, melody options, volume control, and waterproof design.
4. Istruzioni per l'uso
4.1 Effettuare una chiamata
To alert the caregiver, simply press the large call button on the transmitter unit. The receiver will emit a sound and display the corresponding number of the activated call button.

Figura 4.1: Pressing the call button to send an alert.
4.2 Regolazione del volume
The receiver offers 5 levels of volume adjustment, ranging from 0dB (mute) to 110dB. Use the volume control buttons on the side of the receiver to set your preferred alert level.

Figura 4.2: Volume levels and their typical sound environments, from quiet to very loud.

Figura 4.3: Location of the volume adjustment button on the receiver.
4.3 Melodie cangianti
The system features 38 selectable melodies. Use the forward and backward buttons on the side of the receiver to cycle through the available tunes and select your preferred alert sound.

Figura 4.4: Location of the melody selection buttons on the receiver.
4.4 Signal Range and Waterproofing
The wireless call bell has a reception range of up to 150 meters in open areas. It can easily transmit signals between floors in a typical house. The call buttons are designed with an IP55 waterproof rating, making them suitable for use in wet environments such as kitchens, toilets, and bathrooms.

Figura 4.5: Illustration of the system's effective communication range in various settings.

Figura 4.6: The IP55 waterproof design ensures durability and safe use in humid environments.
5. Manutenzione
5.1 Pulizia
Wipe the receiver and call buttons with a soft, dry cloth. Do not use abrasive cleaners or immerse the receiver in water. The call buttons are IP55 waterproof, but avoid prolonged submersion.
5.2 Sostituzione della batteria
The call buttons are powered by 12V 23A batteries. When a button's signal becomes weak or stops working, replace the battery. To replace, carefully open the call button casing, remove the old battery, and insert a new 12V 23A battery, ensuring correct polarity. Dispose of old batteries responsibly.
6. Risoluzione Dei Problemi
- No signal from call button: Ensure the call button's battery is not depleted. Replace if necessary. Check if the receiver is plugged in and powered on.
- Il ricevitore non suona: Check the volume level on the receiver. Ensure it is not set to 0dB (mute).
- Portata del segnale breve: Large metal objects, thick walls, or other wireless devices can interfere with the signal. Try repositioning the receiver or call buttons to minimize obstructions.
- Difficulty with settings: If you experience issues with melody or volume settings after a power outage or unplugging, refer to the setup section or perform a factory reset if available (refer to specific instructions in the included manual).
7. Specifiche
| Caratteristica | Specificazione |
|---|---|
| Marca | DAYTECH |
| Numero di modello | 1-CC16BL 6-1 |
| Peso del prodotto | 310 grammi |
| Dimensioni del pacco | Dimensioni: 11.1 x 9.2 x 9.1 cm |
| Componenti inclusi | 1 Receiver, 6 Transmitters (Call Buttons) |
| Batteria del pulsante di chiamata | 12V 23A (included) |
| Livelli di volume | 5 livelli (0-110 dB) |
| Melodie | 38 brani selezionabili |
| wireless Range | Fino a 150 m (area aperta) |
| Grado di impermeabilità | IP55 (for call buttons) |
| Espandibilità | Receiver supports up to 55 transmitters |
8. Garanzia e supporto
This DAYTECH product comes with a lifetime quality guarantee from the date of purchase. We are committed to ensuring your satisfaction. If you encounter any issues or have questions regarding the use, maintenance, or performance of your Wireless Nurse Call System, please do not hesitate to contact our customer support for prompt assistance.
For support, please refer to the contact information provided with your purchase or visit the official DAYTECH websito.