Solax Power X1-Boost-3.0-G3

Manuale utente dell'inverter solare Solax Power X1-Boost-3.0-G3

Model: X1-Boost-3.0-G3

1. Introduzione

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Solax Power X1-Boost-3.0-G3 grid-tied solar inverter. This device is designed to convert direct current (DC) electricity generated by solar panels into alternating current (AC) electricity for household consumption or export to the electrical grid. Please read this manual thoroughly before installation and retain it for future reference.

Key features of the X1-Boost-3.0-G3 include:

  • Ottimizzazione energetica: Equipped with 2 Maximum Power Point Trackers (MPPTs) to manage multiple solar panel orientations and optimize energy production.
  • Elevata affidabilità: Engineered for durability and stable operation, incorporating integrated protections for safe and continuous performance.
  • Monitoraggio remoto: Connectivity options enable convenient monitoring and management of the solar system from various locations.

2. Informazioni sulla sicurezza

Strict adherence to all safety instructions is mandatory to prevent electric shock, fire, injury, or damage to the inverter. Only qualified and authorized personnel should perform installation and maintenance procedures.

PERICOLO!

  • Alto volumetages are present within the inverter. All work must be carried out by a qualified electrician.
  • This appliance is not intended for use by children or persons with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction.
  • I bambini devono essere sorvegliati per assicurarsi che non giochino con l'apparecchio.

ATTENZIONE!

  • Risk of burn injuries due to hot enclosure parts. During operation, the upper lid and body of the enclosure may become hot. Only touch the lower enclosure lid during operation.
  • Possible damage to health as a result of radiation effects. Do not stay closer than 20 cm to the inverter for any length of time.

AVVERTIMENTO!

  • Do not operate the inverter when the device is running abnormally.
  • Rischio di scossa elettrica!
  • Volumi pericolositage will be present for up to 5 minutes after disconnection from the power supply.
  • Garantire ingresso DC voltage is below the maximum DC voltage specified. Overvoltage can cause permanent damage to the inverter and other losses, which are not covered by warranty.
  • Authorized service personnel must disconnect both AC and DC power from the X1 series inverter before attempting any maintenance, cleaning, or work on connected circuits.

NOTA!

  • Grounding the PV generator is essential. Comply with local requirements for grounding PV modules and the PV generator. Solax recommends connecting the generator frame and other electrically conductive surfaces to ensure continuous conduction and proper grounding for optimal system and personal protection.

Linee guida generali sulla sicurezza:

  • Read this entire manual carefully before installation and operation. Keep it for future reference.
  • Use only attachments recommended or sold by Solax. Using unapproved attachments may result in fire, electric shock, or injury.
  • Ensure existing wiring is in good condition and appropriately sized.
  • Do not disassemble any parts of the inverter not mentioned in the installation guide. It contains no user-serviceable parts. Attempting to service the inverter yourself will void the warranty and may result in electric shock or fire.
  • Keep the inverter away from flammable or explosive materials.
  • The installation location should be free from humidity and corrosive substances.
  • Il personale di servizio autorizzato deve utilizzare strumenti isolati durante l'installazione o il lavoro con questa apparecchiatura.
  • PV modules must have an IEC 61730 Class A rating.
  • Never touch both the positive and negative poles of the PV connecting device simultaneously.
  • L'unità contiene condensatori che rimangono carichi a un volume potenzialmente letaletage even after the MAINS and PV supply have been disconnected. Always wait 5 minutes after switching off PV and Mains before unplugging DC and MAINS couplers.
  • When accessing the internal circuit, wait 5 minutes for capacitors to discharge. Measure the voltage between UDC+ and UDC- terminals with a multi-meter (impedance at least 1Mohm) to confirm total discharge.
Safety warnings from the Solax Power X1-Boost-3.0-G3 inverter manual

Image: Detailed safety warnings and precautions for the Solax Power X1-Boost-3.0-G3 inverter, emphasizing high voltage risks, qualified personnel requirements, and proper handling procedures.

3. Prodotto finitoview

The Solax Power X1-Boost-3.0-G3 inverter features a compact and robust design, optimized for residential solar installations. Its intuitive interface allows for easy monitoring and control.

Davanti view of the Solax Power X1-Boost-3.0-G3 solar inverter

Immagine: Frontale view of the Solax Power X1-Boost-3.0-G3 solar inverter, showcasing il suo bianco casing e display digitale.

Solax Power X1-Boost-3.0-G3 inverter highlighting 3.0kW, 2MPPT, 14A specifications

Image: The Solax Power X1-Boost-3.0-G3 inverter with callouts for 3.0kW power, 2 MPPTs, and 14A input current.

3.1 Caratteristiche principali

  • Prestazioni superiori: Features 150% oversizing and 110% overload capacity, with a 14A DC input per string.
  • Facile da usare: Offers optional 24-hour monitoring and maintenance, designed for easy installation and configuration.
  • Guaranteed Reliability and Security: Includes optional integrated Type III AC/DC Surge Protection Device (SPD), overheating protection, and an integrated export control function.
Diagram illustrating key features of the Solax Power X1-Boost-3.0-G3 inverter

Image: Visual representation of the Solax Power X1-Boost-3.0-G3 inverter's key features, including superior performance, user-friendliness, and guaranteed reliability.

4. Installazione e configurazione

Installation of the Solax Power X1-Boost-3.0-G3 inverter must be performed by a qualified electrician in accordance with all local and national electrical codes and regulations.

4.1 Montaggio

Select a suitable mounting location that is:

  • Protetto dalla luce solare diretta, dalla pioggia e dalle temperature estreme.
  • Ben ventilato per garantire una corretta dissipazione del calore.
  • Accessible for maintenance but secure from unauthorized access.
  • Lontano da materiali infiammabili o esplosivi.

4.2 collegamenti elettrici

The inverter requires connections for:

  • Ingresso CC: From the solar PV array. Ensure correct polarity and voltage livelli.
  • Uscita CA: To the electrical grid or household load.
  • Messa a terra: Proper grounding of the inverter and PV array is critical for safety.

Refer to the detailed wiring diagrams provided in the full installation guide for specific connection instructions.

4.3 Connectivity and Monitoring

The inverter supports remote monitoring capabilities. This typically involves connecting the inverter to a local network (e.g., Wi-Fi or Ethernet) to transmit performance data to a dedicated online portal or mobile application. This allows for 24-hour monitoring of energy production and system status.

Diagram showing advanced features like remote updates, 150% oversizing, 14A DC input, built-in SPD, CT sensor support, zero injection control, easy installation, and 24h monitoring for Solax Power X1-Boost-3.0-G3

Immagine: Oltreview of advanced features for the Solax Power X1-Boost-3.0-G3, including remote updates, high oversizing/overload, built-in safety, and comprehensive monitoring.

5. Funzionamento

Once installed and connected, the Solax Power X1-Boost-3.0-G3 inverter will automatically begin operation when sufficient solar power is available and grid conditions are met. The integrated display provides real-time information on system performance.

5.1 Avvio dell'inverter

  1. Ensure all DC and AC connections are secure and correctly wired.
  2. Switch on the DC isolator switch (if present) for the PV array.
  3. Switch on the AC circuit breaker for the inverter.
  4. The inverter will perform a self-test and then begin converting solar energy.

5.2 Monitoraggio delle prestazioni

The inverter's front panel display shows operational data such as current power output, daily energy yield, and system status. For more detailed monitoring, utilize the remote monitoring platform accessible via web o applicazione mobile.

6. Manutenzione

Regular maintenance ensures the longevity and optimal performance of your Solax Power X1-Boost-3.0-G3 inverter. Always disconnect both AC and DC power supplies and wait 5 minutes before performing any maintenance.

6.1 Controlli di routine

  • Ispezione visiva: Periodically check the inverter for any visible damage, corrosion, or loose connections.
  • Pulizia: Mantenere le aperture di ventilazione dell'inverter libere da polvere e detriti per garantire un raffreddamento adeguato. Utilizzare un panno morbido e asciutto per pulire l'esterno. Non utilizzare liquidi o detergenti abrasivi.
  • Integrità del cavo: Inspect all cables for signs of wear, damage, or degradation.

6.2 Manutenzione professionale

It is recommended to have the inverter inspected by a qualified technician at least once every few years to ensure all components are functioning correctly and to perform any necessary firmware updates.

7. Risoluzione Dei Problemi

Questa sezione fornisce le procedure di base per la risoluzione dei problemi più comuni. Per problemi più complessi, contattare personale di assistenza qualificato.

7.1 Problemi comuni e soluzioni

  • L'inverter non produce energia:
    • Check if the DC isolator and AC circuit breaker are switched ON.
    • Verificare che i pannelli solari ricevano sufficiente luce solare.
    • Check for any error messages on the inverter display or monitoring platform.
  • Error Message Displayed:
    • Note down the error code. Refer to the full user manual or contact technical support with the code for specific guidance.
    • Attempt a system restart by switching off AC and DC power, waiting 5 minutes, then switching them back on.
  • Bassa potenza in uscita:
    • Ensure solar panels are clean and free from shading.
    • Check for any loose or damaged DC connections.
    • Verify that the inverter's ventilation is not obstructed.

If the issue persists after attempting these steps, contact Solax Power technical support or your installer.

8. Specifiche

The following table outlines the technical specifications for the Solax Power X1-Boost-3.0-G3 solar inverter.

Technical specifications of the Solax Power X1-Boost-3.0-G3 inverter, including voltage, current, MPPTs, and temperature range

Image: Technical specifications for the Solax Power X1-Boost-3.0-G3 inverter, detailing electrical parameters and operating conditions.

AttributoValore
MarcaSolax Power (Distributed by Solitia)
Nome del modelloX1-Boost-3.0-G3
Numero di modello (articolo)GRI0034
Energia3 kW
Voltage230 Volt
Ingresso volumetage (CA)230 Volt
massimo Ingresso FV Voltage600V
Corrente massima di ingresso FV14A/14A
Numero di inseguitori MPPT2
Strings per MPPT Tracker1
Intervallo di temperatura ambiente di funzionamentoda -25°C a +60°C
ColoreBianco
Dimensioni (L x P x A)43.9 cm x 51.4 cm x 23.3 cm (17.3 pollici x 20.2 pollici x 9.2 pollici)
Peso13.5 kg (29.7 libbre)
Uso consigliatoCasa
Fonte di alimentazioneEnergia solare
Numero totale di prese di corrente1
Disponibilità dei pezzi di ricambio3 anni
Aggiornamenti software garantiti fino alInformazioni non disponibili
Dimensions and weight of the Solax Power X1-Boost-3.0-G3 inverter

Image: Physical dimensions and weight of the Solax Power X1-Boost-3.0-G3 inverter, indicating its compact size.

9. Garanzia e supporto

The Solax Power X1-Boost-3.0-G3 inverter is designed for reliability and comes with a commitment to quality. Spare parts are available for a period of 3 years from the date of purchase.

For detailed warranty terms and conditions, please refer to the official warranty document provided with your product or visit the Solax Power websito. La garanzia copre in genere i difetti di materiali e di fabbricazione in condizioni di normale utilizzo.

For technical support, service requests, or further inquiries, please contact your authorized Solax Power distributor or installer. Ensure you have your product model number (X1-Boost-3.0-G3) and serial number ready when contacting support.

Documenti correlati - X1-Boost-3.0-G3

Preview Manuale utente SolaX X1-BOOST G4: inverter solari monofase da 2.5 kW a 6 kW
Comprehensive user manual for the SolaX X1-BOOST G4 series of single-phase solar inverters, covering models from 2.5kW to 6kW. Details installation, operation, safety, technical data, and troubleshooting for optimal PV system performance.
Preview Manuale utente della serie SolaX X1-BOOST G4: installazione, funzionamento e risoluzione dei problemi
Manuale utente completo per gli inverter solari SolaX X1-BOOST serie G4 (da 2.5 kW a 6 kW). Include informazioni su installazione, sicurezza, dati tecnici, funzionamento, risoluzione dei problemi e garanzia per prestazioni ottimali dell'impianto fotovoltaico.
Preview Manuale utente della serie SolaX X1-VAST: inverter solari da 5-10 kW
Manuale utente per la serie SolaX X1-VAST di inverter solari connessi alla rete da 5 kW, 6 kW, 8 kW e 10 kW con capacità di accumulo di energia. ...
Preview Manuale utente SolaX X1-AC 3.0kW - 5.0kW
Manuale utente completo per gli inverter solari della serie SolaX X1-AC (da 3.0 kW a 5.0 kW), che copre installazione, collegamento elettrico, specifiche tecniche, impostazioni, aggiornamenti del firmware, risoluzione dei problemi e manutenzione.
Preview SolaX X1-Lite-LV Series Installation Manual: 8kW, 10kW, 12kW Inverters
Comprehensive installation manual for the SolaX X1-Lite-LV series solar energy storage inverters (8kW, 10kW, 12kW models). Covers safety, product overview, preparation, installation, electrical connection, commissioning, operation, and troubleshooting for PV grid-connected systems.
Preview Manuale utente e guida all'installazione della serie SolaX X1-Hybrid
Manuale utente completo per gli inverter solari ibridi SolaX X1-Hybrid Series (G4). Include installazione, specifiche tecniche, collegamenti elettrici, modalità di funzionamento, risoluzione dei problemi e manutenzione per i modelli da 3.0 kW a 7.5 kW.