KAIWEETS HT208F

KAIWEETS HT208F Digital Clamp Manuale utente del misuratore

Modello: HT208F

1. Introduzione

The KAIWEETS HT208F is a True-RMS Digital Clamp Meter designed for accurate electrical measurements in various environments, including laboratories, factories, and households. It offers a wide range of functions to meet diverse testing needs.

Le principali funzionalità includono:

KAIWEETS HT208F Digital Clamp metro

Figure 1.1: KAIWEETS HT208F Digital Clamp metro

This image displays the KAIWEETS HT208F Digital Clamp Meter, highlighting its compact design and clear display, ready for various electrical measurements.

2. Informazioni sulla sicurezza

Always adhere to safety precautions when operating the KAIWEETS HT208F Digital Clamp Meter to prevent electric shock or damage to the device. This meter complies with safety standards IEC 61010-1, CAT IV 600V, and CAT III 1000V, featuring double insulation for enhanced protection.

Linee guida generali sulla sicurezza:

3. Prodotto finitoview e componenti

The KAIWEETS HT208F comes with essential accessories for immediate use. Familiarize yourself with the main components of the device.

Cosa c'è nella scatola:

KAIWEETS HT208F Components

Figure 3.1: Included Components of the HT208F

This image illustrates the contents of the KAIWEETS HT208F package, including the clamp meter, test leads, thermocouples, batteries, and the user manual.

Main Parts of the Clamp Misuratore:

  1. Clamp Mascella: Utilizzato per la misurazione della corrente CA/CC senza contatto.
  2. Quadrante rotante: Seleziona la funzione di misurazione desiderata.
  3. Schermo LCD: Mostra le letture delle misurazioni, le unità e gli indicatori di funzione.
  4. Pulsanti funzione: Include buttons for FUNC (function selection), RAN (range), MAX/MIN (maximum/minimum value), REL/ZERO (relative/zero mode), and HOLD (data hold).
  5. Jack di ingresso: COM (comune), VΩmA (voltage, resistance, capacitance, diode, continuity, temperature), and 1000A (for high current measurements with test leads, if applicable).
  6. Sensore NCV: Located at the top of the clamp per volume senza contattotage rilevamento.
  7. Torcia elettrica: Integrated light for illuminating dimly lit work areas.

4. Impostazione

4.1 Installazione della batteria

The KAIWEETS HT208F requires 3 AAA batteries for operation. These are typically included. To install or replace batteries:

  1. Assicurarsi che il misuratore sia spento.
  2. Individuare il vano batterie sul retro del misuratore.
  3. Use a screwdriver to remove the screws securing the battery cover.
  4. Inserire le 3 batterie AAA rispettando la polarità corretta (+/-) come indicato all'interno del vano.
  5. Riposizionare il coperchio della batteria e fissarlo con le viti.

4.2 Connecting Test Leads and Thermocouples

Per la maggior parte delle misurazioni (voltage, resistance, continuity, etc.), connect the test leads:

For temperature measurements, connect the thermocouple:

5. Istruzioni per l'uso

5.1 Funzionamento generale

Easy Use in Dimly Lit Places

Figure 5.1: Using the Flashlight in Low Light

This image demonstrates the KAIWEETS HT208F being used in a dimly lit electrical panel, with its integrated flashlight illuminating the work area for clear visibility.

5.2 Modalità di misurazione

Misurazione della corrente AC/DC (Clamp)

To measure AC or DC current using the clamp mascella:

  1. Rotate the dial to the AC A or DC A position.
  2. Aprire il clamp jaw and enclose only uno conductor (wire) through the center of the clamp.
  3. Read the current value on the display. For DC current, press the REL/ZERO button to zero the reading before measurement if needed.
Test corrente CA/CC

Figura 5.2: Misurazione della corrente CA/CC

This image shows the clamp meter measuring current by enclosing a single wire, demonstrating its non-contact current measurement capability.

Volume AC/DCtage Misurazione

Per misurare il volume AC o DCtage:

  1. Rotate the dial to the AC V or DC V position.
  2. Collegare i puntali di prova ai punti del circuito in cui la tensione ètage deve essere misurato.
  3. Leggi il vol.tage valore sul display.
Volume AC/DCtage Prova

Figura 5.3: Vol. AC/DCtage Misurazione

This image illustrates the clamp meter performing a voltage test using its test leads, showing the display with a voltage lettura.

Resistance, Capacitance, Diode, Continuity

Rotate the dial to the Ω (Ohms) or Capacitance symbol. Use the FUNC button to cycle through Resistance, Diode, and Continuity modes. Connect test leads to the component being measured.

Misurazione della temperatura

Rotate the dial to the °C/°F position. Connect the thermocouple to the input jacks. Place the thermocouple tip on the object or area whose temperature is to be measured.

NCV (Volume senza contattotage) Rilevamento

Rotate the dial to the NCV position. Move the top of the clamp misuratore vicino a un conduttore sotto tensione. Il misuratore indicherà la presenza di tensione alternatatage through audible beeps and visual indicators on the display.

Misurazione della corrente di spunto

The Inrush function is used to measure the initial surge of current when an electrical device is turned on. This function is only available in AC current mode.

  1. Rotate the dial to the AC A position.
  2. Press the Inrush button.
  3. Aprire il clamp jaw and enclose the single conductor of the device to be tested.
  4. Turn on the device. The meter will capture and display the peak inrush current. The measuring time is approximately 100ms. This function works best when the current is greater than 10A.
Inrush Current Test

Figure 5.4: Inrush Current Test in AC Mode

This image shows the clamp meter performing an inrush current test on an electrical circuit, with the display showing the measured inrush value.

VFD (Variable Frequency Drive) and LoZ (Low Input Impedance) Modes

These advanced modes provide higher accuracy for specific measurement scenarios:

Advanced Functions VFD and LoZ

Figure 5.5: Advanced Measurement Functions (VFD and LoZ)

This image illustrates the application of advanced functions like VFD for motor drive measurements and LoZ for reducing interference, showcasing the meter's versatility.

5.3 Guida video operativa

For a visual demonstration of the KAIWEETS HT208F's features and operation, please refer to the official product video below:

Video 5.1: KAIWEETS Inrush Digital Clamp Meter with Backlit

Questo video fornisce una panoramica completaview and demonstration of the KAIWEETS HT208F Digital Clamp Misuratore, mostraasing its various measurement capabilities including Inrush current, continuity, diode, resistance, capacitance, AC voltage, AC current, NCV, DC voltage, and temperature measurement.

6. Manutenzione

6.1 Pulizia del dispositivo

Per garantire la longevità e la precisione del tuo clamp metro:

6.2 Sostituzione della batteria

Replace the batteries as described in Section 4.1 when the low battery indicator appears on the display. Prompt battery replacement ensures continued accurate operation.

6.3 Conservazione

When not in use for extended periods, store the meter in a dry, cool environment, away from direct sunlight and extreme temperatures. If storing for a long time, it is recommended to remove the batteries to prevent leakage.

7. Risoluzione Dei Problemi

If you encounter issues with your KAIWEETS HT208F, refer to the following common troubleshooting steps:

For persistent issues or specific error codes not covered here, please contact KAIWEETS customer service.

8. Specifiche

CaratteristicaSpecificazione
Numero di modelloXSC-US-HT208F
Dimensioni del prodotto11.22 x 2.44 x 5.39 pollici
Peso1.72 libbre
Fonte di alimentazioneAlimentato a batteria (3 batterie AAA incluse)
Visualizza i conteggi6000 Counts TRMS
Gamma di corrente CA/CCFino a 1000 Amp
Volume AC/DCtage GammaFino a 1000V
Valutazione di sicurezzaIEC 61010-1, CAT IV 600V, CAT III 1000V
Caratteristiche specialiInrush Current, NCV, VFD, LoZ, Backlight, Flashlight
ColoreRosso

9. Garanzia e supporto

KAIWEETS fornisce un 36-Month product service for the HT208F Digital Clamp Meter, ensuring long-term reliability and customer satisfaction.

For any inquiries, technical assistance, or service requests, KAIWEETS offers Servizio clienti 7/24. Please refer to the contact information provided in your product packaging or visit the official KAIWEETS websito per i dettagli del supporto.

Documenti correlati - Tipo di elemento: HT208F

Preview KAIWEETS HT208D True-RMS Digital Clamp Manuale utente del misuratore
Manuale utente completo per il KAIWEETS HT208D True-RMS Digital Clamp Misuratore. Scopri le sue caratteristiche, le informazioni sulla sicurezza, le istruzioni per l'uso e le specifiche per la misurazione della corrente CA/CC, del voltage, frequenza, resistenza, capacità e temperatura.
Preview KAIWEETS HT208D True-rms Digital Clamp Manuale utente del misuratore
Manuale di utilizzo del multimetro a pin numerico KAIWEETS HT208D, incluse le caratteristiche, le funzioni avanzate, le specifiche tecniche e le istruzioni di sicurezza.
Preview KAIWEETS HT208D True-rms Digital Clamp Manuale utente del misuratore
Manuale utente completo per il KAIWEETS HT208D True-rms Digital Clamp Misuratore, caratteristiche di copertura, sicurezza, funzionamento e specifiche per corrente CA/CC, vol.tage, frequenza, resistenza e altro ancora.
Preview KAIWEETS HT206D Digitale Clamp Manuale utente e specifiche del misuratore
Manuale utente completo per il cl digitale KAIWEETS HT206Damp misuratore. Include istruzioni dettagliate sul funzionamento, precauzioni di sicurezza, caratteristiche, specifiche e manutenzione per questo contatore AC/DC a gamma automatica T-RMS.amp metro.
Preview Manuale utente del multimetro digitale KAIWEETS HT118A
Manuale utente completo per il multimetro digitale KAIWEETS HT118A, che comprende istruzioni di sicurezza, descrizione del prodotto, caratteristiche del multimetro, funzioni di misurazione e specifiche.
Preview KAIWEETS HT206D True-RMS Digital Clamp Manuale utente del misuratore
Manuale utente completo per il KAIWEETS HT206D True-RMS Digital Clamp Misuratore. Scopri le sue caratteristiche, le informazioni sulla sicurezza, le istruzioni per l'uso e le specifiche per misurazioni elettriche accurate.