1. Introduzione
The KAIWEETS HT208F is a True-RMS Digital Clamp Meter designed for accurate electrical measurements in various environments, including laboratories, factories, and households. It offers a wide range of functions to meet diverse testing needs.
Le principali funzionalità includono:
- Accurate measurement of 1000 Amp AC/DC Current and 1000V AC/DC Voltage.
- Measurement of Frequency, Duty Cycle, Resistance, Capacitance, Diode, Continuity, and Temperature.
- Inrush Current measurement for diagnosing startup problems in motors and circuits.
- Volume senza contattotage (NCV) detection for quick voltage controlli di presenza.
- Built-in flashlight and upgraded backlit screen for improved visibility in various lighting conditions.
- Advanced Variable Frequency Drive Filtering (VFD) and Low Input Impedance (LoZ) modes for higher accuracy.

Figure 1.1: KAIWEETS HT208F Digital Clamp metro
This image displays the KAIWEETS HT208F Digital Clamp Meter, highlighting its compact design and clear display, ready for various electrical measurements.
2. Informazioni sulla sicurezza
Always adhere to safety precautions when operating the KAIWEETS HT208F Digital Clamp Meter to prevent electric shock or damage to the device. This meter complies with safety standards IEC 61010-1, CAT IV 600V, and CAT III 1000V, featuring double insulation for enhanced protection.
Linee guida generali sulla sicurezza:
- Non utilizzare il misuratore se appare danneggiato o se l'isolamento dei puntali di prova è compromesso.
- Prima di collegare i puntali di prova, assicurarsi che il commutatore rotante sia nella posizione corretta per la misurazione desiderata.
- Non superare i valori massimi di input per nessuna funzione.
- Prestare la massima attenzione quando si lavora su circuiti sotto tensione.
- Durante le misurazioni, tenere le dita dietro le apposite protezioni sui cavi di prova.
- Per garantire letture accurate, sostituire tempestivamente le batterie quando compare l'indicatore di batteria scarica.
3. Prodotto finitoview e componenti
The KAIWEETS HT208F comes with essential accessories for immediate use. Familiarize yourself with the main components of the device.
Cosa c'è nella scatola:
- KAIWEETS HT208F Clamp metro
- Cavi di prova (rosso e nero)
- Thermocouples (for temperature measurement)
- 3 batterie AAA (preinstallate o incluse separatamente)
- Manuale d'uso

Figure 3.1: Included Components of the HT208F
This image illustrates the contents of the KAIWEETS HT208F package, including the clamp meter, test leads, thermocouples, batteries, and the user manual.
Main Parts of the Clamp Misuratore:
- Clamp Mascella: Utilizzato per la misurazione della corrente CA/CC senza contatto.
- Quadrante rotante: Seleziona la funzione di misurazione desiderata.
- Schermo LCD: Mostra le letture delle misurazioni, le unità e gli indicatori di funzione.
- Pulsanti funzione: Include buttons for FUNC (function selection), RAN (range), MAX/MIN (maximum/minimum value), REL/ZERO (relative/zero mode), and HOLD (data hold).
- Jack di ingresso: COM (comune), VΩmA (voltage, resistance, capacitance, diode, continuity, temperature), and 1000A (for high current measurements with test leads, if applicable).
- Sensore NCV: Located at the top of the clamp per volume senza contattotage rilevamento.
- Torcia elettrica: Integrated light for illuminating dimly lit work areas.
4. Impostazione
4.1 Installazione della batteria
The KAIWEETS HT208F requires 3 AAA batteries for operation. These are typically included. To install or replace batteries:
- Assicurarsi che il misuratore sia spento.
- Individuare il vano batterie sul retro del misuratore.
- Use a screwdriver to remove the screws securing the battery cover.
- Inserire le 3 batterie AAA rispettando la polarità corretta (+/-) come indicato all'interno del vano.
- Riposizionare il coperchio della batteria e fissarlo con le viti.
4.2 Connecting Test Leads and Thermocouples
Per la maggior parte delle misurazioni (voltage, resistance, continuity, etc.), connect the test leads:
- Inserire il nero puntale di prova nel COM jack di ingresso (comune).
- Inserire il rosso puntale di prova nel VΩmA jack di ingresso per voltage misure di resistenza, capacità, diodi e continuità.
For temperature measurements, connect the thermocouple:
- Insert the thermocouple into the appropriate input jacks, observing polarity.
5. Istruzioni per l'uso
5.1 Funzionamento generale
- Accensione/spegnimento: Rotate the dial from the OFF position to any measurement function to turn the meter ON. Rotate back to OFF to power down.
- Gamma automatica: The meter automatically selects the appropriate measurement range for most functions.
- Retroilluminazione/Torcia: Press the dedicated button (often labeled with a light bulb icon) to activate the display backlight or the integrated flashlight. This feature is particularly useful in dimly lit environments.

Figure 5.1: Using the Flashlight in Low Light
This image demonstrates the KAIWEETS HT208F being used in a dimly lit electrical panel, with its integrated flashlight illuminating the work area for clear visibility.
5.2 Modalità di misurazione
Misurazione della corrente AC/DC (Clamp)
To measure AC or DC current using the clamp mascella:
- Rotate the dial to the AC A or DC A position.
- Aprire il clamp jaw and enclose only uno conductor (wire) through the center of the clamp.
- Read the current value on the display. For DC current, press the REL/ZERO button to zero the reading before measurement if needed.

Figura 5.2: Misurazione della corrente CA/CC
This image shows the clamp meter measuring current by enclosing a single wire, demonstrating its non-contact current measurement capability.
Volume AC/DCtage Misurazione
Per misurare il volume AC o DCtage:
- Rotate the dial to the AC V or DC V position.
- Collegare i puntali di prova ai punti del circuito in cui la tensione ètage deve essere misurato.
- Leggi il vol.tage valore sul display.

Figura 5.3: Vol. AC/DCtage Misurazione
This image illustrates the clamp meter performing a voltage test using its test leads, showing the display with a voltage lettura.
Resistance, Capacitance, Diode, Continuity
Rotate the dial to the Ω (Ohms) or Capacitance symbol. Use the FUNC button to cycle through Resistance, Diode, and Continuity modes. Connect test leads to the component being measured.
Misurazione della temperatura
Rotate the dial to the °C/°F position. Connect the thermocouple to the input jacks. Place the thermocouple tip on the object or area whose temperature is to be measured.
NCV (Volume senza contattotage) Rilevamento
Rotate the dial to the NCV position. Move the top of the clamp misuratore vicino a un conduttore sotto tensione. Il misuratore indicherà la presenza di tensione alternatatage through audible beeps and visual indicators on the display.
Misurazione della corrente di spunto
The Inrush function is used to measure the initial surge of current when an electrical device is turned on. This function is only available in AC current mode.
- Rotate the dial to the AC A position.
- Press the Inrush button.
- Aprire il clamp jaw and enclose the single conductor of the device to be tested.
- Turn on the device. The meter will capture and display the peak inrush current. The measuring time is approximately 100ms. This function works best when the current is greater than 10A.

Figure 5.4: Inrush Current Test in AC Mode
This image shows the clamp meter performing an inrush current test on an electrical circuit, with the display showing the measured inrush value.
VFD (Variable Frequency Drive) and LoZ (Low Input Impedance) Modes
These advanced modes provide higher accuracy for specific measurement scenarios:
- VFD: Used for accurate voltage and current measurements on variable frequency motor drives.
- LoZ: Low input impedance mode helps to avoid false readings caused by ghost voltages, providing more reliable measurements.

Figure 5.5: Advanced Measurement Functions (VFD and LoZ)
This image illustrates the application of advanced functions like VFD for motor drive measurements and LoZ for reducing interference, showcasing the meter's versatility.
5.3 Guida video operativa
For a visual demonstration of the KAIWEETS HT208F's features and operation, please refer to the official product video below:
Video 5.1: KAIWEETS Inrush Digital Clamp Meter with Backlit
Questo video fornisce una panoramica completaview and demonstration of the KAIWEETS HT208F Digital Clamp Misuratore, mostraasing its various measurement capabilities including Inrush current, continuity, diode, resistance, capacitance, AC voltage, AC current, NCV, DC voltage, and temperature measurement.
6. Manutenzione
6.1 Pulizia del dispositivo
Per garantire la longevità e la precisione del tuo clamp metro:
- Pulisci il contatore casing con annuncioamp panno e detersivo delicato. Non utilizzare abrasivi o solventi.
- Keep the input jacks and display clean and free of dust.
6.2 Sostituzione della batteria
Replace the batteries as described in Section 4.1 when the low battery indicator appears on the display. Prompt battery replacement ensures continued accurate operation.
6.3 Conservazione
When not in use for extended periods, store the meter in a dry, cool environment, away from direct sunlight and extreme temperatures. If storing for a long time, it is recommended to remove the batteries to prevent leakage.
7. Risoluzione Dei Problemi
If you encounter issues with your KAIWEETS HT208F, refer to the following common troubleshooting steps:
- Nessun display/misuratore non acceso: Controllare l'installazione delle batterie e assicurarsi che non siano scariche. Sostituirle se necessario.
- Letture imprecise: Ensure test leads are properly connected and not damaged. Verify the correct measurement function is selected. For DC current, ensure the REL/ZERO function has been used to zero the reading before measurement.
- Display Freezing/Glitching: Prova a spegnere e riaccendere il misuratore. Se il problema persiste, sostituisci le batterie.
- Nessun rilevamento NCV: Ensure the NCV function is selected and the sensor is positioned correctly near the live conductor.
For persistent issues or specific error codes not covered here, please contact KAIWEETS customer service.
8. Specifiche
| Caratteristica | Specificazione |
|---|---|
| Numero di modello | XSC-US-HT208F |
| Dimensioni del prodotto | 11.22 x 2.44 x 5.39 pollici |
| Peso | 1.72 libbre |
| Fonte di alimentazione | Alimentato a batteria (3 batterie AAA incluse) |
| Visualizza i conteggi | 6000 Counts TRMS |
| Gamma di corrente CA/CC | Fino a 1000 Amp |
| Volume AC/DCtage Gamma | Fino a 1000V |
| Valutazione di sicurezza | IEC 61010-1, CAT IV 600V, CAT III 1000V |
| Caratteristiche speciali | Inrush Current, NCV, VFD, LoZ, Backlight, Flashlight |
| Colore | Rosso |
9. Garanzia e supporto
KAIWEETS fornisce un 36-Month product service for the HT208F Digital Clamp Meter, ensuring long-term reliability and customer satisfaction.
For any inquiries, technical assistance, or service requests, KAIWEETS offers Servizio clienti 7/24. Please refer to the contact information provided in your product packaging or visit the official KAIWEETS websito per i dettagli del supporto.