ACiQ ACiQ-48-AC

Manuale utente del sistema di condizionamento dell'aria centrale ACiQ da 4 tonnellate e 15.5 SEER2

Model: ACiQ-48-AC / ACIQ-60-ACL / IKIC51

1. Introduzione

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your ACiQ 4 Ton 15.5 SEER2 High Efficiency Central Air Conditioner System. Please read this manual thoroughly before installation and use, and retain it for future reference. Proper installation and maintenance are crucial for optimal performance and longevity of the unit.

2. Informazioni sulla sicurezza

Istruzioni importanti per la sicurezza:

3. Prodotto finitoview e Caratteristiche

The ACiQ 4 Ton 15.5 SEER2 Central Air Conditioner System is designed for high-efficiency cooling, featuring inverter technology for precise temperature control and energy savings. This system includes an outdoor condenser, an indoor multi-positional evaporator cased coil, and a comprehensive installation kit.

Caratteristiche principali:

Componenti inclusi:

The complete system includes the following components:

ACiQ 4 Ton Central Air Conditioner System components

Figura 3.1: Sopraview of the ACiQ 4 Ton Central Air Conditioner System, showing the outdoor condenser, indoor evaporator coil, smart thermostat, and various installation kit components.

ACiQ Split System Installation Kit components

Figura 3.2: Dettagliato view of the ACiQ Split System Installation Kit, including the insulated line set, electrical whip, disconnect switch, surge protector, and smart thermostat.

ACiQ Air Conditioner Condenser Unit Features

Figura 3.3: Close-up of the ACiQ outdoor condenser unit, highlighting its robust construction and fan design.

4. Configurazione e installazione

Installazione professionale richiesta: Due to the complexity of HVAC systems, installation and initial setup of this ACiQ unit must be performed by a certified and qualified HVAC technician. Attempting to install the system without proper training and tools can lead to property damage, personal injury, and void the product warranty.

Il processo di installazione in genere prevede:

  1. Selezione del sito: Choosing appropriate locations for the outdoor condenser and indoor evaporator coil, ensuring adequate airflow and drainage.
  2. Mounting Units: Securely mounting the outdoor condenser (using the provided wall mount bracket if applicable) and positioning the indoor evaporator coil.
  3. Collegamento della linea del refrigerante: Connecting the insulated line set between the indoor and outdoor units, ensuring proper brazing and leak testing.
  4. Cavi elettrici: Connecting the electrical whip, disconnect switch, and surge protector according to local electrical codes and the unit's wiring diagram.
  5. Drenaggio della condensa: Installing proper drainage for the indoor evaporator coil.
  6. Vacuum and Charging: Evacuating the refrigerant lines and charging the system with the correct amount of R410A refrigerant.
  7. Installazione del termostato: Wiring and configuring the Smart WiFi Thermostat.
  8. Prova di sistema: Performing a comprehensive test run to ensure all components are functioning correctly and efficiently.

Refer to the detailed installation guide provided to your HVAC technician for specific instructions and diagrams.

5. Istruzioni per l'uso

Your ACiQ system is controlled by the included Smart WiFi Thermostat. Once installed and configured by a professional, operating the system is straightforward.

Smart WiFi Thermostat Operation:

The thermostat allows you to control various aspects of your air conditioning system. Consult the separate thermostat user manual for detailed instructions on its specific features, including:

Smart WiFi Thermostat features and interface

Figura 5.1: Diagram illustrating the features and interface of the Smart WiFi Thermostat, including mode, humidity, temperature settings, and connectivity options.

For optimal performance, set the thermostat to a comfortable temperature and avoid frequent, drastic changes. The inverter technology will maintain the set temperature efficiently.

6. Manutenzione

Regular maintenance is essential to ensure the longevity, efficiency, and optimal performance of your ACiQ air conditioning system. Some maintenance tasks can be performed by the homeowner, while others require a qualified technician.

Manutenzione utente (mensile/trimestrale):

Manutenzione professionale (annuale):

It is highly recommended to schedule annual maintenance with a qualified HVAC technician. This typically includes:

7. Risoluzione Dei Problemi

Prima di contattare un tecnico dell'assistenza, rifview the following common issues and their potential solutions. For complex problems, always consult a qualified HVAC professional.

ProblemaPossibile causaSoluzione
System Not Cooling
  • Termostato impostato in modo errato
  • Filtro dell'aria sporco
  • Outdoor unit obstructed
  • Problema di alimentazione
  • Refrigerant leak (system alert)
  • Check thermostat settings (mode, temperature).
  • Pulire o sostituire il filtro dell'aria.
  • Clear debris from outdoor unit.
  • Check circuit breaker; ensure disconnect switch is ON.
  • Contattare un tecnico qualificato per l'ispezione e la riparazione.
Flusso d'aria debole
  • Filtro dell'aria sporco
  • Prese d'aria di ritorno bloccate
  • Problemi di condotti
  • Pulire o sostituire il filtro dell'aria.
  • Ensure all return air vents are open and unobstructed.
  • Consult a technician to inspect ductwork.
Rumori insoliti
  • Parti sciolte
  • Detriti nel ventilatore
  • Problemi al motore
  • Turn off unit and inspect for loose panels or debris.
  • If noise persists or is severe, contact a technician.
Water Leakage (Indoor Unit)
  • Clogged condensate drain line
  • Frozen evaporator coil
  • Clear the condensate drain line.
  • Turn off cooling and allow coil to defrost; check airflow and refrigerant levels. Contact technician if problem persists.

If the problem persists after attempting these solutions, or if you encounter any other issues, contact a qualified HVAC service technician.

8. Specifiche

Detailed technical specifications for the ACiQ 4 Ton 15.5 SEER2 Central Air Conditioner System:

SpecificazioneValore
MarcaACiQ
Numeri di modelloACiQ-48-AC / ACIQ-60-ACL / IKIC51
Capacità4 tonnellate (48,000 BTU/h)
Efficienza (SEER2)15.5 VEGGENTE2
Tipo di refrigeranteR410A
Voltage230 Volt
Cosatage4000 watt
Livello di rumore56 dB
Dimensioni dell'unità esterna (P x L x A)16.14" x 37.24" x 52.48"
Indoor Coil Dimensions (W x D x H)24.49" x 20.98" x 27.99" (622 x 533 x 711 mm)
Tipo di installazioneSistema diviso
Fattore di formaSistema Split Centrale
Tipo di filtroWashable, Reusable Mesh Filter
Copertura dell'area del pavimentoCirca 2400 piedi quadrati
Caratteristiche specialiUnità inverter, sensori intelligenti, serpentina con alette dorate, ultra silenziosa, prestazioni adatte a tutti i climi
Dimensions of ACiQ outdoor condenser and indoor evaporator coil

Figura 8.1: Dimensional measurements for the ACiQ outdoor condenser unit and the indoor evaporator coil.

Specifications for ACiQ evaporator coil

Figura 8.2: Detailed specifications for the ACiQ evaporator coil, including air flow, pressure, dehumidification, and dimensions.

AHRI Rating Conditions and EnergyGuide label for ACiQ system

Figura 8.3: AHRI (Air-Conditioning, Heating, and Refrigeration Institute) certification details and EnergyGuide label, confirming the system's efficiency rating.

9. Garanzia e supporto

Termini di garanzia: Il sistema ACiQ è dotato di un Garanzia sulle parti di 7 anni e un 12 anni di garanzia sul compressore. This warranty is valid when the unit is installed by a qualified technician and registered online with the manufacturer. Please ensure your installer registers the product to activate the full warranty coverage.

Assistenza clienti: For technical assistance, warranty claims, or to locate a certified service provider, please refer to the contact information provided on the ACiQ official websito o la documentazione inclusa con l'acquisto. Puoi anche visitare il Negozio ACiQ su Amazon per ulteriori informazioni.