Dr Trust NECWZ_IGH00014

Dr Trust USA Compressor Nebulizer Machine

Model: NECWZ_IGH00014 User Manual

1. Introduzione

The Dr Trust USA Compressor Nebulizer Machine, Model NECWZ_IGH00014, is designed to assist in the effective delivery of respiratory medications. This device converts liquid medication into a fine aerosol mist, allowing for deep inhalation into the lungs. It is suitable for both adults and children and is intended for use under medical supervision for conditions such as asthma, bronchitis, and other respiratory ailments. This manual provides essential information for the safe and proper operation, maintenance, and care of your nebulizer.

2. Informazioni importanti sulla sicurezza

3. Contenuto della confezione

Your Dr Trust Compressor Nebulizer Machine package includes the following components:

4. Componenti del prodotto e oltreview

Familiarize yourself with the various parts of your nebulizer system before operation.

Dr Trust Compressor Nebulizer Machine with air tube, medicine chamber, and mouthpiece

Figura 4.1: Main Nebulizer Unit with connected accessories. This image shows the compact white compressor unit, the clear air tube, and the medicine chamber with a mouthpiece attachment. The medicine chamber features a rotating top for flow adjustment.

Close-up of nebulizer medicine chamber with flow adjustment settings and diagram of particle size distribution in respiratory tract

Figura 4.2: Personalized Flow Adjustment and Particle Size. This image illustrates how to adjust the mist flow (Open/Large, Half Close/Medium, Close/No Mist) on the medicine chamber. It also shows a diagram indicating where different particle sizes (10-15 µm, 5-10 µm, 2-5 µm) are deposited in the upper, middle, and lower respiratory tracts.

5. Installazione e assemblaggio

Follow these steps to assemble your nebulizer before first use or after cleaning.

  1. Place the compressor unit on a stable, flat surface.
  2. Assicurarsi che l'interruttore di alimentazione sia in posizione "OFF".
  3. Connect one end of the air tube to the air outlet on the compressor unit.
  4. Open the medicine chamber and pour the prescribed amount of medication into it. Do not overfill.
  5. Securely close the medicine chamber.
  6. Connect the other end of the air tube to the bottom of the medicine chamber.
  7. Attach either the mouthpiece or the appropriate mask (adult or child) to the top of the medicine chamber.
Diagram showing steps for nebulizer use: placing medicine, attaching mask, connecting tube, inhaling, and turning off

Figura 5.1: Nebulizer Assembly and Usage Steps. This image visually guides through the process: 1. Placing medicine into the chamber. 2. Attaching the mask to the chamber. 3. Connecting the air tube to the device. These steps are crucial for proper setup.

6. Istruzioni per l'uso

Once assembled, follow these steps to begin your nebulizer treatment:

  1. Collegare il cavo di alimentazione a una presa elettrica idonea.
  2. Turn on the nebulizer by pressing the power switch. The compressor will start, and mist will begin to generate from the medicine chamber.
  3. Place the mouthpiece in your mouth, sealing your lips around it, or position the mask snugly over your nose and mouth.
  4. Breathe normally and deeply through the mouthpiece or mask until all the medication has been nebulized. This usually takes 5-15 minutes, depending on the medication volume and flow rate.
  5. You can adjust the mist flow rate using the adjuster on the medicine chamber (refer to Figure 4.2).
  6. Once the medication is fully dispensed and misting stops, turn off the nebulizer by pressing the power switch.
  7. Scollegare il dispositivo dalla presa di corrente.

Nota: Always consult your doctor or pharmacist for specific instructions regarding your medication and treatment duration.

7. Pulizia e manutenzione

Regular cleaning and maintenance are essential for the hygienic and effective operation of your nebulizer.

Dopo ogni utilizzo:

  1. Disconnect the air tube, medicine chamber, mouthpiece/mask from the compressor unit.
  2. Discard any remaining medication in the chamber.
  3. Wash the medicine chamber, mouthpiece, and mask with warm tap water and a mild detergent.
  4. Risciacquare abbondantemente con acqua pulita.
  5. Air dry the components completely on a clean paper towel or cloth.

Daily/Weekly Cleaning (Disinfection):

  1. After daily cleaning, disinfect the medicine chamber, mouthpiece, and mask by soaking them in a solution of one part white vinegar to two parts distilled water for 30 minutes, or use a commercially available nebulizer disinfectant.
  2. Rinse thoroughly with sterile water and air dry.

Unità compressore:

Sostituzione del filtro dell'aria:

8. Risoluzione Dei Problemi

ProblemaPossibile causaSoluzione
Nessun poterePower cord unplugged; power switch off; no power at outlet.Ensure power cord is securely plugged in; turn power switch ON; check outlet with another appliance.
Nessuna nebbia o pochissima nebbiaMedicine chamber empty; air tube kinked or disconnected; air filter clogged; medicine chamber clogged.Add medication; check air tube for kinks and secure connections; replace air filter; clean medicine chamber thoroughly.
Rumore forte durante il funzionamentoDevice not on a flat surface; air filter clogged.Place device on a stable, flat surface; replace air filter.

If you experience issues not listed here or if problems persist, please contact Dr Trust customer support.

9. Specifiche

10. Garanzia e supporto

The Dr Trust USA Compressor Nebulizer Machine comes with a Garanzia di 2 anno dalla data di acquisto. Conservare la ricevuta d'acquisto per eventuali reclami in garanzia.

For technical support, service, or warranty inquiries, please contact Dr Trust customer service. Contact information can typically be found on the Dr Trust official websito o sulla confezione del prodotto.

You can visit the official Dr Trust store for more information: Dr Trust Store on Amazon

Documenti correlati - NECWZ_IGH00014

Preview Dr Trust Bestest Compressor Nebulizer 401 User Manual
Comprehensive user manual for the Dr Trust Bestest Compressor Nebulizer 401, providing instructions for setup, operation, cleaning, and troubleshooting for effective respiratory therapy.
Preview Manuale utente del nebulizzatore portatile a rete Dr Trust 404
Questo manuale utente fornisce istruzioni dettagliate per il funzionamento, la pulizia e la manutenzione del nebulizzatore portatile a rete Dr Trust 404, comprese precauzioni di sicurezza, risoluzione dei problemi e specifiche.
Preview Nebulizzatore a compressore Dr Trust 407 con regolatore di flusso - Manuale utente e guida
Manuale utente completo e guida per il nebulizzatore a compressore Dr Trust 407 con regolatore di flusso. Scopri di più sul prodottoview, operating instructions, cleaning, specifications, and customer support for this respiratory therapy device.
Preview Manuale d'uso del nebulizzatore a compressore Dr Trust 407 con regolatore di flusso
Manuale utente completo per il nebulizzatore a compressore Dr Trust 407 con regolatore di flusso, che descrive in dettaglio le sue caratteristiche, il funzionamento, la pulizia e le precauzioni di sicurezza per una terapia respiratoria efficace.
Preview Dr Trust Anti Decubitus Air Mattress Bubble 301 User Manual
User manual for the Dr Trust Anti Decubitus Air Mattress Bubble 301, detailing its introduction, principle of operation, guidelines for use, main components, setup, operation, maintenance, and specifications.
Preview Misuratore di pressione sanguigna Dr Trust Goldline con MDI - Manuale utente
Manuale utente per il misuratore di pressione sanguigna Dr Trust Goldline con MDI, che descrive dettagliatamente configurazione, funzionamento, caratteristiche come la tecnologia MDI e l'uscita vocale in hindi/inglese, linee guida di sicurezza e specifiche tecniche per un monitoraggio accurato della pressione sanguigna.