1. Informazioni sulla sicurezza
Before using the ZIBOO 15B PRO Digital Multimeter, please read and understand all safety instructions. Failure to follow these instructions may result in electric shock, fire, or personal injury.
1.1 Linee guida generali sulla sicurezza
- Prima di effettuare le misurazioni, assicurarsi sempre che il multimetro sia impostato sulla funzione e sull'intervallo corretti.
- Non utilizzare il multimetro se appare danneggiato o se i puntali di prova sono compromessi.
- Observe all safety precautions for working with electricity, including wearing appropriate personal protective equipment (PPE).
- Never exceed the maximum input values for any function.
- The device is rated CAT III 600V and CAT II 1000V. Adhere to these ratings for safe operation.
- The multimeter features double fuse protection to prevent damage from overload.
2. Prodotto finitoview
The ZIBOO 15B PRO True RMS Digital Multimeter is a compact and reliable tool designed for a wide range of electrical testing applications. It offers accurate measurements for AC/DC voltage, AC/DC current, resistance, continuity, diode, capacitance, and duty cycle. Its True RMS capability ensures precise readings for non-sinusoidal waveforms.

Figura 1: Fronte view of the ZIBOO 15B PRO Digital Multimeter, showing the display, rotary dial, and function buttons.
2.1 Caratteristiche principali
- Vero valore efficace: Provides accurate measurements for both sinusoidal and non-sinusoidal AC waveforms.
- Visualizzazione di 6000 conteggi: Display ad alta risoluzione per letture precise.
- Volume AC/DCtage: Measures up to 1000V.
- Corrente CA/CC: Measures up to 10A (optional current clamp for up to 600A).
- Resistance, Continuity, Diode, Capacitance, Duty Cycle: Essential functions for comprehensive electrical troubleshooting.
- VFD AC 600V: Variable Frequency Drive measurement capability.
- NCV/LIVE: Volume senza contattotage and Live Wire Detection with Red LED Flash.
- Data Hold: Blocca la lettura visualizzata per facilitarne la registrazione.
- Retroilluminazione: Bright white backlight for clear visibility in various lighting conditions.
- Protettivo Casing: Esterno durevole casing per una maggiore protezione.

Figure 2: Visual representation of the various measurement functions available on the multimeter.
2.2 Cosa c'è nella scatola
- ZIBOO 15B PRO Digital Multimeter
- Cavi di prova per multimetro (rosso e nero)
- Protective Caps for Test Leads
- Manuale d'uso
Note: AC pliers are an optional accessory and are not included with the standard package.
3. Impostazione
3.1 Installazione della batteria
- Assicurarsi che il multimetro sia spento.
- Individuare il vano batteria sul retro del dispositivo.
- Unscrew the single Phillips #1 screw to open the compartment.
- Insert three AA 1.5V batteries, observing correct polarity.
- Riposizionare il coperchio del vano batteria e fissarlo con la vite.
3.2 Collegamento dei puntali di prova
- Inserire il puntale di prova nero nel jack 'COM' (comune).
- Per la maggior parte delle misurazioni (voltage, resistance, continuity, diode, capacitance, frequency, duty cycle), insert the red test lead into the 'VΩHz' jack.
- Per misurazioni di corrente fino a 10 A, inserire il puntale di prova rosso nel jack '10 A'.
- Per milliampere (mA) o microampere (µA) measurements, insert the red test lead into the 'µAmA' jack.

Figure 3: The ZIBOO 15B PRO Multimeter with its test leads, showing the connection points.
4. Istruzioni per l'uso
4.1 Accensione/spegnimento e display
Turn the rotary dial from 'OFF' to any desired function to power on the multimeter. To power off, turn the dial back to 'OFF'. The device features an automatic power-off function to conserve battery life. Press the GUIDATO button to activate or deactivate the display backlight for improved visibility.
4.2 Funzioni di misura
Rotate the dial to select the desired measurement function. Use the MODALITÀ button to toggle between different sub-functions within a dial position (e.g., AC/DC voltage, NCV/LIVE).
- Voltage Misurazione (AC/DC):
Set the dial to 'V~' for AC voltage o 'V=' per DC voltage. Connect the test leads in parallel to the circuit or component being measured. The display will show the voltage lettura. - Misurazione della corrente (CA/CC):
Set the dial to 'A~' for AC current or 'A=' for DC current. Ensure the red test lead is in the appropriate current jack (10A or µAmA). Connect the multimeter in series with the circuit. - Misurazione della resistenza (Ω):
Set the dial to 'Ω'. Connect the test leads across the component. Ensure the circuit is de-energized before measuring resistance. - Prova di continuità (
):
Set the dial to 'Ω' and press MODALITÀ until the continuity icon appears. A buzzer will sound and a green LED will flash if continuity is detected (low resistance). - Prova diodi (
):
Set the dial to 'Ω' and press MODALITÀ until the diode icon appears. Connect the test leads across the diode. - Misurazione della capacità (F):
Set the dial to 'F'. Connect the test leads across the capacitor. Ensure the capacitor is discharged before measurement. - NCV (Volume senza contattotage) / LIVE (Live Wire Detection):
Set the dial to 'NCV LIVE'. The multimeter will detect AC voltage without direct contact. 'L' indicates a live wire with voltage, accompanied by a red LED flash and buzzer. 'EF' indicates non-contact detection.

Figure 4: The multimeter's NCV function detecting voltage near an electrical outlet, indicated by 'EF' on the display.
Video 1: This video demonstrates the difference between the NCV (Non-Contact Voltage) and LIVE (Live Wire Detection) functions on the ZIBOO 15B PRO/17B PRO multimeters. It shows how to toggle between these modes and their respective indications when detecting live electrical circuits.
4.3 Funzioni speciali
- TENERE: Premere il tasto PRESA pulsante per congelare la lettura corrente sul display. Premere di nuovo per rilasciare.
- MINIMO MASSIMO: Premere il tasto MINIMO MASSIMO button to record the minimum and maximum values during a measurement session. Press again to cycle through MIN, MAX, and current readings.
- RANGE: Premere il tasto Consumo button to switch between auto-ranging and manual ranging.
5. Manutenzione
5.1 Pulizia
Pulisci il multimetro casing con annuncioamp panno e detergente delicato. Non utilizzare detergenti abrasivi o solventi. Assicurarsi che il dispositivo sia completamente asciutto prima dell'uso.
5.2 Sostituzione della batteria
When the battery indicator appears on the display, replace the batteries as described in Section 3.1. Always use three new AA 1.5V batteries.
5.3 Sostituzione del fusibile
The multimeter is equipped with internal fuses for protection. If a current measurement function stops working, the fuse may need replacement. To access the fuses, open the battery compartment (Section 3.1). The fuses are located inside. Replace with fuses of the correct type and rating (e.g., 10A/1000V and 500mA/1000V).

Figura 5: Interno view highlighting the double fuse protection for safety and durability.
5.4 Cura del puntale di prova
The test leads come with protective caps. Use these caps to protect the sharp tips when not in use or when measuring in situations where only a short tip is required. This helps prevent damage to the probes and ensures safety.
6. Risoluzione Dei Problemi
If you encounter issues with your ZIBOO 15B PRO Digital Multimeter, refer to the following common troubleshooting steps:
- Nessun display/Display debole: Check battery levels and replace if necessary. Ensure the multimeter is powered on.
- Letture errate: Verify the test leads are correctly inserted into the appropriate jacks for the selected function. Ensure the rotary dial is set to the correct measurement type and range. Check for damaged test leads.
- Current Function Not Working: The internal fuse for current measurement may have blown due to an overload. Replace the fuse as described in Section 5.3.
- Il cicalino di continuità non suona: Ensure the multimeter is in continuity mode. Check for open circuits or high resistance.
For persistent issues, consult the manufacturer's support resources.
7. Specifiche
| Caratteristica | Specificazione |
|---|---|
| Display | 6000 conteggi, vero RMS |
| Volume DCtage(V) | 6V/60V/600V/1000V (±(0.5%+3)) |
| Volume ACtage(V) | 6V/60V/600V/1000V (±(0.8%+5)) |
| Vol. CA VFDtage(V) | 600 V (±(0.8%+5)) |
| Corrente CC (A) | 600µA/6mA/60mA/600mA/6A/10A (±(0.8%+5) to ±(1.5%+5)) |
| Corrente AC (A) | 600µA/6mA/60mA/600mA/6A/10A (±(1.0%+5) to ±(1.8%+5)) |
| Resistenza (Ω) | 600Ω/6KΩ/60KΩ/600KΩ/6MΩ/60MΩ (±(0.8%+5) to ±(2.5%+5)) |
| Capacità (F) | 60nF-60mF (±(3%+5) to ±(5%+5)) |
| Frequenza (Hz) | 10Hz-20MHz (±(0.1%+5)) |
| Ciclo di lavoro | 10%-90% (±(2%+5)) |
| Valutazione di sicurezza | CAT III 600 V, CAT II 1000 V |
| Fonte di alimentazione | 3 batterie AA da 1.5 V |
| Dimensioni del prodotto | 3.58 x 1.77 x 7.2 pollici |
| Peso del prodotto | 1.19 libbre (402 g) |
Note: Accuracy specifications are typical values and may vary slightly.

Figure 6: A detailed table outlining the technical specifications for the ZIBOO 15B PRO multimeter.
8. Garanzia e supporto
For warranty information and customer support, please refer to the official ZIBOO website or contact the seller directly through the platform where the product was purchased. Standard return policies typically apply (e.g., 30-day return window).