GODIYMODULES Mod-CR12V-001

GODIYMODULES DC 12V 0.1s-99h Multifunction Digital Time Delay Relay User Manual

Model: Mod-CR12V-001

1. Introduzione

This manual provides detailed instructions for the installation, operation, and configuration of the GODIYMODULES DC 12V 0.1s-99h Multifunction Digital Time Delay Relay. This versatile module offers precise timing control for various applications, featuring multiple operating modes and a wide time delay range.

2. Caratteristiche principali

  • Multi-function relay module with 8 distinct operating modes.
  • Adjustable time delay range from 0.1 seconds to 99 hours.
  • Digital display for clear time and mode indication.
  • Operates on DC 12V power supply.
  • Integrated smart relay switch functionality.

3. Specifiche

Numero di modelloMod-CR12V-001
Ingresso volumetageCC 12V
Intervallo di tempo0.1 secondi a 99 ore
Valutazione contatto relè10A 250VAC / 10A 125VAC / 10A 30VDC / 10A 28VDC
DimensioniCirca 3 x 1.5 x 0.48 pollici
PesoCirca 0.96 once

4. Prodotto finitoview

The time delay relay module features a compact design with clearly labeled terminals and control buttons. It includes a digital display for time and mode settings, a relay, and input/output terminals.

GODIYMODULES Time Delay Relay Module with labeled components

Figura 4.1: Davanti view of the time delay relay module with key components labeled. This image shows the digital display, control buttons (SET, ADD, Enter), input terminals (IN, GND, VCC), and relay output terminals (NC, COM, NO).

Indietro view of the GODIYMODULES Time Delay Relay Module

Figura 4.2: Indietro view of the time delay relay module, showing the solder points and circuit board layout.

5. Configurazione e cablaggio

Proper wiring is essential for the safe and correct operation of the module. Ensure all connections are secure before applying power.

5.1. Common Wiring Diagram (Shared DC Power Supply)

This diagram illustrates how to connect the module and an equipment load when both share a common DC power supply.

Wiring diagram for DC 12V time delay relay with shared power supply

Figura 5.1: Wiring diagram showing the module connected to a DC power supply and an equipment load. DC+ and DC- from the power supply connect to the module's VCC and GND terminals, respectively. The trigger input is connected to the IN terminal. The equipment is connected to the relay's COM and NO (Normally Open) terminals, with the other side of the equipment connected to DC+.

5.2. Module Control AC Load Wiring Diagram

This diagram shows how to use the module to control an AC load, such as a 220V device. Note that the module itself is powered by DC 12V, but its relay can switch AC power.

Wiring diagram for DC 12V time delay relay controlling an AC load

Figura 5.2: Wiring diagram for controlling an AC load. The module is powered by DC 12V (DC+ to VCC, DC- to GND). The trigger input connects to IN. The AC load (e.g., 220V equipment) is connected to the relay's COM and NO terminals, with the AC "Fire Wire" connected to one relay terminal and the "Zero Wire" connected to the other side of the equipment.

6. Operating Instructions and Modes

The module offers 8 distinct operating modes, adjustable from 0.1 seconds to 99 hours. Use the control buttons (SET, ADD, Enter) to configure the desired mode and time parameters.

6.1. Setting Time Unit

To select the T1 time unit, press the AGGIUNGERE button. The display will show a value (0/1/2/3). Press AGGIUNGERE again to cycle between the units:

  • 0: Seconds (0.1s - 99.9s)
  • 1: Seconds (1s - 999s)
  • 2: Minutes (1min - 999min)
  • 3: Hours (1h - 99h)

6.2. Selezione della modalità operativa

Premere e tenere premuto il tasto IMPOSTATO button for a long time to enter the function selection menu. The display will show P1-P8. Press the IMPOSTATO button briefly to switch between the 8 functions.

6.3. Detailed Mode Descriptions

Detailed descriptions of the 8 operating modes for the time delay relay

Figura 6.1: Visual representation of the 8 operating modes (P-1 to P-8) with their respective descriptions and functionalities.

  1. P-1: Delayed Disconnection
    The relay is activated upon power-on. After a delay of T1, the relay disconnects.
  2. P-2: Time-Delayed Absorption (Triggered)
    Upon power-on, the time delay T1 starts. After T1, the relay engages. A low-level signal on the IN terminal will re-trigger this function once.
  3. P-3: Cyclic On/Off (Power-on Start)
    Upon power-on, the relay engages. After delay T1, the relay disconnects. After delay T2, the relay engages. This cycle repeats. The number of cycles can be adjusted from 1 to 99 or set for an infinite cycle.
  4. P-4: Cyclic On-Off (Delay First, Power-on Start)
    Upon power-on, delay T1 starts. After T1, the relay engages. After delay T2, the relay disconnects. This cycle repeats. The number of cycles can be adjusted from 1 to 99 or set for an infinite cycle.
  5. P-5: Trigger Delay Absorption (Repeatable)
    The relay is initially inactive. After a trigger signal, the relay activates. After delay T1, the relay disconnects. A low-level signal on the IN terminal will re-trigger this function. The cycle times can be adjusted from 1 to 99 or set for an infinite cycle.
  6. P-6: Trigger Time-Delay Disconnect
    The relay is initially inactive. Upon triggering, the relay engages. After delay T1, the relay disconnects. A low-level signal on the IN terminal will re-trigger this function once.
  7. P-7: Trigger Cycle On-Off (Repeatable)
    The relay is initially inactive. Upon triggering, the relay engages. After delay T1, it disconnects. After delay T2, it engages. This cycle repeats. The number of cycles can be adjusted from 1 to 99 or set for an infinite cycle.
  8. P-8: Trigger Cycle On/Off (Delayed Start)
    The relay is initially inactive. Upon triggering, delay T1 starts. After T1, the relay engages. After delay T2, the relay disconnects. This cycle repeats. The number of cycles can be adjusted from 1 to 99 or set for an infinite cycle.

7. Manutenzione

The GODIYMODULES Time Delay Relay is designed for reliable operation with minimal maintenance. To ensure longevity and proper function:

  • Mantenere il modulo pulito, privo di polvere e umidità.
  • Evitare di esporre il modulo a temperature estreme o alla luce solare diretta.
  • Controllare periodicamente tutti i collegamenti elettrici per accertarsi che siano sempre saldi.
  • Do not attempt to open or modify the module, as this may void any warranty and could lead to malfunction.

8. Risoluzione Dei Problemi

If you encounter issues with your time delay relay module, consider the following common troubleshooting steps:

  • Il modulo non si accende: Verify that the DC 12V power supply is correctly connected to the VCC and GND terminals and is providing the correct voltage. Check for loose connections or damaged wires.
  • Relè non attivato/disattivato:
    • Ensure the correct operating mode (P-1 to P-8) is selected.
    • Check the set time (T1, T2) and time unit.
    • If using a trigger, verify the trigger signal is being applied correctly to the IN terminal.
    • Confirm the load is correctly wired to the relay's COM, NO, or NC terminals.
  • Tempismo errato: Double-check the set time values and the selected time unit (seconds, minutes, hours).
  • Problemi di visualizzazione: If the digital display is blank or showing erratic characters, check the power supply and connections.

Se i problemi persistono, contatta l'assistenza clienti per ulteriore assistenza.

9. Garanzia e supporto

For warranty information and technical support, please refer to the product packaging or contact GODIYMODULES customer service directly. Keep your purchase receipt as proof of purchase.

Documenti correlati - Mod-CR12V-001

Preview Come iniziare a usare il tuo MOD Timer: Guida per l'utente
Scopri come configurare e utilizzare il tuo MOD Time Timer. Questa guida riguarda l'installazione della batteria, le preferenze audio, le impostazioni del timer e la manutenzione del tuo timer visivo.
Preview Time Timer MOD: Getting Started Guide and User Manual
Learn how to set up and use your Time Timer MOD with this comprehensive getting started guide. Covers battery installation, sound preferences, timer setting, battery care, and product maintenance. Includes information on GE Lighting CYNC smart home devices.
Preview Manuale d'uso dei moduli di apparecchiatura Luminor Blackcomb: funzionamento e installazione
Questo manuale del proprietario fornisce istruzioni dettagliate per l'uso e l'installazione dei moduli delle apparecchiature Luminor Blackcomb, tra cui l'emulatore (MOD-EMU), l'allarme remoto (MOD-RAM), 4-20 mA (MOD-420), il solenoide (MOD-SOL), il monitor della qualità dell'acqua SHERPA (MOD-SHERPA) e il concierge UV (MOD-APP).
Preview Walrus Audio Mako D1 MKII High-Fidelity Stereo Delay Pedal User Manual
Comprehensive guide to the Walrus Audio Mako D1 MKII, a feature-packed, high-fidelity all-in-one stereo delay pedal with six distinct algorithms, controls, presets, and MIDI integration.
Preview Manuale utente del modellatore di ritardo Line 6 DL4
Manuale utente completo per Line 6 DL4 Delay Modeler, che descrive in dettaglio le sue caratteristiche, funzioni e funzionamento, inclusi vari modelli di delay, loopampler e opzioni di connettività.
Preview Smappee Infinity Installationshandbuch: Leitfaden zur Installation und Konfiguration des Energiemanagementsystems
Dieses Installationshandbuch bietet detaillierte Anleitungen zur physischen Installation, Konfiguration und Validierung des Smappee Infinity Energiemanagementsystems, das Echtzeit-Energieüberwachung, IoT-Steuerung und Lastausgleich ermöglicht. Für zertifizierte Installateure.