Introduzione
This manual provides detailed instructions for the setup, operation, and maintenance of your AMIR Wireless Indoor Outdoor Thermometer with 3 Remote Sensors. This device is designed to monitor temperature and humidity in various indoor and outdoor environments, providing accurate data for your home, office, or other spaces.
Cosa c'è nella scatola
- 1 x Main Display Unit (Thermometer)
- 3 sensori remoti wireless
- 1 x Manuale di istruzioni
Nota: 3 AAA batteries are required for the main unit and 2 AAA batteries for each sensor (not included).
Prodotto finitoview
The AMIR Wireless Indoor Outdoor Thermometer system consists of a main display unit and three remote sensors. The main unit displays indoor temperature and humidity, along with readings from the three remote sensors. The remote sensors transmit data wirelessly to the main unit.
Unità di visualizzazione principale

Image: The main display unit showing temperature and humidity readings, alongside three remote sensors.
- Ampio display LCD: Shows indoor temperature/humidity and data from up to 3 remote sensors simultaneously.
- Funzione di retroilluminazione: Per una visibilità ottimale in condizioni di scarsa illuminazione.
- Pulsanti: MIN/MAX, LIGHT, CHANNEL.
- Opzioni di montaggio: Integrated stand for tabletop use and a hang hole for wall mounting.
Sensori a distanza

Image: The main display unit and one remote sensor, illustrating their compact dimensions.
- Trasmissione senza fili: Sends temperature and humidity data to the main unit.
- Design compatto: Suitable for various placements.
- Montaggio: Hang hole for easy placement.
Impostare
1. Installazione della batteria
Ensure you have 3 AAA batteries for the main unit and 2 AAA batteries for each remote sensor (not included).
- Unità di visualizzazione principale: Open the battery compartment on the back of the main unit. Insert 3 AAA batteries, observing the correct polarity (+/-). Close the compartment.
- Sensori remoti: Open the battery compartment on the back of each remote sensor. Insert 2 AAA batteries into each sensor, observing the correct polarity (+/-). Close the compartment.

Image: Illustration of battery compartment and battery insertion for both the main unit and remote sensors.
2. Sincronizzazione iniziale
After installing batteries, the main unit will automatically search for signals from the remote sensors. This process may take a few minutes. Ensure all sensors are within range of the main unit during initial setup.
- The main unit will display indoor temperature and humidity, along with readings from the connected sensors (Channel 1, 2, 3).
- If a sensor does not connect, try pressing the "CHANNEL" button on the main unit to cycle through channels or re-insert the batteries in the sensor.
3. Posizionamento
Place the main unit and remote sensors in desired locations. The wireless transmission range is approximately 100 meters (328 feet) in open air. Walls and other obstructions may reduce this range.
- Unità principale: Can be placed on a tabletop using its integrated stand or mounted on a wall using the hang hole.
- Sensori remoti: Can be placed outdoors, in a baby room, wine cellar, greenhouse, or any other area where you wish to monitor conditions. Use the hang hole for wall mounting or place on a flat surface.

Immagine: Examples of wall-mount and tabletop placement for the main unit and a remote sensor.
Istruzioni per l'uso
1. Selezione dell'unità di temperatura (℃/℉)
Press the "℃/℉" button on the main unit to switch between Celsius and Fahrenheit temperature display.
2. Max/Min Record Function
The device records the maximum and minimum temperature and humidity values for the main unit and each sensor.
- View Massimo/minimo: In normal display mode, press the "MIN/MAX" button once to display the maximum indoor/outdoor temperature and humidity. The screen will show "MAX". Press again to display the minimum indoor/outdoor temperature and humidity. The screen will show "MIN".
- Clear Max/Min: To manually clear today's maximum/minimum values, press and hold the "MIN/MAX" button for approximately 5 seconds while viewing the MAX or MIN records.
- Ripristino automatico: The unit may also have an automatic 24-hour reset for MIN/MAX values. To switch between 24-hour reset and all-time (manual reset) modes, hold down the MIN/MAX button for ~5 seconds when the display shows current data (not MAX or MIN). A "24hr" badge will indicate the 24-hour mode.

Image: A graphical representation of how maximum and minimum temperature and humidity values are recorded.
3. Funzione di retroilluminazione
Press the "LIGHT" button on the main unit to activate the backlight. The backlight will automatically turn off after 5 seconds to conserve battery power.

Image: A close-up showing the "LIGHT" button on the main display unit.
4. Indicatore del livello di comfort
The main unit displays a smiley icon to indicate the comfort level based on humidity:
- ASCIUTTO: Umidità < 45%
- COM (Comodo): 45% ≤ Umidità ≤ 65%
- BAGNATO: Umidità > 65%

Image: Visual guide to the comfort level icons displayed on the main unit, correlating humidity percentages with "Dry," "Comfortable," and "Wet" conditions.
Manutenzione
- Pulizia: Wipe the main unit and sensors clean with a soft, damp panno. Non utilizzare detergenti abrasivi né immergere i dispositivi in acqua.
- Sostituzione della batteria: When a low battery icon appears on the main unit for a specific sensor, it indicates that the batteries in that remote sensor need to be replaced. Replace all batteries in the sensor with new AAA batteries to ensure optimal performance.
- Magazzinaggio: Se si conserva il dispositivo per un periodo prolungato, rimuovere tutte le batterie per evitare perdite.
Risoluzione dei problemi
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Nessun display sull'unità principale. | Le batterie sono scariche o installate in modo errato. | Controllare la polarità delle batterie e sostituirle con batterie AAA nuove. |
| Remote sensor not displaying data. |
|
|
| Letture imprecise. |
|
|
| MIN/MAX values not resetting as expected. | Incorrect mode selected (24hr vs. all-time). | Mentre viewing current data (not MAX/MIN), press and hold the "MIN/MAX" button for ~5 seconds to toggle between 24-hour reset and all-time modes. |
Specifiche
- Numero modello: US-WA54
- Intervallo di temperatura interna: 0℃ - 60℃ (32℉ - 140℉)
- Intervallo di temperatura esterna: -40℃ - 60℃ (-40℉ - 140℉)
- Gamma di umidità: 10% - 99% UR
- Precisione della temperatura: ±1℃ (±1.8℉)
- Precisione dell'umidità: ±5% UR
- Gamma di trasmissione wireless: 100 m / 328 piedi (all'aperto)
- Data Update Rate: Ogni 60 secondi
- Potenza dell'unità principale: 3 batterie AAA (non incluse)
- Potenza del sensore: 2 batterie AAA per sensore (non incluse)
- Tipo di visualizzazione: LCD digitale con retroilluminazione
- Materiale: Acrilonitrile Butadiene Stirene (ABS)
- Dimensioni del prodotto: Main Unit: Approximately 95mm (3.74in) Width x 78mm (3.07in) Height x 20mm (0.79in) Depth; Remote Sensor: Approximately 53mm (2.09in) Width
- Caratteristiche speciali: Fast Reading System, High Accuracy, Large Display, Low Battery Indicator, Ultra Clear Screen
Garanzia e supporto
AMIR products are designed for reliability and performance. For warranty information or technical support, please refer to the contact details provided with your product packaging or visit the official AMIR websito. Conservare la ricevuta d'acquisto per eventuali reclami in garanzia.