1. Introduzione
This manual provides instructions for the proper use and maintenance of the Dasqua 7 Piece 0-16-Inch Electronic Depth Gage Set, model 4710-1205. This electronic depth gage is designed for precise depth measurements in various industrial and scientific applications. It features a digital display for clear readings and is constructed for durability and accuracy.

Image 1.1: The Dasqua 7 Piece 0-16-Inch Electronic Depth Gage Set, showing the main unit and various measurement rods.
2. Contenuto della confezione
Verificare che tutti i componenti siano presenti nella confezione:
- Electronic Depth Gage Unit
- Set of Measurement Rods (7 pieces)
- Custodia di stoccaggio
- Lettera di garanzia

Image 2.1: The complete Dasqua Electronic Depth Gage Set, including the main unit, measurement rods, and storage case.
3. Caratteristiche principali
- Risoluzione: 0.0005-inch / 0.01mm for precise measurements.
- Conformità standard: Manufactured in accordance with DIN863 standards.
- Mandrino: Hardened, ground, and lapped for enhanced accuracy.
- Versatilità: Designed to accommodate a broad range of measurement applications.
- Display: Large, digital display for clear and quick readings.
- Costruzione: Hardened stainless steel base and rods resist wear, ensuring durability and consistent accuracy.
- Azzeramento: Ability to reset to zero at any position for comparative depth measurements.
4. Istruzioni per l'installazione
4.1. Installazione della batteria
The electronic depth gage typically uses a CR2032 lithium coin cell battery. To install or replace the battery:
- Individuare il coperchio del vano batterie sul retro dell'unità display digitale.
- Per aprire il coperchio, utilizzare un piccolo cacciavite o una moneta.
- Inserire una nuova batteria CR2032 con il lato positivo (+) rivolto verso l'alto.
- Riposizionare saldamente il coperchio del vano batteria.
4.2. Attaching Measurement Rods
Select the appropriate measurement rod for the desired depth range. The set includes rods of various lengths.
- Identify the threaded end of the measurement rod.
- Carefully screw the rod into the threaded hole at the bottom of the depth gage's base until it is finger-tight. Do not overtighten.
- Ensure the rod is securely attached and straight.

Image 4.1: The electronic depth gage with a measurement rod properly attached to its base.

Image 4.2: A selection of the hardened stainless steel measurement rods provided with the depth gage set.
5. Istruzioni per l'uso
5.1. Accensione/spegnimento
- Premere il tasto ACCESO/SPENTO pulsante per accendere il dispositivo.
- Premere il tasto ACCESO/SPENTO button again to power off the device.
5.2. Unit Conversion (Inch/Millimeter)
- Premere il tasto mm/pollice button to switch between millimeter (mm) and inch (in) units. The selected unit will be displayed on the screen.
5.3. Zero Setting
The zero-reset function allows for comparative measurements or setting a reference point.
- Place the depth gage on a flat, stable reference surface, ensuring the measurement rod is fully retracted or resting on the surface.
- Premere il tasto ZERO pulsante. Il display mostrerà '0.000' o '0.00'.
5.4. Effettuare una misurazione
- Ensure the depth gage is zeroed on a reference surface.
- Place the base of the depth gage firmly on the surface from which the depth is to be measured.
- Lower the measurement rod into the hole or recess until its tip contacts the bottom.
- Leggere la misurazione direttamente sul display digitale.
5.5. Mantieni la funzione
- Premere il tasto PRESA pulsante per congelare la lettura corrente sul display.
- Premere il tasto PRESA nuovamente il pulsante per annullare la lettura e tornare alla misurazione in tempo reale.

Immagine 5.1: Dettagliata view of the digital display, showing the ON/OFF, mm/in, HOLD, and ZERO buttons.
6. Manutenzione
6.1. Pulizia
- Wipe the depth gage and rods with a clean, dry, lint-free cloth after each use.
- Per lo sporco ostinato, utilizzare un panno leggermente dampened with isopropyl alcohol. Avoid harsh chemicals or solvents.
- Ensure no liquid enters the electronic components.
6.2. Conservazione
- Store the depth gage in its protective case when not in use.
- Keep the device in a dry environment, away from direct sunlight, extreme temperatures, and high humidity.
- Se si conserva il prodotto per un periodo prolungato, rimuovere la batteria per evitare perdite.
6.3. Sostituzione della batteria
Replace the battery when the display becomes dim or erratic. Refer to Section 4.1 for battery installation instructions.
7. Risoluzione Dei Problemi
- Il display è vuoto o poco luminoso:
Check battery installation. Replace the battery if necessary. Ensure the device is powered on. - Letture imprecise:
Ensure the depth gage is properly zeroed on a flat reference surface. Clean the measurement rod and base to remove any debris. Verify the measurement rod is securely attached. - Pulsanti non reattivi:
Check battery level. If the issue persists after battery replacement, contact customer support.
8. Specifiche del prodotto
| Specificazione | Dettaglio |
|---|---|
| Numero di modello | 4710-1205 |
| Campo di misura | 0-16 pollici / 0-400 mm |
| Risoluzione | 0.0005 pollici / 0.01 mm |
| Precisione | 0.0015 pollici / 0.03 mm |
| Materiale | Acciaio inossidabile temprato |
| Fonte di alimentazione | CR2032 Battery (typical) |
| Dimensioni del pacco | 9 x 5 x 2 pollici |
| Peso dell'articolo | 12.8 once |

Image 8.1: Detailed specifications and dimensional diagram for the Dasqua 0-16 inch Electronic Depth Gage Set.
9. Garanzia e supporto
This product is supplied with a warranty letter. For specific warranty terms and conditions, please refer to the documentation included in your package. For technical support, service, or inquiries regarding your Dasqua 4710-1205 Electronic Depth Gage Set, please contact the manufacturer directly through their official websito o canali di servizio clienti.