ATO ATO-Y2-80M2-4

ATO 1 hp (0.75kW) 3 Phase AC Induction Motor User Manual

Model: ATO-Y2-80M2-4

1. Introduzione

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your ATO 1 hp (0.75kW) 3 Phase AC Induction Motor. Please read this manual thoroughly before using the product and retain it for future reference.

The ATO 1 hp (0.75kW) 3 Phase AC Induction Motor is designed for various general-purpose machinery applications, including fans, pumps, compressors, machine tools, gearboxes, and transportation systems. It features high efficiency, robust construction, and reliable performance.

2. Prodotto finitoview

2.1 Caratteristiche principali

2.2 Componenti

The following diagram illustrates the main components of the ATO AC Induction Motor:

Diagram showing the main components of the ATO AC Induction Motor, including Rotor, Junction box, Heat Dissipation System, Copper coils, Cold-rolled silicon sheet steel, and Fixed base.

Figure 1: Motor Components Overview
This image displays the internal and external components of the motor, highlighting the rotor, junction box, heat dissipation system, copper coils, cold-rolled silicon sheet steel, and the fixed base for mounting.

3. Cosa c'è nella scatola

Dopo aver disimballato, verificare che tutti gli articoli elencati di seguito siano presenti e integri:

If any components are missing or damaged, please contact your supplier immediately.

4. Specifiche

The following table details the technical specifications of the ATO 1 hp (0.75kW) 3 Phase AC Induction Motor:

Table of technical specifications for the ATO 1 hp Induction Motor, including Model, Design Standard, Weight, Frame Type, Mounting, Wiring Method, Degree of Protection, Insulation Class, Cooling, Nominal Output, Pole Number, Nominal Speed, Frequency, Nominal Voltage, Nominal Current, Efficiency, Power Factor, Nominal Torque, Locked Rotor Torque/Nominal Torque, Maximum Torque/Nominal Torque, Locked Rotor Current/Nominal Current, Noise Level, Ambient Temperature, and Altitude.

Figura 2: Specifiche tecniche
This image presents a detailed table outlining the motor's basic, technical, and environmental parameters.

ATO 1 hp (0.75kW) Induction Motor Specifications
CategoriaParametroValore
Nozioni di baseModelloATO-Y2-80M2-4
Design StandardCEI
Peso15 kg
Tipo di telaio80 milioni
MontaggioHorizontal Foot Mounting (B3)
Metodo di cablaggioOutput≤4hp (3kW), Y connection
Output≥5.5hp (4kW), Delta connection
Parametri tecniciGrado di protezioneGrado di protezione IP54/IP55
Classe di isolamentoClasse F
RaffreddamentoTEFC (compliance to IEC 411 code of IEC 60034-6)
Potenza nominale1 hp or 0.75kW
Numero di palo4 poli
Velocità nominale1390 giri al minuto
Frequenza50 Hz
Volume Nominaletage380V (Y connection by default) / 220V (Change Y to Δ connection on your own)
Nominal Current (full load)2.05A/3.55A
Efficienza73%
Fattore di potenza (cosφ)0.76
Nominal Torque (Tn)5.15 Nm
Performance RatiosLocked Rotor Torque/Nominal Torque (IST/Tn)2.3
Maximum Torque/Nominal Torque (Tmax/Tn)2.3
Locked Rotor Current/Nominal Current (IST/In)6.0
AmbienteLivello di rumore58 dB(A)
Temperatura ambienteTemperatura di esercizio -15°C~+40°C
AltitudineAltitudineMeno di 1000 metri sul livello del mare

4.1 Dimensioni

Refer to the following diagram and table for the physical dimensions of the motor:

Diagram showing 3-phase Induction Motor Dimensions with various labeled measurements (A, B, C, D, E, F, G, H, K, AB, AC, AD, HD, L).

Figure 3: Motor Dimensions Diagram
This diagram illustrates the key mounting and overall dimensions of the motor, with labels for each measurement point.

Mounting and Overall Dimensions (mm)
Tipo di telaioMounting Dimensions (mm)Dimensioni complessive (mm)
AA/2BCDEFGHKABACADHDL
80 milioni12562.5100501940615.58010165175145220295

5. Configurazione e installazione

5.1 Precauzioni di sicurezza

5.2 Montaggio

The motor is designed for horizontal foot mounting (B3). Use the pre-drilled holes on the fixed base for secure installation. Ensure the mounting surface is stable, level, and capable of supporting the motor's weight (15kg) and operational forces.

Refer to the dimensions in Section 4.1 for precise mounting hole spacing.

5.3 collegamenti elettrici

The motor requires a 3-phase power supply. The default connection for nominal output ≤4hp (3kW) is a Star (Y) connection for 380V. For 220V operation, you may need to change to a Delta (Δ) connection. Consult a qualified electrician for wiring.

Wiring must comply with local electrical codes and regulations.

Wiring Diagrams for Three-phase squirrel-cage induction motors, showing Star (Y) Connection, Delta (Δ) Connection, and Star-Delta (Y-Δ) Connection, along with diagrams for Two Speed Motors with single and two separate windings.

Figura 4: schemi elettrici
This image provides standard wiring diagrams for three-phase squirrel-cage induction motors, including Star (Y), Delta (Δ), and Star-Delta (Y-Δ) connections, as well as configurations for two-speed motors.

6. Istruzioni per l'uso

6.1 Controlli pre-operativi

6.2 Avviamento del motore

  1. Applicare corrente al circuito del motore.
  2. Observe the motor for any unusual noises, vibrations, or overheating during the initial startup.
  3. If any abnormalities are detected, immediately shut off power and investigate the cause.

6.3 Arresto del motore

To stop the motor, simply disconnect the power supply to the motor circuit.

7. Manutenzione

Regular maintenance is crucial for ensuring the longevity and optimal performance of your ATO AC Induction Motor. Always disconnect power before performing any maintenance.

7.1 Controlli di routine (mensili)

7.2 Lubrificazione dei cuscinetti

This motor typically uses sealed bearings that are lubricated for life and do not require routine re-lubrication. If the motor exhibits unusual bearing noise, consult a qualified technician for inspection and potential bearing replacement.

7.3 collegamenti elettrici

Periodically check all electrical connections in the junction box for tightness and signs of wear or corrosion. Tighten any loose connections.

8. Risoluzione Dei Problemi

This section provides guidance for common issues. For problems not listed or if solutions do not resolve the issue, contact technical support.

Guida comune alla risoluzione dei problemi
ProblemaPossibile causaSoluzione
Il motore non si avviaNessuna alimentazione
Cablaggio non corretto
Protezione da sovraccarico scattata
Motore grippato
Controllare la fonte di alimentazione e l'interruttore automatico
Verify wiring against diagrams (Figure 4)
Reset overload protection; check for mechanical issues
Inspect for mechanical obstruction or bearing failure
Il motore si surriscaldaVentilazione insufficiente
Sovraccarico
Vol non correttotage/frequenza
Guasto del cuscinetto
Clear obstructions from cooling fins/fan
Ridurre il carico sul motore
Verify power supply matches specifications
Inspect bearings; replace if necessary
Rumore o vibrazioni eccessiviMontaggio allentato
Misalignment with driven equipment
Cuscinetti usurati
Unbalanced rotor
Serrare i bulloni di montaggio
Controllare e correggere l'allineamento
Inspect and replace bearings
Consult a specialist for rotor balancing
Il motore gira lentamente o con potenza ridottaBasso volumetage
Sovraccarico
Guasto parziale dell'avvolgimento
Controllare il volume di alimentazionetage
Ridurre il carico
Consult a qualified electrician for motor testing

9. Garanzia e supporto

For warranty information, please refer to the documentation provided at the time of purchase or contact your retailer. ATO offers technical support for its products.

Per ulteriore assistenza, visitare il sito ATO Store on Amazon oppure contatta il servizio clienti.

Documenti correlati - ATO-Y2-80M2-4

Preview Guida rapida all'installazione e all'applicazione del VFD ATO
Una guida completa per l'impostazione e l'applicazione di azionamenti a frequenza variabile (VFD) ATO, che copre l'installazione rapida, le configurazioni dei parametri e varie modalità di controllo, tra cui il controllo del pannello, il sistema a tre fili, il controllo esterno, multi-stage operation, and constant pressure water supply systems.
Preview ATO Load Cell Transmitter User Manual | ATO-LCTR-OA, ATO-LCTR-DY510
Comprehensive user manual for the ATO Load Cell Transmitter (ATO-LCTR-OA, ATO-LCTR-DY510). Learn about specifications, wiring, calibration, and features of this industrial weighing sensor and signal converter.
Preview Manuale utente della bilancia per gru digitale ATO | ATO-CRS-50T
Manuale utente completo per la bilancia digitale per gru ATO (modello ATO-CRS-50T), che illustra caratteristiche, specifiche, funzionamento, calibrazione e risoluzione dei problemi. Include dettagli sui modelli GSP911-30 e GSP911-50.
Preview Manuale utente e specifiche del misuratore di umidità ATO-TK100
Manuale utente e specifiche del misuratore di umidità digitale portatile ATO-TK100. Scopri le sue caratteristiche, il funzionamento e la manutenzione per la misurazione del contenuto di umidità in vari materiali.
Preview ATO DC Vibration Motor Speed Display Controller User Manual
User manual for the ATO DC Vibration Motor Speed Display Controller. Learn about its features, specifications, operation, and troubleshooting for variable speed control of DC brushless motors in industrial and commercial applications.
Preview Manuale operativo dello spettrofotometro a reticolo ATO
Questo manuale operativo fornisce istruzioni dettagliate per lo spettrofotometro a reticolo ATO, che riguardano la descrizione dell'interfaccia, la calibrazione, le procedure di misurazione, la gestione dei dati, le impostazioni di sistema e le specifiche tecniche per un'analisi accurata del colore.