Aiphone VM-RMVU

Manuale di istruzioni dell'unità principale di sicurezza residenziale Aiphone VM-RMVU

Model: VM-RMVU

1. Introduzione

This manual provides detailed instructions for the installation, operation, and maintenance of the Aiphone VM-RMVU Residential Fire Alarm Compatible Monitor Security Master Unit. Please read this manual thoroughly before using the product to ensure correct and safe operation. Keep this manual in a safe place for future reference.

2. Configurazione e installazione

The Aiphone VM-RMVU unit is designed for wall-mounted installation. Ensure proper power supply and network connections as described below.

2.1 Esterno View e montaggio

Refer to the diagram below for the external dimensions and mounting details. The unit requires a compatible wall box for installation.

Aiphone VM-RMVU External View and Mounting Dimensions

Immagine 1: Esterno view of the Aiphone VM-RMVU unit with detailed mounting dimensions. This diagram illustrates the physical layout, including the location of the power switch, sensors, microphone, speaker, and various indicator lights. It also shows the dimensions for wall-mounted installation.

2.2 Collegamenti di cablaggio

Follow the wiring diagram carefully to connect the master unit to power, entrance units, sub-units, and other security devices. The system supports both wired and wireless LAN connections.

Aiphone VM-RMVU Wiring Diagram

Immagine 2: Comprehensive wiring diagram for the Aiphone VM-RMVU system. This diagram details connections for power, entrance units, monitor sub-units, wireless base stations, extension master units, gas/CO alarms, auxiliary alarm devices, call buttons, security set panels, and passive sensors. It also illustrates connections for internet apps, smartphones, and Amazon Alexa devices via wireless LAN.

Alimentazione elettrica:

  • Connect the unit to an AC100V, 50/60Hz power source.
  • Ensure the power switch (located on the rear panel) is in the OFF position before connecting.

Connessione di rete:

  • The VM-RMVU supports wireless LAN (IEEE 802.11b/g/n) for connection to internet apps, smartphones, and Amazon Alexa devices.
  • Refer to the separate wireless LAN setup guide for detailed configuration instructions.

3. Istruzioni per l'uso

The Aiphone VM-RMVU features a 7-inch TFT LCD touch panel and intuitive buttons for various functions.

Aiphone VM-RMVU Front Panel Controls

Immagine 3: Front panel of the Aiphone VM-RMVU showing the 7-inch LCD display and control buttons. Key buttons include EMERGENCY, POWER indicator, TALK, OFF, OPEN, and ALARM STOP. The model name 'AIPHONE VM-RMVU' is also visible below the screen.

3.1 Funzioni di base

  • Accensione/spegnimento: Press the power switch on the rear panel to turn the unit on or off. The green POWER indicator will illuminate when on.
  • Rispondere alle chiamate: When an entrance unit calls, the display will show the caller. Press the PARLARE button to initiate a simultaneous call. The green TALK indicator will light up.
  • Chiamate finali: Premere il tasto SPENTO button to end a call. The red OFF indicator will light up briefly.
  • Apertura delle porte: Durante una chiamata, premere il tasto APRIRE button to unlock the connected door. The green OPEN indicator will light up.

3.2 Security and Alarm Functions

  • Bottone di emergenza: Premere il tasto EMERGENZA button in case of an emergency to trigger an alarm.
  • Alarm Stop: If an alarm sounds (e.g., fire, gas, security alert), press the ARRESTO ALLARME button to silence it. The red ALARM STOP indicator will light up when an alarm is active.
  • Security Display: The security display unit provides visual indicators for Fire, Gas, and Security Alert statuses.

3.3 Touch Panel Operation

The 7-inch TFT LCD is a touch panel. Navigate through menus and settings by tapping on the screen icons and options. Refer to the on-screen guide for specific menu functions.

4. Manutenzione

Regular maintenance ensures the longevity and optimal performance of your Aiphone VM-RMVU unit.

  • Pulizia: Use a soft, dry cloth to clean the unit's surface and display. Do not use abrasive cleaners or solvents.
  • Ispezione: Periodically check all connections for security and ensure no cables are damaged.
  • Aggiornamenti software: Controllare il produttore website for any available firmware updates to ensure your unit has the latest features and security enhancements.

5. Risoluzione Dei Problemi

If you encounter issues with your Aiphone VM-RMVU unit, refer to the following common troubleshooting steps:

  • Nessun potere: Ensure the power cable is securely connected and the power switch on the rear panel is ON. Check your circuit breaker.
  • Nessun video/audio: Verify all wiring connections to entrance units and sub-units. Ensure network connectivity for wireless functions.
  • Malfunzionamento dell'allarme: Check the status indicators on the security display unit. If the issue persists, contact customer support.
  • Il pannello touch non risponde: Try restarting the unit by turning the power off and on. If the problem continues, contact support.

For more complex issues, please consult a qualified technician or Aiphone customer support.

6. Specifiche

CaratteristicaSpecificazione
MarcaAiphone
Numero di modelloVM-RMVU
Potenza VoltageAC100V: 50/60Hz
Consumo energeticoStandby 6W: Max 17W
Metodo di chiamataSimultaneous Call Method
Display7-inch TFT LCD Display (Touch Panel)
Numero di pixelCirca. 1.15 milioni di pixel
Rete senza filiIEEE 802.11b/g/n (2.4 GHz)
Dimensioni del prodotto (LxWxH)Dimensioni: 18 x 22 x 4.5 cm
PesoCirca 880 g
Temperatura ambiente di esercizioda 0 a 40°C
Componenti inclusiUnità principale

7. Garanzia e supporto

For warranty information, technical support, or service inquiries, please refer to the official Aiphone website or contact your local Aiphone distributor. Keep your purchase receipt as proof of purchase.

Aiphone Ufficiale Websito: www.aiphone.com

Documenti correlati - VM-RMVU

Preview Aiphone Type GT Intercom App Operation Manual
This operation manual provides detailed instructions for using the Aiphone Type GT Intercom App on iOS and Android devices. Learn how to configure settings, answer calls, manage door releases, handle emergency alarms, and view recordings for enhanced home or building communication.
Preview Adattatore per due porte Aiphone JOW-2D per sistema videocitofonico serie JO - Guida all'installazione
Istruzioni dettagliate e specifiche per l'adattatore Aiphone JOW-2D, che consente di collegare due postazioni videocitofoniche al sistema videocitofonico della serie JO. Scopri di più su cablaggio, alimentazione e caratteristiche operative per le installazioni di videocitofoni.
Preview Guida operativa della stazione tenant Aiphone GT-1C
Manuale d'uso completo per la Tenant Station Aiphone GT-1C. Scopri di più sulla sua alimentazione, sullo schermo LCD, sull'altoparlante, sul microfono e sulle funzioni di pulsanti come Apriporta, Opzioni, Protezione, Parla e Spegnimento, oltre ai controlli laterali per luminosità, volume e zoom.
Preview Manuale di installazione e funzionamento dell'interfono portatile Aiphone AT-406/AT-306
Manuale dettagliato di installazione e funzionamento per il set interfono Aiphone AT-406 e la sottostazione AT-306, che copre componenti del sistema, caratteristiche, cablaggio, montaggio, operazioni, precauzioni tecniche, specifiche e informazioni sulla garanzia.
Preview Manuale del sistema interfonico vivavoce a due fili Aiphone DB Series
Guida completa al sistema di citofono vivavoce a due fili Aiphone DB Series, che illustra caratteristiche, componenti, cablaggio, programmazione, funzionamento e specifiche.
Preview Guida operativa della stazione principale della serie Aiphone IX
Una guida completa all'uso della Master Station della serie Aiphone IX, che descrive in dettaglio le funzioni di base, il funzionamento dei pulsanti e gli indicatori di stato.