1. Introduzione
This manual provides detailed instructions for the KAIWEETS HT206D Digital Clamp Meter and the KAIWEETS 0.8V-100V DC Smart Automotive Test Light. These instruments are designed for accurate electrical measurements and automotive circuit testing, suitable for professional and household use. Please read this manual thoroughly before operation to ensure safe and correct usage.

Image 1.1: KAIWEETS HT206D Digital Clamp Meter and KAIWEETS 0.8V-100V DC Smart Automotive Test Light.
This image displays both the KAIWEETS HT206D Digital Clamp Meter (left) and the KAIWEETS 0.8V-100V DC Smart Automotive Test Light (right). The clamp meter is red and black with a digital display and rotary dial. The test light is black with a digital display, probe, and alligator clip.
2. Informazioni sulla sicurezza
Always adhere to basic safety precautions when using electrical testing equipment to reduce the risk of fire, electric shock, or personal injury. Keep this manual for future reference.
- Non superare i valori massimi di input specificati per ciascuna funzione.
- Prestare estrema attenzione quando si lavora con il voltagsuperiori a 30 V CA RMS, 42 V di picco o 60 V CC. Questi voltagrappresentano un rischio di scossa elettrica.
- Before measuring current, ensure the instrument is properly set up and the test leads are correctly connected.
- Scollegare sempre i puntali di prova dal circuito prima di modificare le funzioni o gli intervalli.
- Prima dell'uso, ispezionare i puntali per verificare che non vi siano danni all'isolamento o parti metalliche esposte. Sostituirli se danneggiati.
- Do not operate the instrument if it appears damaged or if it is not functioning properly.
- Prima dell'uso, assicurarsi che il coperchio della batteria sia ben chiuso.
- Use caution when working in wet environments.
- For current measurement with the clamp meter, clamp around only one wire, not the entire power cord, to obtain an accurate reading.
3. Componenti del prodotto
3.1 KAIWEETS HT206D Digital Clamp metro

Image 3.1: KAIWEETS HT206D Digital Clamp Misuratore e accessori inclusi.
This image shows the KAIWEETS HT206D Digital Clamp Meter along with its accessories: two 1.5V AA batteries, red and black test leads, a K-type thermocouple, and a carrying case.
Il KAIWEETS HT206D Digital Clamp Il misuratore include:
- Cl . Digitaleamp Unità di misura
- Cavi di prova (rosso e nero)
- Termocoppia tipo K
- Custodia per il trasporto
- Manuale dell'utente (questo documento)
- Batteries (typically 2x AA or AAA, check packaging for exact type)
3.2 KAIWEETS 0.8V-100V DC Smart Automotive Test Light
The KAIWEETS 0.8V-100V DC Smart Automotive Test Light includes:
- Smart Automotive Test Light unit with coiled cable and alligator clip
- Manuale dell'utente (questo documento)
4. Impostazione
4.1 KAIWEETS HT206D Digital Clamp Meter Battery Installation
- Individuare il vano batteria sul retro del clamp metro.
- Utilizzare un cacciavite per aprire il coperchio della batteria.
- Insert the specified batteries (e.g., 2x AA 1.5V) according to the polarity markings inside the compartment.
- Riposizionare il coperchio della batteria e fissarlo con la vite.
4.2 KAIWEETS 0.8V-100V DC Smart Automotive Test Light
This device is typically powered by the circuit it is testing. No separate battery installation is required for the test light itself.
- Connect the alligator clip to a suitable ground point (e.g., vehicle chassis for automotive applications).
- Assicurarsi che la punta della sonda sia pulita e priva di detriti.
5. Istruzioni per l'uso
5.1 KAIWEETS HT206D Digital Clamp metro
Turn the rotary dial to select the desired measurement function.
5.1.1 Misurazione della corrente CA/CC (Clamp)
- Turn the rotary dial to the "600A" or "60A" AC/DC current range.
- Aprire il clamp jaws and enclose a single conductor. Ensure the conductor is centered within the jaws.
- Leggere il valore corrente sul display.
- Importante: To measure current, the clamp must enclose only one conductor. Clamping around an entire power cord (which contains both live and neutral wires) will result in a zero reading.

Image 5.1.1: KAIWEETS HT206D Digital Clamp Meter measuring current.
This image shows the KAIWEETS HT206D Digital Clamp Meter in use, clamping around a single electrical wire to measure current. The display shows a reading of "270.1 AC".
5.1.2 CA/CC voltage, Resistance, Capacitance, Frequency, Diode, Continuity, Temperature Measurement
- Collegare il puntale di prova rosso al jack di ingresso "VΩHz" e il puntale di prova nero al jack di ingresso "COM".
- Ruotare la manopola sulla funzione desiderata (ad esempio, V~ per AC Voltage, V- per DC Voltage, Ω per resistenza, ecc.).
- For temperature measurement, connect the K-type thermocouple to the appropriate input jacks (usually marked with temperature symbols) and select the temperature function.
- Apply the test leads or thermocouple to the circuit or component under test.
- Leggere la misura sul display.

Image 5.1.2: KAIWEETS HT206D Digital Clamp Meter performing temperature measurement.
This image illustrates the KAIWEETS HT206D Digital Clamp Meter measuring temperature using the included K-type thermocouple. Examples show measurements in liquid, gas, and solid states, with a temperature range of -4°F to 1832°F.
5.1.3 NCV (Volume senza contattotage) Rilevamento
- Press the NCV button (located on the right side of the meter).
- Sposta la parte superiore del clamp contatore vicino a un conduttore sotto tensione.
- Il misuratore indicherà la presenza di tensione alternatatage tramite un segnale acustico e/o un indicatore visivo.

Image 5.1.3: KAIWEETS HT206D Digital Clamp Meter NCV and HOLD functions.
This image demonstrates two functions of the clamp meter. On the left, the NCV (Non-Contact Voltage) function is shown detecting voltage near an outlet. On the right, the HOLD function is activated by a short press of the 'H' button, freezing the display reading.
5.1.4 LowZ & LPF Functions
- LowZ (Low Input Impedance): Helps prevent false readings caused by "ghost voltages" in circuits. Select this mode when ghost voltages are suspected.
- LPF (filtro passa basso): Used for accurate measurement of variable frequency drive (VFD) signals, common in motor and transformer applications.
5.1.5 Data Hold (MAX/MIN)
- Press the "HOLD" button to freeze the current display reading. Press again to release.
- Press the "MAX/MIN" button to record the maximum or minimum values during a measurement session.
5.2 KAIWEETS 0.8V-100V DC Smart Automotive Test Light
5.2.1 Smart Mode Operation
The test light defaults to Smart Mode, automatically detecting and measuring DC voltage, continuità e resistenza senza selezione manuale dell'intervallo.
- Ensure the alligator clip is securely connected to a ground point.
- Touch the probe tip to the circuit or component to be tested.
- The display will automatically show the detected measurement type (DC Voltage, Continuity, or Resistance) and its value.

Image 5.2.1: KAIWEETS 0.8V-100V DC Smart Automotive Test Light in Smart Mode.
This image highlights the "Smart Mode" feature of the automotive test light, which automatically recognizes and measures DC Voltage, Resistance, and Continuity. The test light is shown in an automotive fuse box, demonstrating its application.
5.2.2 Wide Testing Range (0.8V-100V DC)
The test light can accurately measure DC voltages from 0.8V to 100V. If the voltage exceeds 100V, the display will show "OL" (Overload) as a warning.

Image 5.2.2: KAIWEETS 0.8V-100V DC Smart Automotive Test Light wide testing range.
This image demonstrates the test light's 0.8V-100V wide testing range, showing it connected to a car battery terminal. The display shows a voltage reading, and an inset illustrates the "OL" (Over-range warning) display for values exceeding 100V.
5.2.3 Torcia e retroilluminazione
- Press the flashlight button to activate the built-in flashlight for illuminating the work area.
- The green backlight display enhances readability in low-light conditions.

Image 5.2.3: KAIWEETS 0.8V-100V DC Smart Automotive Test Light with flashlight and backlight.
This image shows the automotive test light being used in a dark environment, highlighting its green backlight display and bright flashlight feature, which aids visibility during operation.
5.2.4 Buzzer Alarm for Continuity
When testing for continuity (typically less than 50Ω), the test light will emit an audible buzzer alarm to indicate a continuous circuit.

Image 5.2.4: KAIWEETS 0.8V-100V DC Smart Automotive Test Light buzzer alarm.
This image illustrates the buzzer alarm feature of the test light, which activates when testing for continuity (less than 50Ω). The test light is shown connected to a circuit, with visual cues indicating the sound waves from the buzzer.
6. Manutenzione
- Pulizia: Pulisci lo strumento con adamp panno e detersivo delicato. Non utilizzare abrasivi o solventi.
- Battery Replacement (HT206D Clamp Meter): Quando sul display compare l'indicatore di batteria scarica, sostituire le batterie come descritto nella Sezione 4.1.
- Magazzinaggio: Store the instruments in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for extended periods, remove batteries from the clamp metro.
- Ispezione della sonda e del cavo: Regularly inspect test leads and probes for any signs of damage, such as cuts, cracks, or exposed wiring. Replace damaged components immediately.
7. Risoluzione Dei Problemi
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Clamp Il misuratore non si accende. | Batterie scariche o installate in modo errato. | Controllare la polarità delle batterie; sostituire le batterie. |
| Clamp Meter shows "OL" (Overload). | La misurazione supera l'intervallo selezionato o la capacità massima dello strumento. | Select a higher range if available, or ensure the measurement is within the instrument's specifications. |
| Clamp Meter current reading is zero. | Clamping around multiple conductors (e.g., a power cord). | Garantire il clamp jaws enclose only a single conductor. |
| Test Light shows "OL". | DC volumetage supera i 100 V. | il volumetage is outside the test light's measurement range. Use a different instrument for higher voltages. |
| Letture imprecise. | Poor contact, damaged leads, or incorrect function selection. | Ensure good contact, inspect and replace leads if damaged, verify correct function is selected. |
8. Specifiche
8.1 KAIWEETS HT206D Digital Clamp metro
- Funzioni di misurazione: Corrente CA/CC, Vol. CA/CCtage, Resistance, Capacitance, Frequency/Duty Cycle, Diode, Continuity, Temperature
- Caratteristiche speciali: True-RMS, LowZ, LPF, NCV Detection, Data Hold (MAX/MIN)
- Valutazione di sicurezza: CAT III 600V (refer to device for exact rating)
- Fonte di energia: Battery Powered (e.g., 2x AA 1.5V)
8.2 KAIWEETS 0.8V-100V DC Smart Automotive Test Light
- Funzioni di misurazione: Volume DCtage, Continuity, Resistance (Smart Mode auto-detection)
- Gamma di test: 0.8V - 100V CC
- Caratteristiche speciali: Smart Mode, Flashlight, Green Backlight Display, Buzzer Alarm
- min. Operativo Voltage: 0.8 Volt (CC)
- Valutazione di sicurezza: 300V CAT III (refer to device for exact rating)
9. Garanzia e supporto
I prodotti KAIWEETS sono progettati per garantire affidabilità e prestazioni. Per informazioni sulla garanzia, supporto tecnico o richieste di assistenza, consultare il sito ufficiale KAIWEETS. weboppure contatta direttamente il servizio clienti. Conserva la ricevuta d'acquisto come prova d'acquisto.
KAIWEETS Ufficiale Websito: www.kaiweets.com