1. Introduzione
This manual provides detailed instructions for the installation, operation, and maintenance of your DEWIN Automatic Reclosing Residual Current Circuit Breaker (RCCB). Please read this manual thoroughly before installation and use to ensure safe and efficient operation. This device is designed to automatically reclose the circuit after an accidental trip, minimizing downtime and enhancing electrical safety.
2. Informazioni importanti sulla sicurezza
- Installazione professionale richiesta: Installation and maintenance of this device must be performed by qualified electricians in accordance with local electrical codes and regulations.
- Disconnessione dell'alimentazione: Always disconnect power to the circuit before installing, servicing, or performing any work on the device.
- Voltage e valori attuali: Assicurare il volume del dispositivotage (AC230V) and current (40A) ratings match your electrical system requirements.
- Nota sul display LED: The LED display on this model does not show voltage parametri.
- Initial Lock: After factory testing, the device may be in a locked state. Power on the unit and manually pull the reset lock to release it.
- Restrizione dell'applicazione: This product is not suitable for personal photovoltaic (solar) installations in homes.
3. Caratteristiche del prodotto
- Richiusura automatica intelligente: Automatically recloses the circuit when the RCCB trips accidentally, eliminating the need for manual intervention and reducing maintenance costs.
- Type A Protection: Provides protection against sinusoidal AC, pulsating DC, and pulsating half-wave + DC residual currents, ensuring stable performance.
- Commutazione automatica/manuale: Offers both automatic (AUTO) and manual (MANU) operation modes. In AUTO mode, reclosing occurs automatically after a fault. In MANU mode, manual reset is required.
- Modalità autobloccante: Features a progressive reclosing delay (9s, 59s, 299s) after successive faults. After the fourth fault, the device enters a self-locking mode, requiring manual inspection and reset for safety.
- Display LED digitale: Provides clear visual feedback on the device's status. Red flashing indicates opening, green flashing indicates closing in AUTO mode. A yellow light is always on for manual operation. The display also shows the number of trips and reclosing recovery time.
- Ampia applicazione: Suitable for various applications such as unmanned mobile phone base stations, elevators, smart homes, smart factories, and new energy vehicle charging stations.
- Costruzione durevole: Made from PC material with IP20 protection grade.
- Installazione su guida DIN: Designed for easy installation on a 35mm DIN rail.
4. Specifiche tecniche
| Specificazione | Valore |
|---|---|
| Marca | DEVINCE |
| Numero di modello | QDXCXDQDC-GS99306-02 |
| Corrente nominale | 40 Ampqui |
| Rated Residual Current | 30mA |
| Poli | 2P |
| Volume nominaletage | AC230V |
| Tipo | Tipo A |
| Tipo di montaggio | Guida DIN |
| Peso dell'articolo | 350 grammi |
| Dimensioni del pacco | Dimensioni: 12.4 x 11.7 x 8.9 cm |
| Frequenza di lavoro | Frequenza 50/60 Hz |
| Tempo di chiusura dell'azione | <1 secondi |
| Ora di apertura dell'azione | <0.5 secondi |
| Durata effettiva del segnale di controllo | >400ms |
Dimensioni del prodotto

Descrizione dell'immagine: This image displays the physical dimensions of the DEWIN Automatic Reclosing RCCB, showing measurements for height (82mm), width (49mm), and depth (54mm). It also includes a basic electrical circuit diagram illustrating the connections for the device.
5. Installazione e cablaggio
Proper installation is crucial for the safe and correct operation of the DEWIN RCCB. Refer to the wiring diagram below and ensure all connections are secure and comply with local electrical standards.
Schema elettrico

Descrizione dell'immagine: This diagram illustrates the electrical connections for the DEWIN Automatic Reclosing RCCB. It shows the incoming Line (L) and Neutral (N) connections, the output to various loads, and the auxiliary control connections for external opening and closing buttons. Note that for automatic reclosing, an external button is not required, but for manual control, a normally open self-reset button is used.
Fasi di cablaggio:
- Mount the RCCB securely on a 35mm DIN rail within your electrical panel.
- Connect the incoming Line (L) and Neutral (N) wires to the designated input terminals of the RCCB.
- Connect the load wires to the output terminals of the RCCB.
- For auxiliary control, connect external opening and closing buttons to the respective terminals (OPEN, CLOSE, COM). Ensure that for manual control, a normally open self-reset button is used.
- Verify all connections are tight and correct before restoring power.
Video dimostrativo dell'installazione
Descrizione del video: This video demonstrates the physical installation and basic wiring of the DEWIN Automatic Reclosing Residual Current Circuit Breaker, showing how to connect the main power lines and load. It highlights the secure fastening of wires into the terminals.
Descrizione del video: This video provides a visual guide to the installation process of the Automatic Reclosing Residual Current Circuit Breaker, including mounting on a DIN rail and connecting electrical wires. It shows the device in a typical electrical box setup.
6. Istruzioni per l'uso
The DEWIN RCCB offers both automatic and manual operating modes, indicated by the 'AUTO' and 'MANU' selector switch.
Operating Modes and LED Display

Descrizione dell'immagine: This diagram details the automatic and manual switching modes of the DEWIN RCCB, along with the corresponding LED digital display indicators. It explains that in AUTO mode, red flashing indicates opening and green flashing indicates closing, while in MANU mode, a yellow light is always on for manual operation. The display also shows trip count and reclosing recovery time.
- Modalità automatica: In this mode, the circuit breaker will automatically attempt to restore power after a fault. The LED display will show:
- Red flashing: Indicates the circuit is open (tripped).
- Green flashing: Indicates the circuit is closed (reclosed).
- Modalità MANU: In this mode, if a fault occurs, the circuit breaker must be manually reset. The LED display will show:
- Yellow light always on: Indicates manual opening and closing operation.
- Visualizzazione del codice non funzionante: The digital display shows the number of times the circuit has tripped and reclosed, along with the countdown time for reclosing recovery.
Self-Locking Mode

Descrizione dell'immagine: This image illustrates the self-locking mechanism of the DEWIN RCCB. It shows the progressive reclosing delays after a circuit fault: 9 seconds for the first reclosure, 59 seconds for the second, and 299 seconds for the third. After the fourth fault, the device enters a self-locking mode, requiring manual intervention. The image also includes a table defining different waveform types (AC, A) and their action ranges.
To prevent continuous reclosing into a persistent fault, the device implements a self-locking mechanism:
- Primo errore: The circuit automatically recloses after 9 seconds.
- Secondo errore: The circuit automatically recloses after 59 seconds.
- Terzo errore: The circuit automatically recloses after 299 seconds.
- Quarto errore: The recloser enters a self-locking mode. Manual inspection of the circuit and a manual reset operation are required before the device can be reclosed.
Nota: When the 'LOCK' mechanism is engaged (pulled up), the circuit breaker cannot be closed. This feature is designed to protect electrical safety and prevent accidental contact during inspection or maintenance.
7. Manutenzione
Regular maintenance ensures the longevity and reliability of your DEWIN RCCB.
- Test mensile: Press the 'Test Monthly' button on the device to verify its tripping function. The device should trip, and then reclose according to its programmed reclosing sequence (if in AUTO mode).
- Pulizia: Mantenere il dispositivo pulito e privo di polvere e detriti. Utilizzare un panno asciutto e morbido per la pulizia. Non utilizzare liquidi o detergenti abrasivi.
- Ispezione: Controllare periodicamente i collegamenti dei cavi per verificarne la tenuta e l'eventuale presenza di segni di usura o danni.
8. Risoluzione Dei Problemi
If you encounter issues with your DEWIN RCCB, refer to the following common problems and solutions:
- Device is Locked After Installation: If the device does not operate after initial power-up, it might be in a factory-locked state. Manually pull up the 'LOCK' mechanism to release it.
- LED Display Not Showing Voltage: This is normal operation. The LED display on this model is designed to indicate operational status and trip count, not voltage parametri.
- Device Enters Self-Locking Mode Frequently: Frequent tripping and entry into self-locking mode (after 4 consecutive faults) indicates a persistent electrical fault in the circuit. Disconnect power, thoroughly inspect the connected load and wiring for shorts, overloads, or ground faults, and rectify the issue before manually resetting the RCCB.
- Device Does Not Reclose in AUTO Mode: Ensure the selector switch is correctly set to 'AUTO'. If the device has entered self-locking mode due to multiple faults, it will require manual reset after fault clearance.
- Device Does Not Respond to Manual Operation: If in MANU mode, ensure the 'LOCK' mechanism is not pulled up. If it is, push it down to allow manual operation.
If the problem persists after attempting these troubleshooting steps, contact a qualified electrician or DEWIN customer support for assistance.
9. Garanzia e supporto
Specific warranty details are not provided in the product information. For warranty claims, technical support, or service inquiries, please refer to the seller's return policy or contact DEWIN customer service directly through their official channels or the retailer where the product was purchased.