1. Introduzione
This manual provides instructions for the safe and effective use of the KAIWEETS KC604 Digital Clamp Meter Multimeter and the KET12 Soft Silicone Electrician Test Leads Kit. Please read this manual thoroughly before operation and retain it for future reference. This kit is designed for professional and DIY electrical testing, offering a range of measurement capabilities for various applications.
2. Informazioni sulla sicurezza
Always adhere to safety precautions when using electrical testing equipment. Failure to do so may result in injury or damage to the device. This device is designed for safe operation when used according to these instructions.
- Do not exceed the maximum input values for any function. The KC604 is rated for CAT III 1000V and CAT IV 600V.
- Prima di effettuare le misurazioni, assicurarsi che i puntali di prova siano collegati correttamente e che l'interruttore di funzione sia impostato sulla gamma corretta.
- Always use appropriate personal protective equipment (PPE) such as safety glasses and insulated gloves when working with electrical circuits.
- Inspect test leads for damage before each use. Do not use if insulation is compromised or if there are any signs of wear.
- Avoid touching exposed conductors or circuit components when power is applied.
- Non utilizzare il misuratore se appare danneggiato o non funziona correttamente.
- Sostituire tempestivamente le batterie quando compare l'indicatore di batteria scarica per garantire letture accurate e il corretto funzionamento del dispositivo.
- Never attempt to measure current on a circuit with the test leads; use the clamp function for current measurements.

Image: An electrician safely using the KAIWEETS KC604 Digital Clamp Meter to perform measurements within an electrical panel, highlighting its application in a professional setting.
3. Prodotto finitoview
3.1 KAIWEETS KC604 Digital Clamp metro
The KAIWEETS KC604 is a versatile digital clamp misuratore progettato per misurare la corrente AC/DC, la tensione AC/DCtage, resistance, continuity, diode, capacitance, frequency, and temperature. It features a D-shaped jaw for clamping around conductors and a clear digital display with backlight and flashlight functions for improved visibility in various environments.

Immagine: KAIWEETS KC604 Digital Clamp Misuratore, mostraasing its main components including the clamp jaw, function dial, and LCD display.
3.2 KAIWEETS KET12 Soft Silicone Electrician Test Leads Kit
The KET12 kit provides high-quality, flexible silicone test leads with interchangeable connectors, including alligator clips, needle probes, and mini-hooks, for various testing applications. These leads are double-insulated, rated for CAT III 1000V & CAT IV 600V, and can handle a 10A current, ensuring safety and versatility.

Image: Components of the KET12 Test Leads Kit, including two alligator clips, two test probes, two test hooks, and a test lead with an SMD tweezer, demonstrating the interchangeable nature of the connectors.
4. Impostazione
4.1 Installazione della batteria
The KC604 requires batteries for operation. To install or replace batteries, locate the battery compartment on the back of the device. Use a screwdriver to open the compartment, insert the batteries according to the polarity markings, and then securely close the compartment. Refer to the device markings for the correct battery type (e.g., AAA or 9V).
4.2 Collegamento dei puntali di prova
Per la maggior parte dei volumitage, resistance, continuity, diode, capacitance, and frequency measurements, insert the red test lead into the "VΩmA" input jack and the black test lead into the "COM" input jack. Ensure the connections are firm. For current measurements using the clamp function, test leads are not required for the main current path.

Image: An illustration showing test leads properly connected to a multimeter's input jacks, demonstrating the correct setup for various electrical measurements.
5. Istruzioni per l'uso
5.1 Accensione/spegnimento
Rotate the function dial from the "OFF" position to any desired measurement function to power on the device. To power off, rotate the function dial back to "OFF". The device features an auto-shutdown function after a period of inactivity to conserve battery life.
5.2 Misurazione della corrente CA/CC (Clamp Funzione)
Rotate the function dial to the appropriate AC or DC current range (e.g., 40A, 400A). Open the clamp jaw and carefully enclose a single conductor. Ensure the jaw is fully closed. The current value will be displayed on the LCD. Do not clamp around multiple conductors as this will result in an inaccurate reading.

Image: The KAIWEETS KC604 clamp meter actively measuring AC/DC current by securely clamping around a single electrical wire, displaying the reading on its screen.
5.3 Misurazione del volume AC/DCtage
Rotate the function dial to the AC V or DC V range. Connect the red and black test leads in parallel to the circuit or component where voltage is to be measured. The voltage value will be displayed on the LCD. Always ensure the correct voltage type (AC or DC) is selected.

Image: The KAIWEETS KC604 clamp meter measuring AC/DC voltage using its connected test leads, with the voltage reading visible on the display.
5.4 Misurazione della temperatura
Rotate the function dial to the temperature function (°C/°F). Connect the temperature probe (typically a K-type thermocouple, if included) to the meter's input jacks. Place the tip of the probe on the object whose temperature is to be measured. The temperature will be displayed in Celsius or Fahrenheit.

Image: The KAIWEETS KC604 clamp meter measuring temperature using a connected temperature probe, showing the temperature reading on its display.
5.5 Other Functions (Resistance, Continuity, Diode, Capacitance, Frequency)
For these functions, rotate the function dial to the corresponding symbol. Connect the test leads to the appropriate input jacks and across the component or circuit being tested. Always ensure the circuit is de-energized before measuring resistance, continuity, diode, or capacitance.
- Resistenza (Ω): Measures electrical resistance in Ohms.
- Continuità (cicalino): Indicates a complete circuit with an audible tone and low resistance reading.
- Diode (►|--): Tests diode functionality and forward voltage goccia.
- Capacità (F): Misura la capacità in Farad.
- Frequenza (Hz%): Misura la frequenza di un segnale CA.
5.6 MAX/MIN and HOLD Functions
IL Massimo/minimo button allows the meter to capture and display the maximum and minimum readings during a measurement session. Pressing it cycles through MAX, MIN, and current readings. The PRESA button freezes the current reading on the display, which is useful for recording measurements in hard-to-reach areas.
6. Manutenzione
6.1 Pulizia
Pulisci il misuratore e i puntali con un pannoamp cloth and mild detergent. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the casing or display. Ensure the device is powered off and disconnected from any circuits before cleaning.
6.2 Sostituzione della batteria
When the low battery indicator appears on the display, replace the batteries immediately to ensure accurate readings and proper device functionality. Refer to the battery compartment cover for the correct battery type and ensure proper polarity during installation.
6.3 Cura del puntale di prova
Store test leads properly to prevent kinking, sharp bends, or damage to the insulation. Regularly inspect the test leads for any cuts, cracks, or other signs of wear. Damaged test leads should be replaced immediately to maintain safety and measurement accuracy.

Immagine: un primo piano view of the flexible, double-insulated silicone test leads, emphasizing their durable and soft construction for long-lasting use.
7. Risoluzione Dei Problemi
7.1 Problemi comuni e soluzioni
- Nessun display/alimentazione: Check battery installation and charge. Ensure the function dial is not on the "OFF" position. Replace batteries if necessary.
- Letture imprecise: Verify correct function selection and test lead connection. Check for damaged test leads. Ensure the clamp jaw is fully closed around a single conductor for current measurements. Ensure the circuit is de-energized for resistance/continuity tests.
- Nessun segnale acustico di continuità: Ensure the circuit is de-energized. Check for open circuits or high resistance in the component being tested.
- Il display mostra "OL" (sovraccarico): The measured value exceeds the selected range. Select a higher range or ensure the input is within the device's specifications.
8. Specifiche
8.1 KAIWEETS KC604 Digital Clamp metro
- Valutazione di sicurezza: CAT III 1000 V, CAT IV 600 V
- Display: Display digitale a 4000 conteggi
- AC/DC Current Range: Up to 400A (via clamp)
- Volume AC/DCtage Gamma: Fino a 1000V
- Intervallo di temperatura: Da -4°C a 1832°C (da -20°F a 1000°F)
- Caratteristiche: Auto-shutdown, Backlight, Flashlight, Low battery indication, NCV (Non-Contact Voltage) detection, MAX/MIN, HOLD functions.
8.2 KAIWEETS KET12 Test Leads Kit
- Valutazione di sicurezza: CAT III 1000 V, CAT IV 600 V
- Valutazione attuale: 10A
- Materiale: Soft Silicone Double Insulated
- Lunghezza del filo: Circa 48 pollici (122 cm)
- Wire Core: Composed of 105pcs 0.001mm copper wires and nylon yarn for excellent tensile strength and low resistance.
- Connettori: Interchangeable alligator clips, needle probes, and mini-hooks.
9. Garanzia e supporto
9.1 Informazioni sulla garanzia
KAIWEETS provides a 36-month after-sale service for this product. This warranty covers manufacturing defects and ensures the product meets its specified performance. Please retain your proof of purchase for warranty claims.
Informazioni di contatto 9.2
For warranty claims, technical support, or any inquiries regarding the KAIWEETS KC604 Digital Clamp Meter and KET12 Test Leads Kit, please contact KAIWEETS customer service through their official website or the retailer where the product was purchased. Detailed contact information can typically be found in your product packaging or on the KAIWEETS official support page.