Elitech DR-230-THE

Elitech DR-230-THE Bluetooth Hygrometer Thermometer

Manuale di istruzioni

1. Prodotto finitoview

The Elitech DR-230-THE is a Bluetooth-enabled hygrometer and thermometer designed for precise temperature and humidity monitoring. It features a large display, extensive data storage, and smart alarm capabilities, making it suitable for various environments such as warehouses, laboratories, and cold storage facilities.

Elitech DR-230-THE Bluetooth Hygrometer Thermometer with external alarm

Figure 1: Elitech DR-230-THE device with external alarm and sensor.

2. Caratteristiche principali

  • 10.6-inch Jumbo Display: Provides clear visibility of temperature and humidity readings across large spaces.
  • 30,000 Data Points Storage: Robust cyclic storage capacity with automatic overwrite to ensure continuous data recording.
  • Dual-Channel Monitoring: Simultaneously track two zones using external sensors.
  • Avvisi intelligenti: Customizable alarms including screen flashing and an optional 110dB external siren with adjustable delays.
  • Connettività Bluetooth: Monitor data remotely via the Elitech iCold app (up to 147ft range).
  • Universal Power & Flexible Installation: Supports 100–240V power input with interchangeable plugs and offers wall-mounting or desktop stand options.

3. Impostazione

3.1 Contenuto della confezione

Verificare che tutti i componenti siano presenti:

  • Elitech DR-230-THE device
  • External temperature/humidity sensor(s)
  • External alarm (optional, if included with model)
  • Power adapter with interchangeable plugs (US, EU, UK, China standards)
  • Accessori di montaggio (viti, tasselli a muro)
  • Manuale dell'utente (questo documento)

3.2 Alimentazione del dispositivo

  1. Seleziona la spina di alimentazione appropriata per la tua regione e collegala all'adattatore di alimentazione.
  2. Connect the power adapter to the Power Supply Interface on the back of the DR-230-THE device.
  3. Plug the power adapter into a standard 100–240V AC outlet. The device will power on automatically.

3.3 Sensor and Alarm Connection

  1. Locate the External Sensor Interface on the back of the device. Connect the external temperature/humidity sensor(s) to these ports.
  2. If your model includes an external alarm, connect it to the External Siren Interface.
Indietro view of Elitech DR-230-THE showing connection ports

Figure 2: Back panel connections including wall-mounting hole, external sensor interface, external siren interface, and power supply interface.

3.4 Opzioni di installazione

The DR-230-THE offers flexible installation:

  • Supporto da tavolo: Utilize the integrated back bracket for stable placement on any flat surface.
  • Montaggio a parete: Use the wall-mounting hole and provided screws to secure the device to a wall. Ensure the wall can support the device's weight.

4. Istruzioni per l'uso

4.1 Fine displayview

The 10.6-inch display provides real-time information:

Elitech DR-230-THE 4-in-1 display showing temperature, humidity, date, and time

Figure 3: The 4-in-1 display shows temperature, humidity, date, and time. Device dimensions are approximately 8.5" (21.5cm) length and 6.5" (16.5cm) width.

  • CH: 2: Indicates dual-channel monitoring is active.
  • Icona della temperatura: Visualizza la lettura della temperatura attuale.
  • Icona umidità: Displays the current relative humidity reading.
  • Data e ora: Mostra la data e l'ora correnti.

4.2 Connettività Bluetooth e integrazione delle app

The Elitech iCold app allows for remote monitoring and configuration:

  1. Download the Elitech iCold app from your smartphone's app store.
  2. Assicurati che il Bluetooth sia abilitato sul tuo smartphone.
  3. Open the Elitech iCold app and follow the on-screen instructions to connect to your DR-230-THE device.
  4. Una volta connesso, puoi view real-time graphs, configure parameters, and access automatic data recording.
Elitech iCold app interface showing data graph, real-time data, parameter configuration, and data export options

Figure 4: The Elitech iCold app provides real-time charts and instant PDF reports.

4.3 Registrazione ed esportazione dei dati

The device automatically stores up to 30,000 data points. Old data is overwritten once the storage capacity is reached.

  • Through the Elitech iCold app, users can export real-time charts and instant PDF reports for data analysis and record-keeping.
Elitech DR-230-THE display showing temperature and humidity readings with '30,000 Data Points' text overlay

Figure 5: The device stores 30,000 data points, ensuring critical information is retained.

4.4 Configurazione allarmi

The DR-230-THE features customizable alarms:

  • Schermo lampeggiante: The device screen will flash when readings exceed set thresholds.
  • External Siren: If connected, the optional 110dB external siren will activate.
  • Ritardo regolabile: Alarm delays can be set between 3 to 10 seconds to prevent false alerts from transient fluctuations.

Alarm thresholds and delays are configured via the Elitech iCold app.

Elitech DR-230-THE with external siren in a wine cellar, illustrating screen flashing and siren alert

Figure 6: Screen flashing and optional 110dB external siren provide smart alerts with adjustable delays.

5. Manutenzione

  • Pulizia: Wipe the device and sensors with a soft, dry cloth. Do not use abrasive cleaners or immerse the device in water.
  • Cura del sensore: Keep sensors free from dust and debris to ensure accurate readings. Avoid exposing sensors to extreme physical shock or corrosive substances.
  • Magazzinaggio: Quando non viene utilizzato per lunghi periodi, conservare il dispositivo in un luogo fresco e asciutto, lontano dalla luce solare diretta.

6. Risoluzione Dei Problemi

Problema Possibile causa Soluzione
Il dispositivo non si accende. Nessun alimentatore o adattatore difettoso. Check power connection. Ensure adapter is securely plugged into device and outlet. Try a different outlet.
Letture imprecise. Sensor obstruction or damage; device placed in an unsuitable environment. Ensure sensors are clean and unobstructed. Relocate the device to a stable environment away from direct heat sources or drafts.
Problemi di connessione Bluetooth. Bluetooth off; device out of range; app issues. Ensure Bluetooth is enabled on your phone. Move closer to the device (within 147ft). Restart the app or your phone.
L'allarme non si attiva. Alarm thresholds not set correctly; alarm delay too long; external siren disconnected. Verify alarm settings in the Elitech iCold app. Check external siren connection.

7. Specifiche

  • Dimensioni dello schermo: 10.6 pollici
  • Archiviazione dati: 30,000 data points (auto-overwrite)
  • Monitoring Channels: Dual (with external sensors)
  • Tipo di allarme: Screen flashing, optional 110dB external siren
  • Ritardo allarme: Adjustable (3–10 seconds)
  • Connettività: Bluetooth (up to 147ft range)
  • Potenza in ingresso: 100–240 V CA
  • Installazione: Wall-mounting, desktop stand

8. Garanzia e supporto

For warranty information and technical support, please refer to the official Elitech website or contact Elitech customer service directly. Keep your purchase receipt as proof of purchase.

Elitech Technology Inc.
Informazioni sul venditore

Documenti correlati - DR-230-THE

Preview Istruzioni per il registratore di temperatura e umidità Elitech DR-230
Manuale utente e istruzioni per il registratore di temperatura e umidità Elitech DR-230, che descrive in dettaglio le caratteristiche del prodotto, l'interfaccia, le specifiche tecniche, la configurazione e il funzionamento tramite l'applicazione mobile Elitech iCold per il monitoraggio e la registrazione dei dati.
Preview Registratore di temperatura e umidità Elitech DR-230: istruzioni e manuale
Guida completa al registratore di temperatura e umidità Elitech DR-230, che descrive in dettaglio il suo prodottoview, caratteristiche, interfaccia, specifiche tecniche, funzionamento manuale e istruzioni dettagliate per l'utilizzo dell'applicazione mobile Elitech iCold.
Preview Manuale utente del data logger di temperatura e umidità Elitech RC-61/GSP-6
Manuale utente completo per il data logger di temperatura e umidità Elitech RC-61/GSP-6. Scopri le sue caratteristiche, le specifiche, il funzionamento, le indicazioni di stato, la sostituzione della batteria e i parametri predefiniti.
Preview Istruzioni per il registratore di temperatura e umidità Elitech DR-230
Manuale utente per il registratore di temperatura e umidità Elitech DR-230, che descrive in dettaglio le caratteristiche del prodotto, l'interfaccia, la struttura, le specifiche tecniche e il funzionamento dell'app per il monitoraggio e la registrazione dei dati.
Preview Manuale utente Elitech LogEt 5i: registratore dati IoT monouso
Manuale utente completo per il data logger IoT monouso Elitech LogEt 5i. Include caratteristiche del prodotto, specifiche tecniche, istruzioni per l'uso, precauzioni di sicurezza e gestione dei dati per il monitoraggio di temperatura, umidità e luce nelle applicazioni logistiche e della catena del freddo.
Preview Manuale utente del registratore dati multiuso di temperatura e umidità Elitech GSP-6
Guida completa al data logger Elitech GSP-6, che ne illustra le caratteristiche, le specifiche, il funzionamento, la gestione dei dati e la risoluzione dei problemi per il monitoraggio della temperatura e dell'umidità nella logistica della catena del freddo.