1. Introduzione
The ZIBOO ET1013 Digital Manometer is a precision instrument designed for measuring gauge and differential pressure in various applications. It offers 11 selectable pressure units and features data hold, recording, and zero functions for accurate and reliable measurements. This manual provides essential information for the safe and effective use of your manometer.
2. Informazioni sulla sicurezza
Per evitare lesioni e danni allo strumento, osservare sempre le seguenti precauzioni di sicurezza:
- Non superare la pressione nominale massima del dispositivo.
- Ensure proper connection of pressure tubes to avoid leaks or disconnections during operation.
- Tenere il dispositivo lontano da temperature estreme, umidità e ambienti corrosivi.
- Do not attempt to disassemble or modify the instrument. Refer servicing to qualified personnel.
- Rimuovere le batterie se il dispositivo non verrà utilizzato per un periodo prolungato.
3. Contenuto della confezione
Verificare che tutti gli articoli siano presenti nel pacco:
- 1 x ZIBOO ET1013 Digital Manometer
- 1 x Borsa portautensili
- 1 Pair x RMA316 Manometer Tube Adapter
- 4 x Soft Tubes
- 1 x Manuale utente

Figure 3.1: Contents included in the ZIBOO ET1013 package.
4. Prodotto finitoview
4.1. Disposizione e funzioni del dispositivo

Figura 4.1: Fronte view of the ZIBOO ET1013 Digital Manometer with key functions labeled.
- Pulsante UNITÀ: Cycles through 11 selectable pressure units.
- Pulsante ATTESA: Freezes the current displayed reading. Press again to release.
- DIF Button: Activates differential pressure mode, displaying the difference between two pressure inputs.
- Pulsante REC: Enters recording mode to view maximum, minimum, and average values. Long press to exit.
- Pulsante retroilluminazione: Toggles the LCD backlight on/off for improved visibility in low-light conditions.
- Pulsante di accensione: Accende o spegne il dispositivo.
4.2. Interfaccia display LCD

Figura 4.2: dettagliata view of the LCD display showing various indicators and readings.
The large LCD display provides clear readings, including:
- Differential Pressure Mode indicator.
- Hold Data indicator.
- Pressure Measurement value.
- MIN/MAX/AVG recording mode indicators.
- Selected Pressure Unit.
4.3. Dual Channel Inputs

Figure 4.3: The dual channel input ports for pressure measurement.
The manometer features two input ports for measuring differential pressure. These ports are clearly marked with '+' and '-' for positive and negative pressure connections.
4.4. Dimensioni

Figure 4.4: Physical dimensions of the ZIBOO ET1013 Digital Manometer.
The compact and slim design (approximately 5.79" x 2.16" x 1.26") allows for easy one-handed operation and portability.
5. Impostazione
5.1. Installazione della batteria
The ZIBOO ET1013 Manometer requires a 9V battery (not included). To install:
- Individuare il coperchio del vano batteria sul retro del dispositivo.
- Utilizzare un piccolo cacciavite per aprire il vano batteria.
- Inserire una nuova batteria da 9 V, assicurandosi della corretta polarità.
- Chiudere saldamente il coperchio del vano batterie.
Video 5.1: Unboxing and battery installation for a similar digital manometer. This demonstrates the general process for installing the 9V battery.
5.2. Collegamento dei tubi di pressione
Connect the provided soft tubes to the manometer's input ports and to the pressure source you wish to measure.
- Attach one end of a soft tube to the '+' port on the manometer.
- Attach the other end of the tube to the high-pressure side of your system.
- For differential pressure, attach a second soft tube to the '-' port and to the low-pressure side of your system.
- Use the RMA316 tube adapters if required for specific connections.

Figura 5.2: Esample of connecting a soft tube to a pagoda pressure connector.
6. Istruzioni per l'uso
6.1. Accensione/spegnimento
Premere il tasto Energia button to turn the manometer on. The device will perform a self-test and display readings. To turn off, press the Energia button again. The device features an auto power-off function after 20 minutes of inactivity to conserve battery life.
6.2. Selezione dell'unità
Premere il tasto UNITÀ button to cycle through the 11 available pressure units (e.g., psi, kPa, bar, inHg, mmHg, inH₂O, ftH₂O, cmH₂O, ozin², kgfcm², mbar). The selected unit will be displayed on the LCD.
Video 6.1: Demonstration of unit selection and other basic operations on a digital manometer.
6.3. Conservazione dei dati
Premere il tasto PRESA button to freeze the current reading on the display. The 'HOLD' indicator will appear. Press the button again to release the hold function and resume live readings.
6.4. Recording (MIN/MAX/AVG)
Premere il tasto RICORDA button to enter recording mode. The display will show the maximum (MAX), minimum (MIN), and average (AVG) pressure values recorded since entering this mode. Short press the RICORDA button to cycle through MAX, MIN, and AVG values. Long press the RICORDA button for 5 seconds to exit recording mode.
Video 6.2: Oltreview of features including data recording and unit options on a digital manometer.
6.5. Differential Pressure Measurement
To measure differential pressure, connect the high-pressure source to the '+' port and the low-pressure source to the '-' port. Press the Differenza button. The display will show the pressure difference between the two inputs. Pressing the Differenza button again will reset the differential measurement to zero, allowing for quick offset correction.
6.6. Retroilluminazione
Premere il tasto Retroilluminazione button (often indicated by a light bulb icon) to turn the LCD backlight on or off. This feature enhances readability in dimly lit environments.
7. Applicazioni
The ZIBOO ET1013 Digital Manometer is suitable for a wide range of professional and industrial applications, including:
- HVAC system diagnostics and maintenance.
- Pneumatic control system testing.
- Medical equipment pressure verification.
- Gas appliance service and installation.
- Laboratory testing and research.
- Computer peripheral pressure monitoring.
- Optimizing production processes in various industries.

Figure 7.1: Diverse applications of the digital manometer in industrial and technical settings.
8. Specifiche
The following table outlines the technical specifications of the ZIBOO ET1013 Digital Manometer:
| Caratteristica | Descrizione |
|---|---|
| Display | Doppio LCD |
| Precisione | ±0.3%FSO (25°C) |
| Ripetibilità | ±0.2% (Max +/-0.5%FSO) |
| Linearità/Isteresi | ±0.29%FSO |
| Pressione massima | 10psi (HT-1890) |
| Tempo di risposta | 0.5 secondi tipici |
| Indicatore di batteria scarica | SÌ |
| Indicatore di fuori portata | Errore 1 |
| Indicatore di portata inferiore | Errore 2 |
| Condizioni operative | Da 32°F a 122°F (da 0 a 50°C) |
| Condizioni di conservazione | Da 14°F a 140°F (da -1 a 60°C) |
| Alimentazione elettrica | 1x 9V Battery (not included) or External 9VDC |
| Accessori standard | Custodia e tubi |
| Peso dell'articolo | 300 grammi |
| Dimensioni del pacco | Dimensioni: 20.6 x 10.9 x 5.69 cm |

Figure 8.1: Parametric indicators of the ZIBOO ET1013 Digital Manometer.
9. Manutenzione
To ensure the longevity and accuracy of your ZIBOO ET1013 Digital Manometer:
- Pulizia: Pulire il dispositivo con un panno morbido e asciutto. Non utilizzare detergenti abrasivi o solventi.
- Magazzinaggio: Store the manometer in its protective tool bag in a cool, dry place when not in use. Avoid areas with high humidity or extreme temperatures.
- Batteria: Replace the 9V battery when the low battery indicator appears on the display. Remove the battery if storing the device for extended periods to prevent leakage.
- Tubes and Adapters: Inspect pressure tubes and adapters regularly for wear, cracks, or blockages. Replace them if damaged to maintain measurement integrity.
10. Risoluzione Dei Problemi
If you encounter issues with your ZIBOO ET1013 Digital Manometer, refer to the following common problems and solutions:
- Nessun display/dispositivo non si accende: Check battery installation and ensure the battery has sufficient charge. Replace the 9V battery if necessary.
- Letture imprecise: Ensure pressure tubes are securely connected and free from kinks or leaks. Perform a zero-adjustment if needed (by pressing the DIF button to reset differential measurement). Verify the correct pressure unit is selected.
- 'Err.1' Displayed: Indicates an over-range condition. The measured pressure exceeds the device's maximum capacity. Reduce the applied pressure.
- 'Err.2' Displayed: Indicates an under-range condition. The measured pressure is below the device's minimum capacity.
- Indicatore di batteria scarica: Replace the 9V battery promptly to ensure continued accurate operation.
Per problemi persistenti non trattati qui, contattare l'assistenza clienti.
11. Garanzia e supporto
Specific warranty details and support contact information may vary by region and retailer. Please refer to the documentation provided with your purchase or contact the manufacturer directly for assistance.