KAIWEETS HT100s-R, KT301T

KAIWEETS HT100s-R VoltagManuale di istruzioni per il tester e il tester di presa GFCI KT301T

Models: HT100s-R, KT301T

1. Introduzione

This instruction manual provides essential information for the safe and proper operation of your KAIWEETS HT100s-R Non-Contact Voltage Tester and KAIWEETS KT301T GFCI Outlet Tester. Please read this manual thoroughly before use and retain it for future reference. These devices are designed to assist in electrical testing and ensure safety in various applications.

2. Informazioni sulla sicurezza

Always prioritize safety when working with electricity. Follow all local electrical codes and safety regulations. Do not use the testers if they appear damaged or are not functioning correctly. Always wear appropriate personal protective equipment (PPE).

3. KAIWEETS HT100s-R Non-Contact VoltageTester

3.1 Caratteristiche del prodotto

3.2 Setup and Battery Installation

The HT100s-R requires 2 AAA batteries (included). To install or replace batteries:

  1. Twist the tail cap counter-clockwise to open the battery compartment.
  2. Inserire due batterie AAA, rispettando la polarità corretta (+/-).
  3. Replace the tail cap and twist clockwise to secure it.

3.3 Istruzioni per l'uso

3.3.1 Accensione/spegnimento

Premere il pulsante di accensione () to turn the device on. Press and hold the power button to turn it off. The device will automatically power off after a period of inactivity to conserve battery.

3.3.2 Senza contatto voltage (NCV) Rilevamento

Place the tip of the tester near the conductor, outlet, or wire you wish to test. If AC voltage is detected, the tip will glow red, and an audible beep will sound. The frequency of the beeps and the percentage value on the screen will increase with higher voltage or closer proximity to the source.

KAIWEETS HT100s-R Non-Contact Voltage Tester che rileva il volumetage in an electrical outlet.

Image: The HT100s-R tester being used to detect voltage in an electrical outlet. The tip glows red, indicating voltage presenza.

3.3.3 Regolazione della sensibilità

The HT100s-R features two sensitivity modes:

The screen color indicates voltage livello: Rosso per alto volumetage/live wire, Verde per basso voltagfilo e/nullo.

KAIWEETS HT100s-R showing high and low sensitivity modes for null and live wire detection.

Image: Illustrations demonstrating the HT100s-R in both high and low sensitivity modes, indicating detection of null and live wires with corresponding visual and audible feedback.

3.3.4 Breakpoint Test

To perform a breakpoint test, move the tester along an insulated wire. The tester will indicate the presence of voltage up to the point of the break, helping to locate faults in cables.

KAIWEETS HT100s-R performing a breakpoint test on an insulated cable.

Image: The HT100s-R being used to perform a breakpoint test on an insulated electrical cable, illustrating its ability to detect breaks.

Torcia elettrica 3.3.5 LED

Press the flashlight button (💡) to turn on the integrated LED flashlight. This feature is useful for illuminating dimly lit work areas.

KAIWEETS HT100s-R with its LED flashlight illuminated in a dark electrical panel.

Image: The HT100s-R's bright LED flashlight illuminating a dark electrical panel, demonstrating its utility in low-light conditions.

4. Tester per prese GFCI KAIWEETS KT301T

4.1 Caratteristiche del prodotto

KAIWEETS KT301T GFCI Outlet Tester displaying its features and design.

Immagine: Un overview of the KAIWEETS KT301T GFCI Outlet Tester, highlighting its key features such as auto-hold, GFCI testing, LCD display, and low battery alert.

4.2 Setup and Battery Installation

The KT301T requires 2 AAA batteries (included). To install or replace batteries, open the battery compartment located on the back of the device, insert the batteries with correct polarity, and close the compartment securely.

4.3 Istruzioni per l'uso

4.3.1 Standard Outlet Testing

Plug the KT301T directly into a standard 3-prong outlet. The LCD display will immediately show the real-time voltage and the wiring condition. The bottom indicator lights will also provide a quick visual status (e.g., green for correct, orange for faults).

KAIWEETS KT301T testing both a standard outlet and a GFCI outlet.

Image: The KT301T in use, demonstrating its capability to test both standard electrical outlets and GFCI outlets, displaying voltage stato del cablaggio.

4.3.2 Test della presa GFCI

After plugging the KT301T into a GFCI outlet and observing the initial wiring status, press the TEST button. A correctly functioning GFCI outlet should trip, cutting power to the outlet. Press the RESET button on the GFCI outlet to restore power. If the GFCI does not trip, it indicates a fault.

4.3.3 Display LCD e indicatori

The 1.8-inch backlit LCD color screen provides clear readings of voltage and wiring status. Green indicates correct wiring, while orange indicates a fault. The bottom indicator lights offer additional visual cues, especially in dark environments.

KAIWEETS KT301T's backlit LCD color screen displaying voltage stato del cablaggio.

Image: A close-up of the KT301T's 1.8-inch backlit LCD color screen, showing a clear display of voltage and correct wiring status, suitable for various lighting conditions.

4.3.4 Auto-Hold Data

The auto-hold function captures and locks the test results on the screen for 5 minutes, allowing for easy viewing even in hard-to-reach locations or after removing the tester from the outlet.

KAIWEETS KT301T demonstrating the hands-free data hold function.

Image: The KT301T demonstrating its hands-free data hold feature, which locks the reading on the screen for convenient viewing after testing an outlet.

5. Manutenzione

6. Risoluzione Dei Problemi

ProblemaPossibile causaSoluzione
Il dispositivo non si accende.Batterie scariche o installate in modo errato.Sostituire le batterie assicurandosi che la polarità sia corretta.
HT100s-R gives inconsistent readings.Interference from nearby electrical fields; incorrect sensitivity mode.Move away from other electrical devices; switch to low sensitivity mode if appropriate.
KT301T shows a fault, but outlet seems to work.Hidden wiring fault (e.g., open ground, open neutral, reverse polarity).Consultare un elettricista qualificato per ispezionare il cablaggio.
KT301T GFCI test does not trip.Presa GFCI difettosa o cablaggio errato.Do not use the outlet. Have a qualified electrician inspect and repair/replace the GFCI outlet.

7. Specifiche

7.1 KAIWEETS HT100s-R Non-Contact VoltageTester

7.2 KAIWEETS KT301T GFCI Outlet Tester

8. Garanzia e assistenza clienti

KAIWEETS fornisce un Garanzia di 3 anno for these products. If you encounter any issues or have questions regarding the operation, maintenance, or troubleshooting of your HT100s-R Voltage Tester or KT301T GFCI Outlet Tester, please contact KAIWEETS customer support for professional assistance.

Per supporto, visita il sito ufficiale KAIWEETS websito o fare riferimento alle informazioni di contatto fornite sulla confezione del prodotto.

Documenti correlati - HT100s-R, KT301T

Preview Manuale utente del rilevatore di interruttori automatici digitali KAIWEETS KT301P
Manuale utente per il rilevatore di interruttori automatici digitali KAIWEETS KT301P, che descrive in dettaglio le sue caratteristiche, l'utilizzo e le specifiche per l'identificazione degli interruttori automatici e la verifica delle condizioni di cablaggio.
Preview Istruzioni e guida alla sicurezza del tester di presa Kaiweets KM117B
Guida completa per il tester di prese Kaiweets KM117B, che descrive in dettaglio le sue caratteristiche per il rilevamento di problemi di cablaggio, test GFCI e voltage misurazioni. Include avvertenze di sicurezza e specifiche tecniche.
Preview Manuale utente del rilevatore di interruttori automatici digitali KAIWEETS KT301P
Manuale utente per il localizzatore digitale di interruttori automatici KAIWEETS KT301P, che descrive in dettaglio le caratteristiche, gli avvisi di sicurezza, le istruzioni per l'uso e l'utilizzo degli accessori per individuare gli interruttori automatici e testare le condizioni del cablaggio.
Preview KAIWEETS VT200 Vol senza contattotagManuale operativo del tester
Manuale operativo ufficiale per il vol senza contatto KAIWEETS VT200tage tester, che fornisce istruzioni dettagliate sull'uso, sulle caratteristiche di sicurezza, sul prodottoview, specifiche tecniche e manutenzione.
Preview VT200 Vol senza contattotagManuale d'uso del rilevatore e
Manuale utente per il Kaiweets VT200 senza contatto voltage rilevatore, che copre le precauzioni di sicurezza, prodotto finitoview, funzionamento, sostituzione della batteria e specifiche generali.
Preview Manuale operativo del multimetro a penna intelligente KAIWEETS ST120
Questo manuale fornisce istruzioni dettagliate per il funzionamento del multimetro a penna intelligente KAIWEETS ST120, comprese le precauzioni di sicurezza, il prodottoview, funzioni di misurazione, specifiche tecniche e procedure di manutenzione.