1. Introduzione e oltreview
The SINOTIMER TM922 is a versatile dual-channel programmable digital timer switch designed for precise control of electrical equipment. It features two independent relay outputs, allowing simultaneous control of two separate devices or systems. With up to 8 ON/OFF programs per day and 15 combinations per week, this timer provides flexible scheduling options. Its accurate-to-the-second control ensures reliable operation according to preset programs, cycling weekly or daily from one second to 168 hours. Programs are saved by a battery backup in case of power failure, and the replaceable battery ensures long-term usage. The device is designed for DIN standard 35mm mounting, making it easy to install in DB boxes.

Figura 1: Fronte view of the SINOTIMER TM922 Digital Timer Switch.
2. Informazioni sulla sicurezza
Please read all instructions carefully before installation and operation. Incorrect installation or use can lead to electric shock, fire, or damage to the device. Ensure power is disconnected before any wiring or maintenance. This device should be installed by a qualified electrician in accordance with local electrical codes. Do not expose the device to moisture or extreme temperatures. Keep out of reach of children.
3. Caratteristiche del prodotto
- Dual Independent Relays: Two separate 16A outputs for controlling two distinct devices.
- Orari programmabili: Up to 8 ON/OFF programs per day, with 15 weekly combinations.
- Tempistica precisa: Accurate to the second, with cycles from 1 second to 168 hours.
- Backup della memoria: Built-in battery saves programs during power outages.
- Batteria sostituibile: Ensures long product life.
- Montaggio su guida DIN: Standard 35mm design for easy installation in electrical panels.
- Ampio display LCD: Clear blue backlight for easy readability.

Figure 2: Close-up of the TM922's LCD display and control buttons.
4. Contenuto della confezione
- SINOTIMER TM922 Digital Timer Switch
- One screwdriver
- Manuale dell'utente (questo documento)
5. Specifiche
| Attributo | Valore |
|---|---|
| Dimensioni del prodotto | 3.54 x 1.42 x 2.68 pollici |
| Peso dell'articolo | 5.9 once |
| Ingresso volumetage | 85-265 V CA |
| Relè di uscita | Two independent 16A outputs |
| Materiale | Plastica |
| Colore | Bianco |
| Numero di impostazioni | 23 (programmi) |
6. Configurazione e installazione
6.1 Montaggio su guida DIN
The TM922 is designed for standard 35mm DIN rail mounting. To install, align the timer with the DIN rail and press firmly until it clicks into place. Ensure it is securely fastened.

Figura 3: lato view che illustra il meccanismo di montaggio su guida DIN.
6.2 Schema elettrico
AVVERTIMENTO: Disconnect all power before wiring. Wiring should be performed by a qualified professional.
The TM922 features terminals for power input (L, N) and two independent relay outputs (C1, C2). Each output has common (C), normally open (NO), and normally closed (NC) contacts. Refer to the labels on the device for precise terminal identification.
- Potenza in ingresso: Connect your 85-265VAC power supply to the 'L' (Live) and 'N' (Neutral) terminals.
- Channel 1 Output (C1): Connect your first load to the C1 terminals. For normally open operation, connect the load between the common (C1-4) and normally open (C1-5) terminals. For normally closed operation, connect between common (C1-4) and normally closed (C1-6) terminals.
- Channel 2 Output (C2): Connect your second load to the C2 terminals. For normally open operation, connect the load between the common (C2-1) and normally open (C2-2) terminals. For normally closed operation, connect between common (C2-1) and normally closed (C2-3) terminals.

Figure 4: Wiring terminals for power input and dual relay outputs.
7. Istruzioni per l'uso
7.1 Funzioni dei pulsanti

Figure 5: Control button functions for the TM922.
- MENU: Unlock/Lock buttons, Enter program settings.
- ▲ (Freccia su): Increase value, Navigate up.
- ▼ (freccia giù): Decrease value, Navigate down.
- OK: Select, Confirm settings.
- Res (Reimposta): Channel selection, Sleep mode, Remove programs. (Requires a pointed object like a pen or the provided screwdriver).
7.2 Locking/Unlocking the Timer
To prevent accidental changes, the timer can be locked. Press and hold the MENU button for more than 3 seconds to lock or unlock the timer. The 'LOCK' indicator on the display will show the current status.
7.3 Impostazione dell'ora corrente
- Ensure the timer is unlocked.
- Premere il tasto OK button repeatedly to cycle through and select the minute, hour, second, and day of the week.
- Utilizzare il ▲ E ▼ buttons to adjust the selected number.
- Premere OK per confermare ogni impostazione.
7.4 Manual Control (Working Status)
To manually override the programmed settings for a channel, press the MENU E ▲ buttons together. This will cycle the working status through: ON, ON AUTO, OFF, AUTO OFF. The current status will be displayed (e.g., F1 ON, F2 OFF).
7.5 Switching Channels (F1/F2)
To switch between Channel 1 (F1) and Channel 2 (F2) for programming or manual control, press the recessed Ris. button using a pointed object. The display will show 'F1' or 'F2' to indicate the active channel.
7.6 Programmazione dei cicli di accensione/spegnimento
The TM922 supports up to 8 ON/OFF programs for each channel (F1 and F2), totaling 16 ON/OFF events per channel. Each program can be set for specific days of the week.
- Ensure the timer is unlocked.
- Select the desired channel (F1 or F2) by pressing the Ris. pulsante.
- Premere il tasto MENU button to enter the program setting mode. The display will show '1 ON' (for the first ON program).
- Premere OK to select the time setting for '1 ON'. Use ▲ E ▼ to adjust the hour, minute, and second. Press OK dopo ogni regolazione.
- After setting the time, you can select the days of the week for this program. Use ▲ E ▼ to cycle through various day combinations (e.g., Mo Tu We Th Fr Sa Su, Mo-Fr, Sa Su, etc.). Press OK per confermare.
- The display will then show '1 OFF'. Repeat steps 4 and 5 to set the OFF time and days for the first program.
- Continua a premere MENU to cycle through '2 ON', '2 OFF', up to '8 ON', '8 OFF' for the current channel, setting each as needed.
- Once all programs are set, press and hold MENU to exit programming mode and return to the main clock display.
Video 1: Official SINOTIMER guide on setting up the TM922's channels and programs.
8. Manutenzione
8.1 Sostituzione della batteria
The TM922 uses a replaceable battery to maintain program settings during power outages. If the display becomes dim or settings are frequently lost, the battery may need replacement. Refer to the device's internal compartment for battery type and replacement instructions. Ensure power is disconnected before replacing the battery.
8.2 Pulizia
Clean the device with a soft, dry cloth. Do not use abrasive cleaners or solvents, as these can damage the casing o display.
9. Risoluzione Dei Problemi
- Il timer non commuta:
- Check if the timer is in 'AUTO ON' or 'AUTO OFF' mode. Use manual control to switch to 'AUTO ON' for programmed operation.
- Verify that the ON/OFF programs are correctly set for the desired times and days.
- Assicurarsi che il dispositivo sia alimentato.
- Impostazioni perse dopo lo spegnimentotage:
- The internal backup battery may be depleted or faulty. Replace the battery.
- Pulsanti non reattivi:
- Ensure the timer is unlocked (press and hold MENU for 3 seconds).
- If the 'Res' button is stuck, gently try to release it. Avoid pressing too hard.
- Il display è scuro o vuoto:
- Controllare l'alimentazione elettrica.
- Replace the internal backup battery.
10. Garanzia e supporto
This SINOTIMER product comes with a standard manufacturer's warranty. For specific warranty details, please refer to the documentation included with your purchase or contact SINOTIMER customer support. For technical assistance, troubleshooting, or spare parts, please visit the official SINOTIMER webo contattare il servizio clienti. Conservare la ricevuta d'acquisto per eventuali reclami in garanzia.
Visitare il Negozio SINOTIMER per ulteriori informazioni.