Errori di runtime del pannello touch
The touch panel may encounter runtime errors that could affect communication with connected PLCs. Below are the common runtime errors:
Errore n. RTE-001
Messaggio di errore: Spazio di memoria insufficiente in %Device%
Causa: The size of the destination memory is insufficient to store the data.
Errore n. RTE-002
Messaggio di errore: Errore registro. Impossibile trovare %Device%
Causa: No device is available or the device is defective.
Errore n. RTE-003
Messaggio di errore: Registro non riuscito. Impossibile scrivere file -%file%
Causa: Logging the data failed due to issues like memory write protection being enabled.
Errore n. RTE-004
Messaggio di errore: La memoria cache del registro è piena
Causa: Il buffer del registro dati nella memoria SRAM è pieno.
Errori di handshake
Handshake errors occur when communication timeouts or connection issues arise. Below are some common handshake errors:
Introduzione
I touch panel C-more dispongono di una diagnostica integrata nel sistema operativo che monitora varie funzioni di runtime e visualizza un messaggio di errore sul display del pannello, indicando che si è verificato un errore specifico e cosa rappresenta. Il/I messaggio/i di errore vengono visualizzati nell'area in alto a sinistra dello schermo. Gli errori di runtime vengono inoltre registrati nel registro errori del pannello, nella scheda Informazioni nelle schermate di configurazione del sistema. Il codice del registro errori, ad esempioample RTE-004, identifies the error on the System Screen – Error tab and in the error log. See Chapter 5: System Setup Screens for additional details. The tables that follow show the possible Runtime Errors.
The user can include in their touch panel project the use of this diagnostic information by using the system tag nome SYS ERR ERRORCODE per controllare le schermate visualizzate, i messaggi operatore, ecc. e anche per comunicare informazioni di errore al PLC o al dispositivo di controllo. Se si verifica un errore di runtime, il sistema SYS ERR ERRORCODE tag conterrà il valore numerico mostrato sotto Tag Code Error Value.
Per esempioample, se il progetto del pannello è configurato per registrare su USB e nessuna unità flash USB è installata nel pannello, il pannello visualizzerà "RTE-004 La memoria buffer di registro è piena" e il sistema SYS ERR ERRORCODE tag will contain the value 2004. The value of the last runtime error detected will remain in the SYS ERR ERRORCODE.
If you have difficulty determining the cause of the error, refer to Chapter 8: Troubleshooting for additional help or contact our technical support group at 770- 844-4200

Errori di runtime
La tabella seguente include tutti i codici di errore e i messaggi di errore che il pannello visualizzerà se viene rilevata la causa elencata. Tutti questi errori riguardano problemi che potrebbero verificarsi nella comunicazione tra il pannello e il PLC collegato. Si prega di notare che non tutti gli errori del pannello sono utilizzati con ogni tipo di PLC collegabile al pannello.




Serie finitaview
C-more CM5 Series Touch Panels
- Compatible with EA9 project versions 6.73 or newer
- Analog touch screen
- 16.7-million colors LCD for enhanced graphics
- Screen resolutions up to 1920 X 1080 pixel
- FTP client/server
- Client di posta elettronica
- Webserver (Secure HTTPs)
- cliente MQTT
- User configurable LED on the front of the panel
- Project simulation
- Up to (2) Ethernet ports
- Up to 3 serial ports, RS-232C, RS422/485
- Up to (4) USB-A ports for logging, backups,and HID devices
- Programming via USB or Ethernet
- Thousands of built-in symbols and Windows fonts
- Network time server/client
- JPEG and JPG graphic object support
- Ethernet Remote Access
- Customizable label on the front of the panel
- 2-year warranty from date of purchase

C-more 7” TFT Color Touch Panel
C-more CM5 series touch screen HMI, 7.0-inch color TFT LCD, 16.7M colors, 800 x 480 pixel WVGA screen resolution, 800 MHz CPU, 12–24 VDC powered, NEMA 4/4X, IP65 (when mounted correctly; for indoor use only). Includes (1) Ethernet, (2) serial and (2) USB ports and (1) memory card slot. Compatible with CM5-PGMSW programming software v8.0 or later.


Caratteristiche
- 7.0” diagonal color TFT (thin film transistor) LCD display with 16.7M colors
- Risoluzione 800 x 480 pixel
- 310 nits display brightness
- 50,000 hour average backlight half-life
- Analog resistive (1024 X 1024) touch screen allowing unlimited touch areas
- (1) USB port B (program/download)
- (1) USB port A (USB device options)
- Ethernet 10/100 Base-T port (program/download & PLC communication)
- Ethernet Remote Access
- Serial PLC interface (RS-232C/422/485)
- Horizontal or portrait mounting
- One built-in SD memory card slot
- 12–24 VDC powered
- 45MB project memory
- La registrazione dei dati
- 0 to 50°C [32 to 122°F] operating temperature range
- NEMA 4/4X, IP65 compliant when mounted correctly, indoor use only
- Slim design saves enclosure space
- Works with Remote HMI Mobile App
Porte di comunicazione

Dimensioni del ritaglio

C-more Selection Guide & Specifications






Protocolli di comunicazione


Cavi di comunicazione


Nota – Refer to the appropriate User Manual for specific cable pinouts, communication protocols and connection instructions.
Accessori
C-more touch panels can be enhanced with the accessories below:

Accessory Locations
CM5-T7W, CM5-T10W, CM5-T12W, CM5-T15W, CM5-T22W

Schede SD
EA-SD-CARD
MSD-SLC16G

SD memory cards for non-volatile storage, 2GB or 16GB industrial grade. High operating temperature make EA-SD-CARD and MSD-SLC16G suitable for data logging in industrial applications. These cards are recommended for C-more CM5 series.
EA-SD-CARD and MSD-SLC16G utilize SLC technology so they are the fastest and most reliable option for writing and storing data. If logged data is saved to external memory, AutomationDirect recommends using EA-SD-CARD. and MSDSLC16G.
SLC Flash has the longest lifespan of flash types and can operate in a broader temperature range than other types.
EA-SD-CARD and MSD-SLC16G with SLC Flash memory is recommended for industrial workloads that require heavy read/write cycles.

Chiavetta USB
USB-FLASH

USB-FLASH sold by AutomationDirect has been tested with C-more HMIs and is Hi-Speed USB 2.0 certified. The MSD-SLC16G is the best option for logging data, but the USB-FLASH is a high-quality flash drive perfect for transferring log files, capturing screens, backing up and restoring projects and storing images for the Image Viewer object.
D-SUB 15-pin to Terminal Block Adapter – Right Angle
The EA-COMCON-3 adapter plugs into the 15-pin serial port on the rear of a panel to allow wire terminal connections for an RS-422/RS-485 communication cable. For use with C-more Micro EA1 series 4in and 6in HMIs, C-more Micro EA3 series 3in, 4in, and 6in HMIs, C-more EA9 series 6in and 7in HMIs, C-more CM5 series 4in HMI.
EA-COMCON-3

D-SUB 15-pin to Terminal Block Adapter – Straight Through
The EA-COMCON-3A adapter plugs into the 15-pin serial port on the rear of a panel to allow wire terminal connections for an RS-422/RS-485 communication cable. For use with C-more Micro EA1 series 3in with EA1-MG-SP1, C-more Micro EA3 series 8in and 10in HMIs, C-more EA9 series 8in, 10in, 12in and 15in HMIs, C-more CM5 series Headless, 7in, 10in, 12in, 15in,and 22in HMIs. The EA-COMCON-3A is not UL recognized or listed.
EA-COMCON-3A


Non-glare Screen Covers (in packages of 3)
The non-glare screen covers are protective overlays used to protect the touch screen while helping to reduce the glare from external light sources.
Numeri di parte: HMI-4W-COV, HMI-7W-COV, HMI-10W-COV, HMI-12W-COV, HMI-15W-COV, HMI-22W-COV

HMI-4W-COV $44.50
HMI-7W-COV $51.00
HMI-10W-COV $59.00
HMI-12W-COV $43.00
HMI-15W-COV $49.00
HMI-22W-COV $73.00

Installazione

NOTA: The Protective Cover ships with a thin protective sheet on the face of the cover that needs to be carefully removed. If your panel is not clear, the protective sheet may not have been removed.
Parti di ricambio
These replacement parts can be used to replace damaged, worn or lost C-more components.
Replacement parts at a glance:


Software di programmazione
CM5-PGMSW -FREE Download!
C-more Programming Software can be downloaded at no charge or a USB version may be purchased by ordering CM5-PGMSW. The software requires a USB port or Ethernet connection* on your PC to connect to the C-more panel. Software Help Files are included in the download. This software programs all the C-more panels.
CM5-PGMSW USB Flash Drive

Caratteristiche del software
- Over 50 objects including 16 pen trends, switches, PID trend faceplate, PID bar graph
- Event Manager allows for logging and notifications
- Language support for objects in German, French, Italian, Spanish, Chinese and Japanese Characters
- Project simulator
- Bitmap animation
- E-mail messaging
- Built-in FTP server / Webserver (Secure HTTPs)
- Popup windows
- Data logging to USB/SD flash drive
- USB 2.0 Type B port for programming
- Historical alarms with time and date stamp along with alarm frequency reporting
- Supports simultaneous communication to multiple brands of PLC/PACs
- Mouse and keyboard support within the project
- Remote HMI feature with smart phone / tablet / PC
- Garanzia di 2 anni
Requisiti di sistema del computer
CM5-PGMSW will run on PCs that meet the following requirements:
- Windows OS: 8: 32 & 64 bit, 8.1: 32 & 64 bit, 10, 11
- 2GB of available memory
- 1GB spazio su disco rigido
- Available Ethernet or USB port
http://www.automationdirect.com
Domande frequenti
How can I resolve a Not enough Memory Space error?
To resolve this error, consider optimizing memory usage on the device or connecting to a device with larger memory capacity.
What should I do if I encounter a Handshake Timeout Error?
Check your network connection, ensure proper settings for Recipe or Numeric Entry Objects, and try restarting the communication process.
How can I troubleshoot an Email Connection Error?
Verify the email server settings, check network connectivity,and ensure correct email address configuration on the touch panel.
Documenti / Risorse
![]() |
Schermo tattile LCD TFT a colori serie CM5 di AutomationDirect [pdf] Manuale d'uso CM5-RHMI-USER-M, Schermo tattile LCD TFT a colori serie CM5, Serie CM5, Schermo tattile LCD TFT a colori, Schermo tattile LCD, Schermo tattile |