The Xiaolei HSD-BLE motion sensor detects human movement and ambient light changes using Bluetooth 5.0 SIG Mesh networking. It supports OTA updates and, when paired with a smart gateway and connected to the app, can trigger local or cloud automation scenes.
Specifiche tecniche
| Modello | HSD-BLE |
| Tipo senza fili | Rete SIG Bluetooth 5.0 |
| Volume di eserciziotage | 3.0Vdc (Lithium Battery CR123A) |
| Altezza di montaggio | ≤ 4 metri |
| Angolo di rilevamento | ≤ 120° |
| Ambiente di lavoro | Temperatura ambiente: da 0°C a 40°C |
| Peso netto | 115 grammi |
| Dimensioni | 90 × 90 × 36 mm (L × P × A) |
| Housing Geometry (mm) | Outer diameter: 90; Sensor lens circular area: 35; Rear mounting section diameter: 75; Total depth/thickness: 36; Mounting hole spacing: 46; Hole diameter: φ 3.7 |
- Coverage guidance (lab-derived): Maximum detection radius varies by ceiling height (examples shown in manual): 2.5 m→3.0 m; 3.0 m→3.5 m; 3.5 m→4.0 m; 4.0 m→5.5 m.
- Nota: Data is derived from laboratory tests; actual values may vary by usage scenario.
Impostazione e utilizzo
- Install (pair first): Complete pairing via the App before installation.
- Mount the sensor:
- Adhesive tape: Peel the tape and stick the sensor on a wall or flat table surface.
- Screw mounting: Rotate the bottom cover counterclockwise, secure the cover to the wall/table with screws, then rotate clockwise to reattach the sensor unit.
- Verify indicator response: Wave your hand at the ideal trigger position and confirm the red indicator flashes. If not, adjust installation angle/position and test again.
- App installation and configuration: Register an account in the App, then on the [Room] interface tap + to add a device and select Sensor – Human Body Sensor HSD-BLE.
- Automation setup (optional): Ensure a smart gateway is added to the family network, then create an automation on the [Smart] by selecting local or cloud execution mode and setting trigger conditions and actions.
- Method 1: Manual Reset Button Press and hold the sensor button for 15 seconds until the indicator flashes rapidly, then release. Short press the knob/button 3 times within 3 seconds. The indicator will blink, indicating the device has successfully restored to factory settings.
- Method 2: Battery Reinsertion. Remove the battery and wait for 20 seconds. Hold down the sensor button, then reinstall the battery. The indicator will flash rapidly 5 times, indicating a successful factory reset.
- Method 3: Via App Open the L-Home App, locate the device, and open its settings Ensure your mobile phone has Bluetooth enabled and is placed close to the sensor. Quick short-press the physical button on the sensor 5 times within 2 seconds. The indicator will flash 3 times to activate the device. Tap the “Delete Device” button on the App. Once the interface displays “Deleted successfully”, the device has been reset.
Attentions & Safety Guidelines
- For optimal performance, install this product in an open area. Do not place the sensor near or behind metal surfaces, tall cabinets, shelves, hanging fixtures, ceiling fans, or similar objects. Keep the area around the device free of metal obstructions. Since the sensor cannot penetrate glass, do not install it facing or on glass surfaces such as patio doors or green houses.
- Hot objects and moving air currents may affect sensor performance and reduce motion detection sensitivity. For reliable operation, install the sensor at least 1.2 meters away from air conditioning vents, heating systems, halogen lamps, and incandescent light bulbs.
- Devices emitting radio frequency (RF) energy may interfere with wireless performance. Install the sensor at least 1.2 meters away from RF-emitting electronics such as microwave ovens and wireless routers.
- When installing multiple sensors in the same area, maintain a distance of at least 0.3 meters between each unit.
- Do not incinerate the device or battery. Keep away from extreme heat sources.
- This product is not rated for damp, wet, or high-humidity environments.
- Do not disassemble, modify, or attempt to repair this product yourself, as doing so will void the warranty coverage.
Risoluzione dei problemi
- If the App fails to find the device:
- Ensure the device is powered on normally and is fully activated.
- Keep your mobile phone close to the device (recommended distance under 15 meters).
- Verify the device has not already been bound to another account; if it has, perform a manual factory reset.
- If the indicator does not flash during the response test: Adjust the installation angle/position and test again (wave your hand at the ideal trigger position).
Diagramma del sistema

Introduzione al prodotto
This motion sensor features the Bluetooth 5.0 SIG Mesh highly reliable networking protocol, enabling accurate detection of human movement and ambient light changes. It supports OTA updates for easy long-term maintenance. When paired with a smart gateway and connected to the app, it can flexibly trigger local and cloud-based automation scenes, enabling seamless smart linkage throughout the home
Contenuto della confezione

Specifiche tecniche
| Modello | HSD-BLE |
| Tipo senza fili | Rete SIG Bluetooth 5.0 |
| Volume di eserciziotage | 3.0Vdc(Lithium Battery CR123A) |
| Altezza di montaggio | ≤4M |
| Angolo di rilevamento | ≤120° |
| Ambiente di lavoro | 0℃~40℃ |
| Peso netto | 115g |
| Dimensioni | 90 × 90 × 36 mm (L × P × A) |
Dimensioni del prodotto
Sostituzione della batteria
- Rotate counterclockwise to remove the bottom cover
- Sostituire la batteria
- Rotate clockwise to tighten the bottom cover.
Detection Angle and Range
Sensor Coverage Diagram (Sensor installed at the center of the room)
| Ceiling Height H | Maximum Detection Radius R |
| 2.5 milioni | 3M |
| 2.7 milioni | 3.5 milioni |
| 3M | 4M |
| 4M | 5.5 milioni |
Note: Multiple sensors can be added to expand the coverage. The maximum number of sensors allowed in the system depends on the specifications of the receiving device. * Data is derived from laboratory tests. Actual values may vary depending on the usage scenario; please refer to real-world performance
Metodo di installazione
(Note: Please complete pairing via the APP before installation.)
- Method 1: Peel off the tape and stick it on the wall or table.

- Method 2: Rotate to open the bottom cover, secure the cover to the wall or table with screws, then reattach the sensor.

Precauzioni di installazione
During installation, please refer to “Detection Angle and Range.” on After installation, test the response between the user and the sensor as follows: Wave your hand at the ideal trigger position of the sensor and check if the red indicator flashes.If not, adjust the position and test again.
Istruzioni per l'uso dell'app
- Registra un account
Scansiona il codice QR qui sotto con il tuo cellulare e segui le istruzioni per completare l'installazione dell'app.
- 2. Configurare
After a new user creates a family on the APP, click “+” in the upper right corner of the 【Room】interface to add a device. Select “Sensor – Human Body Sensor HSD-BLE” in the list of added devices and follow the on-screen prompts to complete the addition.
- 3. Automazione
Make sure that a smart gateway, such as SP-GW-12S has been added to the family. Select “Automation” in the【Smart】 and click “+” to create automation. You can choose local/cloud execution mode, and set trigger conditions and execution actions. When the set trigger conditions are met, a series of device actions are automatically triggered to achieve remote linkage.
Ripristino delle impostazioni di fabbrica
- Method 1: Press and hold the sensor button for 15 seconds until the indicator flashes rapidly, then release. Short press the knob 3 times within 3 seconds. The indicator will blink, indicating the device has been restored to factory settings.
- Method 2: Remove the battery and wait for 20 seconds. Hold down the sensor button, reinstall the battery. The indicator will flash rapidly 5 times, indicating the device has been restored to factory settings.
- Method 3: Open the L-Home APP, locate the device and enter its settings . Connect your phone to Bluetooth and keep the device near the phone. Quickly short-press the button 5 times within 2 seconds. The indicator will flash 3 times to activate the device. Then tap the “Delete Device” button. When the interface shows “Deleted successfully”, the device has been restored to factory settings.

Attenzioni
- For optimal performance, use this product in an open area. Do not install the sensor near or behind metal surfaces, tall cabinets, shelves, hanging fixtures, ceiling fans, or similar objects. Keep the area around the device free of metal obstructions. Since the sensor cannot penetrate glass, do not install it on glass surfaces such as patio doors or shower doors. Hot objects and moving air may affect sensor performance and reduce motion detection sensitivity. For reliable operation, install the sensor at least 1.2 meters away from air conditioning vents, halogen lamps, and incandescent light bulbs located below ceiling lines.
- Devices emitting radio frequency (RF) energy may interfere with sensor performance. For reliable operation, install the sensor at least 1.2 meters away from radio-emitting devices such as microwave ovens and wireless routers.
- When installing multiple sensors, maintain a distance of more than 0.3 meters between each unit.
- Do not incinerate. Keep away from heat sources.
- Not for use in damp o ambienti umidi.
- Do not disassemble the product by yourself, as this will void the warranty.
- Do not open, modify, repair or service this product, otherwise the warranty will be invalidated.
Accordo di garanzia
- Termini di garanzia dalla data di consegna: 2 anni.
- Free repair or replacement services for quality problems are provided within the warranty periods.
Esclusioni di garanzia di seguito:
Le seguenti condizioni non rientrano nell'ambito di garanzia dei servizi di riparazione o sostituzione gratuiti:
- Oltre i periodi di garanzia.
- Qualsiasi danno artificiale causato da alto voltage, sovraccarico o operazioni improprie. Prodotti con gravi danni fisici.
- Danni causati da calamità naturali e forza maggiore.
- Le etichette di garanzia e i codici a barre sono stati danneggiati.
- Nessun contratto firmato da LTECH.
- La riparazione o la sostituzione fornita è l'unico rimedio per i clienti. LTECH non è responsabile per alcun danno incidentale o consequenziale a meno che non sia previsto dalla legge.
- LTECH has the right to amend or adjust the terms of this warranty, and release in written form shall prevail. This manual is subject to changes without further notice. Product functions depend on the goods. Please feel free to contact our official distributors if you have any question.
ULTERIORI INFORMAZIONI
Documenti / Risorse
![]() | HSD-BLE Motion Sensor |
Riferimenti
- ltech.cn/SuperPanel-app.htmlwww.ltech.cn
- xiaolei.cnwww.xiaolei.cn
- xiaolei.com.cnwww.xiaolei.com.cn
- Manuale d'usomanual.tools