SoliTek SOLID Series Solar Modules

Istruzioni per l'uso
- Read this guide entirely before installation.
- This document provides minimum requirements and recommendations for safe and successful installation of SoliTek PV modules and is necessary to retain compliance with IEC 61215, IEC 61730, and UL 61730 standards.
- This guide provides basic information on JSC SoliTek Cells SOLID series photovoltaic modules, including their installation and safe handling.
- All instructions should be read and understood before attempting installation. Contact your dealer or JSC SoliTek Cells for further information if needed.
- This documentation refers to the PV modules themselves and is not a comprehensive installation manual for personnel not specifically trained in PV modules.
- It serves as a general but strictly mandatory reference for the installer. Infringement or inaccurate observance of any clause in this documentation voids the warranty.
- The installer must understand and follow all applicable local, state, and federal regulations and standards for building construction, electrical design, fire, and safety.
- Check with local authorities for permitting requirements before installing or maintaining PV modules, and become familiar with mechanical and electrical requirements for photovoltaic systems.
- La mancata osservanza delle istruzioni contenute in questa guida potrebbe danneggiare i componenti del sistema, mettere in pericolo il personale, danneggiare la proprietà o invalidare la garanzia del pannello.
- Rooftop PV systems should only be installed on dwellings formally analyzed for structural integrity and confirmed to be capable of handling the additional weighted load of PV system components (including PV modules) by a certified building specialist or engineer.
REQUISITI GENERALI
- Si prega di leggere interamente questa guida prima dell'installazione.
- Lo scopo di questo documento è fornire i requisiti minimi e le raccomandazioni per un'installazione sicura e corretta dei moduli fotovoltaici SoliTek.
- Il presente documento contiene inoltre i requisiti necessari per mantenere la conformità dei moduli fotovoltaici SoliTek agli standard IEC 61215, IEC 61730 e UL 61730.
- Questa guida contiene le informazioni di base relative ai moduli fotovoltaici della serie SOLID JSC “SoliTek Cells”, alla loro installazione e manipolazione sicura. Tutte le istruzioni devono essere lette e comprese prima di tentare l'installazione. In caso di domande, contattare il proprio rivenditore o JSC "SoliTek Cells" per ulteriori informazioni.
- This documentation refers to the PV-modules themselves and is not meant to be a complete installation manual for personnel not specifically trained to PV-modules.
- It serves as a general but strictly mandatory reference for the Installer.
- La violazione o l'osservanza non accurata di una qualsiasi clausola della presente documentazione invalida la garanzia.
- L'installatore deve comprendere e seguire tutti i regolamenti e gli standard locali, statali e federali applicabili per la costruzione di edifici, la progettazione elettrica, antincendio e sicurezza e deve verificare con le autorità locali per determinare i requisiti di autorizzazione applicabili prima di tentare di installare o mantenere i moduli fotovoltaici e dovrebbe acquisire familiarità con i requisiti meccanici ed elettrici per gli impianti fotovoltaici.
- Il mancato rispetto delle istruzioni contenute in questa guida può danneggiare i componenti del sistema, mettere in pericolo il personale, danneggiare la proprietà o invalidare la garanzia del pannello.
- I sistemi fotovoltaici sul tetto dovrebbero essere installati solo su abitazioni che sono state formalmente analizzate per l'integrità strutturale e confermate come in grado di gestire il carico ponderato aggiuntivo dei componenti del sistema fotovoltaico, compresi i moduli fotovoltaici, da uno specialista o un ingegnere edile certificato.
- For your safety, do not attempt to work on a rooftop until safety precautions have been identified and taken, including, without limitation fall protection measures, ladders or stairways, and personal protective equipment (PPE).
- For your safety, do not install or handle PV modules under adverse conditions, including, without limitation strong or gusty winds, and wet or frosted roof surfaces.
- La costruzione del modulo fotovoltaico a piastra piatta è costituita da un assemblaggio laminato di celle solari incapsulate all'interno di un materiale isolante all'interno di due lastre di vetro.
- Conservare questa documentazione in un luogo sicuro per future consultazioni.
- Non tentare di smontare il modulo e non rimuovere eventuali targhette o componenti attaccati! Ciò invaliderà la garanzia.
Gestione e applicazione
GESTIONE
- SoliTek PV modules must be transported in the supplied packaging only and kept in the packaging until they are ready to be installed.
- Protect pallets against movement and exposure to damage during transportation. Secure pallets from falling over.
- Non superare l'altezza massima dei pallet da impilare, come indicato sulla confezione del pallet.
- Store pallets in a cool and dry location until the PV modules are ready to be unpackaged.
- SoliTek PV modules are heavy and should be handled with care. Never use the junction box or cables as a grip.
- Do not exert mechanical stress on the cables.
- Never step on PV modules or drop or place heavy objects on them.
- Be careful when placing PV modules on hard surfaces and secure them from falling.
- Broken glass can result in personal injury. PV modules with broken glass cannot be repaired and must not be used.
- Broken or damaged PV modules must be handled carefully and disposed of properly.
APPLICAZIONE
Restrizioni
- SoliTek PV modules must be mounted on appropriate mounting structures positioned on suitable buildings, the ground, or other structures suitable for PV modules (e.g. carports, building facades or PV trackers).
- PV modules must not be mounted on moving vehicles of any kind. Modules must not be installed in locations where they could be submerged in water.
- Do not install modules above 2000 m (6561 ft) altitude above sea level
- La luce concentrata artificialmente non deve essere diretta sui moduli fotovoltaici SoliTek.
Raccomandazioni
- SoliTek consiglia di montare i moduli fotovoltaici con un angolo di inclinazione minimo di 10 gradi per consentire un'adeguata autopulizia dalla pioggia.
- L'ombreggiamento parziale o completo di uno o più moduli fotovoltaici può ridurre significativamente le prestazioni del sistema.
- SoliTek consiglia di ridurre al minimo la quantità di ombra durante tutto l'anno per aumentare la quantità di energia prodotta dai moduli fotovoltaici.
- Sistema alto voltages could be induced in the event of an indirect lightning strike, which could cause damage to PV system components.
- The open area of wire loops should be minimized in order to reduce the risk of lightning-induced voltage picchi.
- Una migliore ventilazione dei moduli e cavi di collegamento più corti aumentano la produzione di energia elettrica.
Per i moduli bifacciali:
- Si consiglia di aumentare l'altezza del pannello fotovoltaico da terra in modo che più luce possa viaggiare sotto il modulo e quindi riflettersi
- Il guadagno bifacciale aumenta significativamente se i moduli vengono installati sopra superfici bianche (alto valore di albedo) che riflettono la luce.
Installazione elettrica
SICUREZZA
- I moduli fotovoltaici possono produrre corrente e voltage quando esposto a luce di qualsiasi intensità. La corrente elettrica aumenta con una maggiore intensità luminosa. DC voltage di 50 Volt o superiore è potenzialmente letale. Il contatto con i circuiti sotto tensione di un sistema fotovoltaico funzionante in condizioni di luce può provocare scosse elettriche letali.
- Disattivare i moduli fotovoltaici rimuovendoli completamente dalla luce o coprendone la superficie frontale con un materiale opaco. Rispettare le norme di sicurezza per le apparecchiature elettriche sotto tensione quando si lavora con moduli esposti alla luce. Utilizzare utensili isolati e non indossare gioielli metallici durante la manipolazione dei moduli fotovoltaici.
- Per evitare archi elettrici e scosse elettriche, non scollegare i collegamenti elettrici sotto carico. Anche i collegamenti difettosi possono causare archi elettrici e scosse elettriche. Mantenere i connettori asciutti e puliti e assicurarsi che siano in condizioni di funzionamento adeguate. Non inserire mai oggetti metallici nei connettori o modificarli in alcun modo per fissare un collegamento elettrico.
- Do not touch or handle PV modules with broken glass unless the PV modules are first disconnected, and you are wearing proper PPE. Avoid handling PV modules when they are wet unless cleaning the PV modules as directed in this manual. Never touch electrical and wet connections without protecting yourself with insulated gloves.
- The modules are qualified for Class II protection against electrical shock, in accordance with clause 4 of IEC 61730-1:2016, which can be used in systems operating at > 50 V DC or >240 W, where general contact access is anticipated and modules qualified for safety through UL 61730 within this application class are considered to meet the requirements of Safety Class II.
- L'installazione di impianti solari fotovoltaici richiede competenze e conoscenze specialistiche. Deve essere eseguita solo da personale qualificato e appositamente istruito. L'installatore si assume tutti i rischi di lesioni, compreso il rischio di scosse elettriche.
- Utilizzare solo apparecchiature, connettori, cablaggio e hardware di montaggio specificamente progettati per l'uso in un impianto fotovoltaico.
- Before any manipulation at an installed PV plant, switch it off first on the AC-side, and then on the DC side of the inverter or the charge controller.
- Quando si scollegano i cavi collegati a un modulo fotovoltaico esposto alla luce, potrebbe verificarsi un arco elettrico. Gli archi elettrici possono causare ustioni, incendi o creare in altro modo problemi di sicurezza (fino a scosse elettriche letali).
- Verificare il volume rimanentetage before starting and observe the local safety-relevant regulations for such working conditions.
- In condizioni normali, un modulo fotovoltaico può produrre più corrente e/o voltage (qui: 30 V CC) rispetto a quanto riportato in condizioni di prova standard.
- Contatto con un DC voltage di 30 V o più è potenzialmente pericoloso. Prestare attenzione durante il cablaggio o la manipolazione dei moduli esposti alla luce solare.
- Collegare solo moduli con la stessa corrente di uscita nominale in serie. Se i moduli sono collegati in serie, il volume totaletage è uguale alla somma del singolo modulo voltages.
- Collegare solo moduli o combinazioni in serie di moduli con lo stesso voltage in parallel. If modules are connected in parallel, the total current is equal to the sum of the individual module or series combination currents.
- Utilizzare sempre lo stesso tipo di modulo all'interno di un determinato impianto fotovoltaico.
- If the sum of short circuit currents of the parallel-connected modules exceeds the reverse current, string diodes or fuses have to be used in each string of modules connected in parallel. These string diodes or fuses have to be qualified for the maximum expected current and voltage. The fuse rating value is also corresponds to the maximum reverse current that a module can withstand. The reverse current value can be found on the product label, in the product datasheet or in chapter 8 of the installation manual. Observe the instructions and safety precautions for all other components used in the system, including wiring and cables, connectors, DC-breakers, inverters, etc.
- Utilizzare attrezzature di sicurezza adeguate (utensili isolati, guanti dielettrici, scarpe, ecc.) approvate per l'uso su impianti elettrici.
CONFIGURAZIONE
- In condizioni normali, è probabile che un modulo fotovoltaico subisca condizioni che producono più corrente e/o volumetage than reported at Standard Test Conditions (STC: 1000 W/ m2, AM 1.5, and 250C/770F cell temperature) or Bifacial nominal power index(BNPl front irradiance 1000 W/m2, back irradiance 135 W/m2 AM 1.5, and 25 OC/770F cell temperature). The short-circuit current (ISC) should be multiplied by a factor of 1.25 and the open-circuit voltage (VOC) deve essere moltiplicato per un fattore fino a 1.25 in base alla temperatura ambiente minima e massima registrata per il luogo di installazione durante la determinazione del componente voltage, valori nominali della corrente del conduttore, dimensioni dei fusibili e dimensioni dei controlli collegati all'uscita FV.
- VoltagSono additivi quando i moduli FV sono collegati direttamente in serie e le correnti dei moduli sono additivi quando i moduli FV sono collegati direttamente in parallelo. I moduli fotovoltaici con caratteristiche elettriche diverse non devono essere collegati direttamente in serie. L'utilizzo di idonei dispositivi elettronici di terze parti collegati ai moduli fotovoltaici può consentire diversi collegamenti elettrici e deve essere installato secondo le istruzioni specificate dal produttore.
- Il volume massimotage of serial interconnection of the modules must be less than the maximum certified module’s system voltage. Inoltre, l'input massimo voltage dell'inverter e degli altri dispositivi elettrici dell'impianto devono essere tenuti in considerazione. Il circuito aperto voltage of the array string needs to be calculated at the lowest expected a mbient temperature forthe location. The maximal system voltage for the module is indicated in the module’s datasheet.
- Accordingly, for BLACKSTAR, SOLID or MAGNUS series modules, the values of ISC and VOC under STC or BNPI marked on this module should be multiplied by a factor of 1,25 when determining component voltage ratings, conductor current ratings, fuse sizes, and size of controls connected to the PV output. In the USA, referto Section 690-8 of the National Electrical Code (N EC) for an additional multiplying factor of 125 percent (80 percent de-rating) which may be applicable.
DISPOSITIVO DI PROTEZIONE DA SOVRACORRENTE (OCPD)
- When the potential reverse current of a PV string exceeds the rated SoliTek PV module series fuse rating (values indicated at the module datasheet) an overcurrent protection device (OCPD) must be used.
- An overcurrent protection device is required for each series string if more than two series are connected in parallel.
- In this case, it is needed to use one fuse per string rated at 1.25 x Isc or higher (Isc is the PV module’s short circuit current at STC). A PV fuse on each PV string will protect the PV modules and conductors from overcurrent faults and help minimize any safety hazards.
- The PV fuse will also isolate the faulted PV string so the balance of the PV system can continue to generate electricity.
- Fusibile amp valutazione ≥ 1.25 x Isc
- Selezionare la successiva classificazione standard superiore nel catalogo dei fusibili FV disponibili.
- Isc = Corrente di cortocircuito di un modulo in condizioni di prova standard (STC).
- Considerando i valori di Isc dei moduli SoliTek, il valore corretto dei fusibili FV da utilizzare nell'installazione è 30 A. SoliTek consiglia di utilizzare fusibili FV sia nel conduttore positivo che in quello negativo.
CAVI E CABLAGGI
I moduli fotovoltaici SoliTek sono forniti con due cavi di uscita standard resistenti alla luce solare che terminano con connettori fotovoltaici pronti per la maggior parte delle installazioni. Il terminale positivo (+) ha un connettore maschio mentre il terminale negativo (-) ha un connettore femmina. Il cablaggio del modulo è previsto per collegamenti in serie (ovvero, interconnessioni da maschio (+) a femmina (-)), ma può essere utilizzato anche per collegare dispositivi elettrici di terze parti idonei che possono avere configurazioni di cablaggio alternative purché vengano seguite le istruzioni del produttore.
Utilizzare un cablaggio sul campo con sezioni trasversali adeguate, approvate per l'uso con la massima corrente di cortocircuito del modulo fotovoltaico. Tutti i cablaggi devono essere cavi reticolati a doppio isolamento con una tensione nominale minima di 1,8 kV (oltre 1500 V voltage) e una temperatura nominale minima di 90 ˚C (190 °F). Sezione del filo non inferiore a 4 mm² (12 AWG). Il tipo di isolamento deve essere appropriato per il tipo di metodo di installazione utilizzato e deve soddisfare i requisiti IEC 61730 e Classe di sicurezza II.
- Livello di isolamento: 1,8 kV (conduttore-conduttore).
- Temperatura: almeno da -40°C a +90°C (da -40 °F a 190 °F).
- Costruzione del conduttore: filo di rame trefolato stagnato con purezza del rame superiore al 99,9%.
- Isolamento primario: polietilene reticolato (XLPE), resistente alla luce solare e all'umidità, ignifugo. Adatto per tubi e canaline installate nel sottosuolo.
- Isolamento (giacca): termoplastico, resistente alla luce solare, ignifugo, resistente all'acqua.
- Diametro esterno minimo del cavo con isolamento – 5,2 mm (2,05 pollici).
- Sezione trasversale minima del conduttore – 4 mm² (12 AWG).
SoliTek consiglia agli installatori di utilizzare solo cavi resistenti alla luce solare idonei per il cablaggio in corrente continua (CC) negli impianti fotovoltaici. I cavi devono essere fissati alla struttura di montaggio in modo tale da evitare danni meccanici al cavo e/o al modulo. Non sottoporre i cavi a sollecitazioni. Per il fissaggio, utilizzare mezzi appropriati, come fascette per cavi resistenti alla luce solare e/o clip per la gestione dei cavi. Sebbene i cavi siano resistenti alla luce solare e impermeabili, ove possibile, evitare l'esposizione diretta alla luce solare e l'immersione in acqua dei cavi.
La lunghezza standard dei cavi dalle scatole di giunzione è di 1,2 m (47,24 pollici). È previsto che due pannelli si interconnettano nel sistema.
MESSA A TERRA
- Module grounding must be done in accordance with the electrical design and construction specifications, procedures, regulations and other special grounding requirements applicable to the installation sites. If grounding is needed, it should be done accordingly:
Framed type modules grounding
I fori contrassegnati con un segno di messa a terra sul telaio possono essere utilizzati solo per la messa a terra. Non praticare ulteriori fori di messa a terra sul telaio del modulo.
The grounding conductor or strap may be copper, copper alloy, or any other material acceptable foruse as an electrical conductor in accordance with local electric codes and regulations.
Il conduttore di terra deve quindi effettuare un collegamento a terra utilizzando un elettrodo di terra idoneo.
A bolted connection is required; it incorporates:
- Una dimensione del bullone di M4.
- Una rondella dentata sotto la testa del bullone o un bullone seghettato devono penetrare rivestimenti non conduttivi come il telaio anodizzato.
- Un dado di fissaggio adatto al bullone M4.
- Tutto l'hardware dovrà essere in metallo non ferroso, acciaio inossidabile serie 300 o adeguatamente protetto dalla corrosione.
- La coppia consigliata per il bloccaggio del dado è 2 Nm÷2.2 Nm (1,48÷1,62 ft-lb).
- Il bullone di messa a terra deve passare attraverso tutti gli elementi di collegamento.

- I dispositivi elencati e identificati per la messa a terra dei telai metallici dei moduli fotovoltaici possono mettere a terra i telai metallici esposti del modulo a strutture di montaggio messe a terra.
- In any case the grounding screws or other parts have to be used separately from the mounting parts of the module.
- Alternate grounding options built through the mounting system are acceptable as long as they have been IEC and UL approved.
- Grounding resistance of the grounding structure shall be reached according to local regulations, Eurocodes, or other legal normative references.
Frameless type modules grounding
- Due to that modules are without frame, grounding is not forseen. Other PV plant equipment should be grounded according to the local and national electrical codes.
CONNETTORI
- Connectors for SoliTek PV panels are Stäubli MC4-Evo 2. Keep connectors dry and clean and ensure that connector caps are hand-tight before connecting the modules.
- Non tentare di effettuare un collegamento elettrico con connettori bagnati, sporchi o comunque difettosi.
- Evitare l'esposizione alla luce solare e l'immersione in acqua dei connettori. Evitare che i connettori siano appoggiati sul terreno o sulla superficie del tetto.
- Do not disconnect under load. Faulty connections can result in arcs and electrical shock.
- Verificare che tutti i collegamenti elettrici siano fissati saldamente. Assicurarsi che tutti i connettori di bloccaggio siano completamente inseriti e bloccati.
DIODI DI BYPASS
The PV module’s junction box contains 3 bypass diodes (one in each part of split junction box; Schottky type) connected in parallel with the PV cell strings. In the case of partial shading (hot-spot effect), the diodes bypass the current generated by the non-shaded cells, therebylimiting module heating and performance losses.
I diodi di bypass non sono dispositivi di protezione da sovracorrente. I diodi di bypass deviano la corrente dalle stringhe di celle in caso di ombreggiamento parziale. Le caratteristiche di questi diodi:
- Voltage valutazione – 50 V.
- Valutazione attuale – 25 A.
CLASSIFICAZIONE DELLA CLASSE DI ANTINCENDIO
- I moduli SoliTek SOLID Bifacial e Blackstar hanno superato il test antincendio IEC e hanno ottenuto la Classe di infiammabilità A. Il test antincendio è stato eseguito con un'inclinazione di 127 mm (5 pollici) per 300 mm (11,81 pollici), come prescritto nel punto A.2.5 della norma IEC 61730-2.
- SoliTek SOLID Bifacial has fire rating of 28 according to UL1703-2 standard. SoliTek Blackstar has fire rating of 29 according to UL1703-2 standard.
Montaggio meccanico
- The mechanical loads described in this manual are the test loads.
- For calculating the equivalent maximum design loads, a safety factor of 1.5 (Design load×1.5 safety factor=Mechanical test load) needs to be considered in compliance with the requirements of the local laws and regulations.
REQUISITI GENERALI
- Modules can be mounted in landscape or portrait orientation. For the bifacial modules, in order to get notable bifacial gain, the distance between the bottom of the modules and the roof or ground surface shall be at least 0,8 m (31,50 inch).
- Also, the bifacial gain increases significantly if modules are installed above white, light-reflecting surfaces (under surfaces with high albedo value).
- If the mounting rails are installed across the module, the bifaciality effect will be lower due to back-side cells shading.
- Si prega di osservare le norme di sicurezza e le istruzioni di installazione allegate al sistema di montaggio. Se necessario, contattare direttamente il fornitore per ulteriori informazioni.
- The modules must be safely set onto the mounting rail.
- The whole rail supporting the photovoltaic system must be strong enough to resist potential mechanical pressures caused either by wind or snow, in accordance with local, regional and state safety (and other associated) standards.
- The mounting system shall be tested and inspected by a third-party testing institution with static mechanical analysis capacity in accordance with local national standards or international standards.
- Before installing modules on a roof, ensure that the roof construction is suitable.
- In addition, any roof penetration required to mount the modules must be properly sealed to prevent leaks.
- Assicurarsi che la guida di montaggio non si deformi o influisca sui moduli quando si espande a causa dell'espansione termica.
- The module can appear thermal expansion and cold contraction; thus, the interval between two adjoining modules shall be no lesser than 10 mm (0,39 inch).
- Non tentare di praticare fori nella superficie del vetro e nei telai dei moduli poiché ciò invaliderà la garanzia.
- The mounting method must not result in the direct contact of dissimilar metals with the aluminum frame of the modules that will result in galvanic corrosion.
I componenti di montaggio devono essere realizzati con materiali durevoli, anticorrosivi e resistenti ai raggi UV (si consigliano componenti in acciaio inossidabile e alluminio anodizzato).
MONTAGGIO CON CLAMPS
- Utilizzare minimo 4 laminati clamps per fissare i moduli sulle guide di montaggio. Moduli clamps le parti metalliche non devono entrare in contatto con il vetro anteriore o posteriore. Quando si sceglie questo tipo di clamp-metodo di montaggio, utilizzare almeno quattro clamps su ciascun modulo; due clamps dovrebbe essere attaccato su ciascun lato lungo. A seconda dei carichi locali di vento e neve, clamps può essere necessario per garantire che i moduli possano sopportare il carico.
- ClampLa coppia di serraggio deve essere di almeno 15 Nm (11,06 ft-lb), ma non superiore a 20 Nm (14,75 ft-lb). Solitamente, 15 Nm (11,06 ft-lb) si raggiungono quando due profiles si toccano. Quando un modulo è installato in orientamento verticale su un tetto spiovente con pendenza >45°, è necessario un gancio aggiuntivo nella parte inferiore del modulo.

SOLID Black, Semi-clear, Satin, Agro Frameless
Con guide trasversali


BLACKSTAR, SOLID Black 35(40) mm, SOLID Semi-clear 35(40) mm, SOLID Satin 35(40) mm, SOLID Agro 35(40) mm, Magnus Framed mounting
- Quando si sceglie questo tipo di clamp-metodo di montaggio, utilizzare almeno quattro clamps su ciascun modulo; due clamps devono essere attaccati su ogni lato del modulo. Moduli clamps non deve entrare in contatto con il vetro frontale e non deve deformare il telaio.
- Assicurarsi di evitare effetti d'ombra sulle celle solari del modulo clamps.
- The module frame is not to be modified under any circumstances. Do not to block the drain hole of the frame.
- La lunghezza di clamp should be at least 30 mm (1,18 inch).
- il clamp deve sovrapporsi al telaio del modulo di almeno 5 mm (0,2 pollici), ma non più di 10 mm (0,4 pollici).
Con guide trasversali

Senza guide trasversali o guide perpendicolari al telaio laterale lungo

Con sistema di inserimento

Montaggio con bulloni
- Il modulo deve essere fissato e supportato da quattro bulloni M8 in acciaio inossidabile attraverso i fori di montaggio indicati sulle barre trasversali. Coppia di serraggio sul clamp bolt has to be in range of 8÷10 Nm (5,9÷7,38 ft-lb). The transversal bars positioning is shown in Figure 3.
- If additional mounting points are required, depending on the local wind and snow loads, then a mounting solution with clampÈ necessario scegliere l'hardware.

- Mounting with bolts can be done only through dedicated predrilled holes in the frame.
- È vietato praticare nuovi fori e invaliderà la garanzia.

POSIZIONE DELLA SCATOLA DI GIUNZIONE
- Per la distanza tra la scatola di giunzione e il bordo del modulo o altre dimensioni della posizione e delle aree della scatola di giunzione, fare riferimento alle figure riportate di seguito.

MANUTENZIONE
- Per garantire prestazioni ottimali del modulo, SoliTek consiglia quanto segue:
- Se necessario, il vetro frontale del modulo può essere pulito con acqua e una spugna o un panno morbido.
- Per rimuovere le macchie più ostinate è possibile utilizzare un detergente delicato e non abrasivo.
- Controllare periodicamente i collegamenti elettrici e meccanici e assicurarsi che siano puliti, sicuri, completi e protetti.
- In caso di problemi, consultare una persona autorizzata/qualificata.
SPECIFICHE
| Parametro \ Modello | STELLA NERA B.96 | SOLID Black (Semi-Clear) B.96 35(40) mm | STELLA NERA Satin B.96 | MAGNUS B.108 |
| Condizioni di prova | STC | STC | STC | STC |
| Potenza nominale | 455 L | 455 L | 445 L | 510 L |
| Dati elettrici @STC | ||||
| Potenza massima (Pmax), W | 455 | 455 | 445 | 510 |
| Voltage alla massima potenza (Vmpp), V | 29,71 | 29,71 | 29,40 | 33,34 |
| Corrente alla massima potenza (Ipp), A | 15,31 | 15,31 | 15,14 | 15,30 |
| Circuito aperto Voltage (Voc), V | 34,82 | 34,82 | 34,40 | 39,06 |
| Corrente di cortocircuito (Isc), A | 15,97 | 15,97 | 15,79 | 15,95 |
| Dati termici | ||||
| Intervallo di temperatura di esercizio | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) |
| Coefficiente di temperatura di Pmax | -0,362%/°C (°F) | -0,362%/°C (°F) | -0,362%/°C (°F) | -0,362%/°C (°F) |
| Coefficiente di temperatura di Voc | -0,265%/°C (°F) | -0,265%/°C (°F) | -0,265%/°C (°F) | -0,265%/°C (°F) |
| Coefficiente di temperatura di Isc | +0,036% /°C (°F) | +0,036% /°C (°F) | +0,036% /°C (°F) | +0,036% /°C (°F) |
| Dati su dimensioni e peso | ||||
| Lunghezza | 1762 millimetri | 1762 millimetri | 1762 millimetri | 1961 millimetri |
| Larghezza | 1134 millimetri | 1134 millimetri | 1134 millimetri | 1134 millimetri |
| Spessore | 30 millimetri | 35(40) mm | 30mm | 30 millimetri |
| Peso | 25,5 kg | 35 (36) kg | 25,5 kg | 28,5 kg |
| Metodo di montaggio | ||||
| Reference to the chapter | 3.3 | 3.3 | 3.3 | 3.3 |
| Altro | ||||
| Massima corrente inversa, A | 30 | |||
| Fire class, IEC 61730/UL 61730 | A/Tipo II | |||
| Volume massimo del sistematage, v | 1500 | |||
Table 9. Electrical and mechanical parameters table.
| Parametro \ Modello | SOLIDO Semi- clear B.96 | SOLID Black B.96 | SOLIDO Satin B.96 | SOLIDO Agro B.64 |
| Condizioni di prova | STC | STC | STC | STC |
| Potenza nominale | 455 L | 455 L | 445 L | 300 L |
| Dati elettrici @STC | ||||
| Potenza massima (Pmax), W | 455 | 455 | 445 | 300 |
| Voltage alla massima potenza (Vmpp), V | 29,71 | 29,71 | 29,40 | 19,60 |
| Corrente alla massima potenza (Ipp), A | 15,31 | 15,31 | 15,14 | 15,31 |
| Circuito aperto Voltage (Voc), V | 34,82 | 34,82 | 34,40 | 22,76 |
| Corrente di cortocircuito (Isc), A | 15,97 | 15,97 | 15,79 | 15,97 |
| Dati termici | ||||
| Intervallo di temperatura di esercizio | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) |
| Coefficiente di temperatura di Pmax | -0,30%/°C (°F) | -0,30%/°C (°F) | -0,30%/°C (°F) | -0,30%/°C (°F) |
| Coefficiente di temperatura di Voc | -0,25%/°C (°F) | -0,25%/°C (°F) | -0,25%/°C (°F) | -0,25%/°C (°F) |
| Coefficiente di temperatura di Isc | +0,045% /°C (°F) | +0,045% /°C (°F) | +0,045% /°C (°F) | +0,045% /°C (°F) |
| Dati su dimensioni e peso | ||||
| Lunghezza | 1772 ± 2 mm | 1772 ± 2 mm | 1772 ± 2 mm | 1772 ± 2 mm |
| Larghezza | 1144±2 | 1144±2 | 1144 ± 2 mm | 1144 ± 2 mm |
| Spessore | 7,2 millimetri | 7,2 millimetri | 7,2 millimetri | 7,2 millimetri |
| Peso | 33 kg | 33 kg | 33 kg | 33 kg |
| Metodo di montaggio | ||||
| Reference to the chapter | 3.2 | 3.2 | 3.2 | 3.2 |
| Altro | ||||
| Massima corrente inversa, A | 30 | |||
| Fire class, IEC 61730/UL 61730 | A/Tipo II | |||
| Volume massimo del sistematage, v | 1500 | |||
Table 10. Electrical and mechanical parameters table.
| Parametro \ Modello | SOLID Satin B.96 35 mm | SOLID Satin B. 96 40 millimetri | SOLID AgroB.64 35 mm | SOLID AgroB.64 40 mm |
| Condizioni di prova | STC | STC | STC | STC |
| Potenza nominale | 445 L | 445 L | 300 L | 300 L |
| Dati elettrici @STC | ||||
| Potenza massima (Pmax), W | 445 | 445 | 300 | 300 |
| Voltage alla massima potenza (Vmpp), V | 29,40 | 29,40 | 19,60 | 19,60 |
| Corrente alla massima potenza (Ipp), A | 15,14 | 15,14 | 15,31 | 15,31 |
| Circuito aperto Voltage (Voc), V | 34,40 | 34,40 | 22,78 | 22,78 |
| Corrente di cortocircuito (Isc), A | 15,79 | 15,79 | 15,97 | 15,97 |
| Dati termici | ||||
| Intervallo di temperatura di esercizio | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) |
| Coefficiente di temperatura di Pmax | -0,362%/°C (°F) | -0,362%/°C (°F) | -0,30%/°C (°F) | -0,30%/°C (°F) |
| Coefficiente di temperatura di Voc | -0,265%/°C (°F) | -0,265%/°C (°F) | -0,25%/°C (°F) | -0,25%/°C (°F) |
| Coefficiente di temperatura di Isc | +0,036% /°C (°F) | +0,036% /°C (°F) | +0,045% /°C (°F) | +0,045% /°C (°F) |
| Dati su dimensioni e peso | ||||
| Lunghezza | 1762mm | 1762mm | 1762 millimetri | 1762 millimetri |
| Larghezza | 1134 millimetri | 1134 millimetri | 1134 millimetri | 1134 millimetri |
| Spessore | 35 millimetri | 40 millimetri | 35 millimetri | 40 millimetri |
| Peso | 35 kg | 36 kg | 35 kg | 36 kg |
| Metodo di montaggio | ||||
| Reference to the chapter | 3.3 | |||
| Altro | ||||
| Massima corrente inversa, A | 30 | |||
| Fire class, IEC 61730/UL 61730 | A/Tipo II | |||
| Volume massimo del sistematage, v | 1500 | |||
Table 11.Electrical and mechanical parameters table.
- The electrical characteristics are within of the indicated values of ISC (φISC) ±3%, VOC (ϕVOC) ±3,5% and PMPP (ϕPmax) ±5%, under Standard Test Conditions (STC) (irradiance of 1000 W/m²,AM 1.5 spectrum, and a cell temperature of 25°C / 77°F)
- Tutti i pannelli SoliTek SOLID PV corrispondono alla classe di sicurezza elettrica II.
Esclusione di responsabilità
- Poiché è impossibile per SoliTek controllare l'installazione, il funzionamento, l'applicazione e la manutenzione dell'impianto fotovoltaico secondo queste istruzioni. SoliTek non si assume alcuna responsabilità e declina espressamente qualsiasi responsabilità per eventuali perdite, danni o spese derivanti da o in qualsiasi modo connessi a tale installazione, funzionamento, uso o manutenzione.
- SoliTek will not take any responsibility for any possible violation of patent rights and third-party rights that are related to the application of the solar energy system. No permission of patents is given through implication.
- The information of this instruction is from the knowledge and experiences of SoliTek. However, the instructions and suggestions of this instruction do not make an external or internal of guarantee. SoliTek reserves the right to revise this instruction, products and all the information about products without prior notification to customers.
Domande frequenti
- Q: What should I do before installing the PV modules?
- A: Read this entire guide, understand all instructions, and ensure compliance with all local, state, and federal regulations. Consult a certified building specialist for the structural integrity of the dwelling.
- Q: Can I install the PV modules myself without professional training?
- A: This documentation is not a complete installation manual for personnel not specifically trained in PV-modules. It serves as a general but strictly mandatory reference for the installer. Professional installation is highly recommended.
- Q: What happens if I don’t follow the instructions in this guide?
- A: Failure to follow instructions may damage system components, endanger personnel, damage property, or invalidate the panel warranty.
- Q: Is it safe to work on a rooftop during installation?
- A: Do not attempt to work on a rooftop until safety precautions have been identified and taken, including fall protection measures, ladders or stairways, and personal protective equipment (PPE). Avoid adverse conditions like strong winds or wet/frosted roofs.
- Q: How should I store the PV modules before installation?
- A: Store pallets in a cool and dry location until the PV modules are ready to be unpackaged. Do not exceed the maximum stacking height indicated on the packaging.
Documenti / Risorse