  • Use the buttons on the controller for various functions such as switching display parameters, increasing or decreasing parameter values, and setting PWM parameters.
  • Set the ‘L**’ Accelerated Temperature, ‘H**’ Full Speed Temperature, and ‘C**’ Shutdown Temperature to control the fan speed based on temperature thresholds.
  • Configure the PWM output time sequence by pressing the ‘OK’ button and using the ‘+’ and ‘-‘ buttons to switch between values P1 or P-1.

Regolatore di temperatura della ventola PWM a 12 fili DC 4V

Descrizione

  • It is a DC 12V 4-Wire PWM Fan Temperature Controller. 3Bit red LED digital display screen shows temperature and speed which can be used for Host box, CPU, Server host, etc.

Caratteristiche

  1. 4-Wire Fan Dedicated Controller
  2. 100% PWM Speed Control
  3. Support Reverse Time Sequence Fan
  4. Support 3A Fan Low Temperature Shutdown
  5. Temperature and Speed Dual Display
  6. Power-OFF Parameter Memory Function

Parametri

  • Volume di lavorotage: DC 8V-16V ( Recommend 12V)
  • Working Current: <40mA at 12V
  • Drive Current: <3.5A
  • PWM Range: 1%~100% (+/-0.5% )
  • Frequenza PWM: 25 KHz (+/-1 KHz)
  • Movimentazione continua Amptensione: 5 V a vuoto
  • Measure Temperature: -9.9C~99.9C Celsius Degree
  • Temperature Error : +/-1.2C at 0C~50C and +/-2C at others
  • Sensore di temperatura: NTC 10K B=3590 Sensore
  • Sensor Length : 40cm
  • Dimensioni del modulo: 60 * 29 * 21 mm

Button Set Method

  1. ’ + ’ Button : Switch display parameters at Normal Running State; Increase parameter value at Parameter Set State. Keep press to increase parameter values quickly and continuously at Parameter Set State.
  2. ’ – ’ Button : Switch display parameters at Normal Running State; Decrease parameter value at Parameter Set Mode. Keep press to decrease parameter values quickly and continuously at Parameter Set State.
  3. ’ OK ’ Button :
    1. >.At Normal Running State: Short-press enter into Set PWM Parameter State. Then press ‘ + ’ and ‘ – ’ buttons to change the parameter value and set range is 1% to 100%. Short-press again to save value and exit.
    2. >.At Normal Running State: Keep press 2 second enter into Set Temperature State. Then short-press press ‘ OK ’ button to switch parameters ‘ L** ’, ‘ H** ’, ‘ C** ’. Press ‘ + ’ and ‘ – ’ buttons to change the parameter value. Short press ‘ OK ’ button again to save value and exit.
    3. >.Set PWM OUT Time Sequence: Keep pressing ‘ OK ’ button and then turn ON the working power supply, then enter into set mode for PWM OUT Time Sequence. Press the‘ + ’ and ‘ – ’ buttons to switch the value of P1 or P-1. Press ‘ OK ’ button again to save value and exit.
      1. >. P1 : Forward Output, Default Normal PWM OUT Time Sequence.
      2. >. P-1: Reverse PWM OUT Time Sequence.

Temperature Parameter Set

  1. ‘ L** ’ Accelerated Temperature: Set range is 5~94. PWM output increases with temperature rise when the measured temperature higher than‘ L** ’.
  2. ‘ H** ’ Full Speed Temperature: Set range is 10~99. PWM keep output 100% and fan keeps running at full speed.
  3. ‘ C** ’ Shutdown Temperature:
    1. L'intervallo impostato è 0~92.
    2. Enable this function if ‘ C** ’ >0;
    3. Disable this function if this parameter is set to ‘ C00 ’. Fan keep work and PWM keep output.
    4. Turn OFF fan( both fan power and PWM signal are turn off) ;
    5. At Shutdown State: Fan restarts and speed changes with temperature if when the measured temperature higher than ‘ L** ’ Accelerated Temperature.
  4. Note-1: The difference between ‘ L** ’ Accelerated Temperature and ‘ H** ’ Full Speed Temperature cannot be less than 5.
  5. Note-2: The difference between ‘ L** ’ Accelerated Temperature and ‘ C** ’ Shutdown Temperature cannot be less than 2.
  6. Note-3: if the difference does not meet the requirements when setting parameters, the program will automatically adjust the other two parameters.

Applicazione

  1. Controllo dell'automazione industriale
  2. Macchina CNC
  3. Host box, CPU, Server host
  4. Regolatore di velocità

Pacchetto

  1. 1pcs DC 12V 4-Wire PWM Fan Temperature Controller
  2. 1pcs 40cm NTC 10K B=3590 Temperature Sensor

Domande frequenti

D: Qual è il volume di lavoro consigliato?tage per questo controller?

A: Il volume di lavoro consigliatotage is DC 12V, with a range of DC 8V-16V.

D: Come faccio a impostare la velocità della ventola in base alla temperatura?

A: You can set the L Accelerated Temperature, H Full Speed Temperature, and C Shutdown Temperature parameters to control the fan speed based on temperature thresholds.

Documenti / Risorse

Regolatore di temperatura della ventola PWM a 12 fili DC 4V Ubuy [pdf] Istruzioni
Regolatore di temperatura della ventola PWM a 12 fili da 4 V CC, Regolatore di temperatura della ventola PWM a 4 fili, Regolatore di temperatura della ventola PWM, Regolatore di temperatura

Riferimenti

Lascia un commento

Il tuo indirizzo email non verrà pubblicato. I campi obbligatori sono contrassegnati *