Controller di zona ZONEMIX4
“
Specifiche
- Supports up to 8 controllers per port
- Supports ONE audio input PER accessory port
- Supports up to 8 paging stations per port
- Maximum cable length per port: 100m – 500m depending on
accessori
Istruzioni per l'uso del prodotto
Step 1: Decide Port Wiring Layout
Decide if you need local audio inputs and allocate accessory
ports accordingly. One audio input can be used per port, while wall
controllers and paging stations can be connected to any port.
Step 2: Confirm Limits
Ensure you do not exceed the specified limits for cable length
and accessories per port as outlined in the provided table.
Step 3: Accessory Port Wiring
Follow the wiring guide provided for ZONEMIX and ZMPS wiring,
ensuring proper termination of cables to prevent signal
corruzione.
CABLAGGIO ZONEMIX E ZMPS
Follow the T-568A wiring diagram for proper connections of
signal, paging audio, RS485, +24V DC, GND, and local input.
WP4R, WP10, WPVOL Wiring & WPBT Wiring
Follow the wiring instructions provided for each accessory port
to ensure correct connection of paging audio, RS485, +24V DC, GND,
and remote input.
Istruzioni per la terminazione
- Terminate the ZONEMIX accessory ports based on which ports you
use using the PORT TERM switches. - Terminare l'accessorio LAST RS485 sul percorso cavi della porta.
Domande frequenti
Q: How many controllers can be connected per port?
A: The system supports up to 8 controllers per port.
Q: Can multiple wall panels and paging stations be connected on
the same accessory port?
A: Yes, multiple wall panels and paging stations can be
connected on the same accessory port.
“`
GUIDA AL CABLAGGIO
INTRODUZIONE
Le porte accessorie ZONEMIX consentono il collegamento di pannelli a parete, stazioni cercapersone e sorgenti di ingresso audio. Segui la guida qui sotto per configurare il tuo sistema.
Chiave:
Zonemix 4
Zonemix 8
Wall Controllers Audio Sources
Supporta fino a 8 controller per porta. (vedi pagina 2 per i dettagli)
Supporta UN ingresso audio PER porta accessori.
Supports up to 8 paging stations per port. (see page 2 for details) Note: Supports one active page at a time. Example setup: Lots of controllers, lots of paging stations and ONE audio input.
Si noti che i canali di ingresso audio locale della porta accessoria sono bloccati sulla zona di uscita corrispondente e può essere utilizzato solo uno per zona. Ad esempio, l'ingresso locale della porta accessori 1 si collega alla Zona 1. Tuttavia, è possibile collegare più pannelli a parete e stazioni cercapersone sulla stessa porta accessori.
www.australianmonitor.com.au
1
FASE 1: DECIDERE LA DISPOSIZIONE DEL CABLAGGIO DELLA PORTA
Do you need local audio inputs?
SÌ
NO
Utilizzare una porta accessoria per zona. cioè dalla porta 1 alla zona 1, dalla porta 2 alla zona 2 ecc. Poiché gli ingressi audio richiedono il proprio home run.
Only one audio input can be used per port. Wall controllers and paging stations can go on any port.
Use any port to any zone/s
FASE 2: CONFERMA DI NON SUPERARE I SEGUENTI LIMITI
Maximum cable length per port Accessories per port Maximum Accessories in system
100 metri
8
130 metri
7
180 metri
6
24
250 metri
5
400 metri
4
500 metri
3
The maximum distances quoted in the table are due to DC current limitations. The paging stations and wall panels can be locally powered to increase the cable length to a maximum
of 500m. Please read the following additional document: Advanced accessory port wiring guide.
www.australianmonitor.com.au
2
FASE 3: CABLAGGIO DELLA PORTA ACCESSORI
Wire the ZONEMIX and ZMPS paging stations as per the images below. · Category 5, 5e and 6 cabling supported. · T-568A wiring recommended. However, T-568B also supported.
ZONEMIX AND ZMPS WIRING 1
8
*T-568A wiring
1 2 3 4 5 6 7 8
Pin Colour 1 Green/White 2 Green 3 Orange/White 4 Blue 5 Blue/White 6 Orange 7 Brown/White 8 Brown
Zonemix
Signal Paging Audio + Paging Audio RS485 B +24V DC GND RS485 A Local Input + Local Input –
Zmps
CABLAGGIO DAISY CHAIN ZMPS
Zonemix
Use an RJ45 splitter or terminal block if daisy chain wiring required
www.australianmonitor.com.au
3
FASE 3: CABLAGGIO PORTA ACCESSORI (CONT.)
Wire the wall panels as per the images below. · Category 5, 5e and 6 cabling supported. · T-568A wiring recommended. However, T-568B also supported.
CABLAGGIO WP4R, WP10, WPVOL
CABLAGGIO WPBT
1
Audio cercapersone +
2
Audio cercapersone –
3
RS485A
4
+24V CC
5
Terra
6
RS485B
7
Ingresso remoto +
8
Ingresso remoto –
*Unused if not daisy chaining
Cablaggio a margherita
*Unused unless connecting to downstream ZMPS
Cablaggio a margherita
www.australianmonitor.com.au
4
STEP 4: PORT TERMINATION DO NOT SKIP THIS STEP
The ZONEMIX uses the RS485 standard to communicate to wall panels and paging stations. RS485 requires that each end of the cable run is terminated to prevent signal corruption due to signal reflections in the cable. The Accessory Ports are grouped in Pairs. 1+2, 3+4, 5+6, 7+8. You must terminate the ZONEMIX and Accessories based on which ports you use.
1. Terminate the ZONEMIX accessory ports, as per the table, using the PORT TERM switches
IMPOSTAZIONE INTERRUTTORE TERMINALE PORTA ACCESSORI
ONE PORT USED TERM BOTH PORTS USED TERM
Port 1 OR Port 2 used Port 3 OR Port 4 used
ON Port 1 AND Port 2 used OFF
ON
ON Port 3 AND Port 4 used OFF
Porta 5 OPPURE Porta 6 utilizzata
ON Port 5 AND Port 6 used OFF
Porta 7 OPPURE Porta 8 utilizzata
ON Port 7 AND Port 8 used OFF
2. Terminate the LAST RS485 accessory on the port cable run.
Terminazione della stazione cercapersone
Terminazione pannello a parete
Examples:
ONE port used:
PORT TERM = ON
Terminate end points
BOTH Ports used:
PORT TERM = OFF
www.australianmonitor.com.au
5
FASE 5: CABLAGGIO WP4R, WP10 GPO (OPZIONALE)
Il WP4R e il WP10 hanno entrambi 3 uscite per uso generale che possono essere controllate dai pulsanti del pannello a parete per attivare dispositivi esterni come i proiettori.
Schema dell'oggetto Criteri di gruppo
Ogni uscita è un transistor a collettore aperto. Vol. massimotage: 48 V Corrente massima dissipata: 250 mA
Example: Relay Connection
24V
Logica interna
Oggetto Criteri di gruppo1
Oggetto Criteri di gruppo2
Oggetto Criteri di gruppo3
www.australianmonitor.com.au
TERRA 6
Documenti / Risorse
![]() |
ZONEMIX ZONEMIX4 Zone Controller [pdf] Istruzioni ZONEMIX4, ZONEMIX4 Zone Controller, Zone Controller, Controller |