1. Introduzione
This manual provides essential information for the proper installation, operation, and maintenance of the Simplex 4090-9001 IAM Supervised IDNet Module. Please read this manual thoroughly before attempting to install or operate the device. Retain this manual for future reference.
2. Informazioni sulla sicurezza
AVVERTIMENTO: Installation and servicing of this device must be performed by qualified personnel only. Failure to follow these instructions could result in property damage, serious injury, or death. Always disconnect power before servicing.
- Rispettare tutti i codici e le normative elettriche locali e nazionali.
- Assicurare la corretta messa a terra e i collegamenti elettrici.
- Non utilizzare il dispositivo se appare danneggiato.
- Tenere lontano dall'umidità e dalle temperature estreme.
3. Prodotto finitoview
The Simplex 4090-9001 is an Individual Addressable Module (IAM) designed for use within a supervised IDNet system. It is housed in a durable thermoplastic casing, providing protection for its internal components. This module facilitates communication and supervision of connected devices within a fire alarm or security system.

Figura 3.1: Line drawing of the Simplex 4090-9001 IAM Supervised IDNet Module. This image shows the front view of the module with its label, indicating the model number and "SUPERVISED IAM" text.

Figura 3.2: The Simplex 4090-9001 module shown within its clear plastic packaging. The packaging includes a label with "PID: 4090-9001", "DESCRIPTION: IAM SUPERVISED IDNET", and "PART NUMBER: 0617952". Small resistors are also visible in the package.
4. Configurazione e installazione
The Simplex 4090-9001 module is designed for screw mount installation. Detailed installation instructions are provided in the separate document "INST. INSTR. 574-331", which typically accompanies the product. Always refer to this document for specific wiring diagrams and mounting procedures.
4.1. Controlli pre-installazione
- Verify that the module is the correct model (4090-9001) for your system.
- Inspect the module for any signs of physical damage.
- Ensure all necessary tools and additional components (e.g., screws, wiring) are available.
4.2. Montaggio
The module features a screw mount design. Select a suitable, secure location for mounting, ensuring it is free from excessive vibration, moisture, and extreme temperatures. Use appropriate fasteners for the mounting surface.
4.3. Cablaggio
The module utilizes screw-type connectors for wiring. Refer to the "INST. INSTR. 574-331" document for detailed wiring diagrams specific to your system configuration. Ensure all connections are secure and comply with applicable electrical codes. The module operates at 40 Volts.
5. Funzionamento
Once properly installed and connected to a compatible Simplex IDNet control panel, the 4090-9001 module functions as an interface for supervising and monitoring various devices. It communicates the status of these devices back to the control panel, allowing for centralized monitoring and response in a fire safety or security system. The module's operation is largely automatic once configured within the IDNet system.
6. Manutenzione
Regular maintenance is crucial to ensure the continued reliable operation of the Simplex 4090-9001 module and the overall fire safety system. It is recommended that a qualified technician perform periodic inspections and tests.
- Ispezione visiva: Periodically check the module and its wiring for any signs of damage, corrosion, or loose connections.
- Test di sistema: Follow the testing procedures outlined in your fire alarm system's documentation to ensure the module is communicating correctly with the control panel.
- Pulizia: If necessary, gently clean the exterior of the thermoplastic housing with a dry, soft cloth. Do not use abrasive cleaners or solvents.
7. Risoluzione Dei Problemi
If the Simplex 4090-9001 module is not functioning as expected, consider the following basic troubleshooting steps. For complex issues, contact qualified service personnel.
- Nessuna comunicazione:
- Verify all wiring connections are secure and correct according to "INST. INSTR. 574-331".
- Check power supply to the IDNet system.
- Ensure the module's address is correctly configured in the control panel.
- Indicazione di guasto:
- Consult your IDNet control panel's manual for specific fault codes and their meanings.
- Inspect the connected device(s) for faults.
- Danni fisici: If the module shows signs of physical damage, it should be replaced by a qualified technician.
8. Specifiche
| Caratteristica | Dettaglio |
|---|---|
| Numero di modello | 4090-9001 |
| Marca | Semplice |
| Descrizione | IAM Supervised IDNet Module |
| Materiale dell'alloggiamento | Thermoplastic (Plastic) |
| Colore | NERO |
| Dimensioni del prodotto | 8 x 8 x 4 pollici |
| Peso dell'articolo | 0.01 once |
| Voltage | 40 Volt |
| Tipo di connettore | Vite |
| Tipo di montaggio | Montaggio a vite |
| Codice UPC | 683194549410 |
9. Garanzia e supporto
Specific warranty information for the Simplex 4090-9001 module is typically provided at the point of purchase or can be obtained directly from Simplex or an authorized distributor. For technical support, service, or warranty claims, please contact your Simplex supplier or an authorized service center. Always provide the model number (4090-9001) and any relevant serial numbers when seeking support.
For further assistance, you may visit the official Simplex website or consult the documentation provided with your complete fire alarm system.